T-CAP All in One 185L DHW tank M Series 1 phase - 3 phase · R290
12kW
WH-WXG12ME5 + WH-ADC0316M3E52
T-CAP All in One 185L DHW tank M Series 1 phase - 3 phase · R290
Aquarea M Series, the latest generation of Aquarea air to water heat pumps with R290
Aquarea T‑CAP M Series delivers a revolution in the design, performance, connectivity, and sustainability.
The solution is suitable for both new buildings and retrofits, as it offers a sustainable alternative to traditional fossil fuel heating systems and it can be easily integrated with existing water system such as fan coils, floor heating or domestic hot water tanks.
- Up to 75°C water outlet down to -15°C outdoor
- Quiet operation: Only 29dB(A) sound pressure at 5 m*
- Reliable outdoor units with Panasonic compressor, operating down to -28°C outdoor
- T‑CAP technology: Keeping heating capacity down to -20°C
- Panasonic Comfort Cloud App and Aquarea Service Cloud included
- 2 CN-CNT connectivity ports
- Hydraulic connection between indoor and outdoor
- Maintenance free Inox stainless 185L tank
- All in One 599 x 602mm footprint reduces required installation space indoors
- No buffer tank required, reducing space, cost and installation time
- U-Vacua™ insulation panel for higher tank efficiency
- Also available with built-in impressed current anode (AN version)
* Sound pressure calculation for WH-WXG12ME5, free standing, A +7°C, W 35°C in Quite mode 3.
Further comfort and peace of mind with Aquarea
Specifications
| T-CAP All in One 185L DHW tank M Series 1 phase - 3 phase · R290 | |||
|---|---|---|---|
| 12 kW | |||
| Water volume | L | 185 | |
| Outdoor dimension (Depth) | mm | 430 | |
| Outdoor dimension (Width) | mm | 1.200 | |
| DHW tank ERP cold climate η | ηwh % | 88 | |
| DHW tank ERP warm climate η | ηwh % | 132 | |
| DHW tank ERP average climate η | ηwh % | 123 | |
| Tapping profile according EN16147 | L | ||
| Material inside tank | Stainless steel | ||
| Maximum water temperature | °C | 65 | |
| Elevation difference (in/out) | m | 30 | |
| Heating water flow (∆T=5 K. 35°C) | L/min | 34,4 | |
| A class pump (Input power Max) | W | 175 | |
| A class pump (Input power Min) | W | 30 | |
| A class pump (Number of speeds) | Variable speed | ||
| Heating cold climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A++ / A++ | |
| Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 4,31 / 3,26 | |
| Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 169 / 127 | |
| Heating warm climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A+++ | |
| Indoor unit 6kW electric heater | WH-ADC0316M6E52 | ||
| Outdoor sound power (Heat) (2) | dB(A) | 53 | |
| Indoor unit 9kW electric heater | — | ||
| Pipe length range maximum | m | 30 | |
| Pipe length range standard | m | 5 | |
| Water pipe connector (outdoor units) | Inch | 1¼ | |
| Water pipe connector (indoor units) | Inch | 1¼ | |
| Water pipe connector (shower) | Inch | 3/4 | |
| Water pipe connector (room) | Inch | 1¼ | |
| Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 6,47 / 4,34 | |
| Indoor unit 3kW electric heater | WH-ADC0316M3E52 | ||
| DHW tank ERP cold climate COPdHW | COPdHW | 2,20 | |
| DHW tank ERP warm climate COPdHW | COPdHW | 3,30 | |
| DHW tank ERP average climate COPdHW | COPdHW | 3,00 | |
| Operation range - outdoor temperature (Cool) | °C | +10 ~ +43 | |
| Operation range - outdoor temperature (Heat) | °C | -28 ~ +35 | |
| Water outlet (Cool) | °C | 5 ~ 20 | |
| Water outlet (Heat) | °C | 25 ~ 75 | |
| Heating capacity (A +7°C, W 35°C) | kW | 12,00 | |
| Indoor dimension (Height) | mm | 1.642 | |
| EER (A 35°C, W 7°C) | 3,61 | ||
| Cooling capacity (A 35°C, W 7°C) | kW | 9,00 | |
| COP (A -7°C, W 35°C) | 3,00 | ||
| Heating capacity (A -7°C, W 35°C) | kW | 12,00 | |
| COP (A +2°C, W 35°C) | 3,54 | ||
| Heating capacity (A +2°C, W 35°C) | kW | 12,00 | |
| COP (A +7°C, W 35°C) | 5,06 | ||
| Indoor net weight | kg | 89 | |
| COP (A +2°C, W 55°C) | 2,42 | ||
| Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 256 / 171 | |
| Heating average climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A++ | |
| Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 5,00 / 3,46 | |
| Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 197 / 135 | |
| EER (A 35°C, W 18°C) | 5,26 | ||
| Cooling capacity (A 35°C, W 18°C) | kW | 12,00 | |
| COP (A -7°C, W 55°C) | 2,17 | ||
| Heating capacity (A -7°C, W 55°C) | kW | 12,00 | |
| Heating capacity (A +2°C, W 55°C) | kW | 12,00 | |
| COP (A +7°C, W 55°C) | 3,23 | ||
| Heating capacity (A +7°C, W 55°C) | kW | 12,00 | |
| Outdoor unit | WH-WXG12ME5 | ||
| Indoor dimension (Depth) | mm | 602 | |
| Indoor dimension (Width) | mm | 599 | |
| Outdoor net weight | kg | 161 | |
| Outdoor dimension (Height) | mm | 1.520 | |
(1) Scale from A+++ to D.
(2) Sound power level in accordance to EN12102 under conditions of the EN14825.
(3) WH-WXG models are hermetically sealed.
(4) Check local regulations.
(5) Scale from A+ to F.
* EER and COP classification is at 230V only in accordance with EU directive 2003/32/EC.
** This product is designed to comply with the European drinking water standard (EU) 2020/2184. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.