2-Pipe ECOi EX MZ1 Series - R32

2-Pipe ECOi EX MZ1 Series R32

Extreme efficiency, quality, compact.



* Panasonic’s internal research. 12HP model with 30m piping installation.


Specifications

See all
2-Pipe ECOi EX MZ1 Series - R32 THREE PHASE
8 HP 10 HP 12 HP
Sound pressure (Cool silent 1) dB(A) 54 57 61
Current in heating (1p 230V / 3p 400) A 9,0,32 11,0,90 14,0,90
Current in heating (1p 240V / 3p 415) A 8,0,98 11,0,50 14,0,40
SCOP (5) 4,0,35 4,0,38 4,0,33
Air flow m³/min 209 209 209
External static pressure Pa 80 80 80
Starting current A 1,0,00 1,0,00 1,0,00
Piping diameter (Liquid) (2) Inch (mm) 3/8 (9,52) / 1/2 (12,70) 3/8 (9,52) / 1/2 (12,70) 3/8 (9,52) / 1/2 (12,70)
Piping diameter (Balance) (2) Inch (mm) 04/01/2000 04/01/2000 04/01/2000
Piping diameter (Gas) (2) Inch (mm) 3/4 (19,05) / 7/8 (22,22) 3/4 (19,05) / 7/8 (22,22) 7/8 (22,22) / 1-1/8 (28,58)
Maximum allowable indoor / outdoor capacity ratio (3) % 50 ~ 200 (130) 50 ~ 200 (130) 50 ~ 200 (130)
Sound power (Cool normal mode) dB(A) 75 77 81
Sound power (Heat normal mode) dB(A) 75 77 84
Sound pressure (Cool silent 1) dB(A) 54 57 61
Current in heating (1p 220V / 3p 380) A 9,0,81 12,0,50 15,0,70
Sound pressure (Cool silent 2) dB(A) 52 55 59
Sound pressure (Cool silent 2) dB(A) 52 55 59
Sound pressure (Cool silent 3) dB(A) 50 50 50
Sound pressure (Cool silent 3) dB(A) 50 50 50
ErP data (4) - - -
ErP data (4) - - -
ErP data (4) - - -
SEER (5) 7,0,27 7,0,82 7,0,37
SEER (5) 7,0,27 7,0,82 7,0,37
ηs,c 288,0,0% 310,0,1% 292,0,1%
ηs,c 288,0,0% 310,0,1% 292,0,1%
ηs,c 288,0,0% 310,0,1% 292,0,1%
ηs,h 171,0,0% 172,0,4% 170,0,3%
ηs,h 171,0,0% 172,0,4% 170,0,3%
ηs,h 171,0,0% 172,0,4% 170,0,3%
Operating range (Cool - Max) °C 52 52 52
Operating range (Cool - Min) °C -10 -10 -10
Cooling capacity (Nominal) kW 22,0,4 28,0,0 33,0,5
Heating capacity (Nominal) kW 25,0,0 31,0,5 37,0,5
Net weight kg 203 203 206
Refrigerant (R32) / CO2 Eq. kg / T 6,30 / 4,25 6,40 / 4,32 8,50 / 5,74
Outdoor unit U-8MZ1E8 U-10MZ1E8 U-12MZ1E8
Operating range (Heat - Min) °C -25 -25 -25
Operating range (Heat - Max) °C 24 24 24
COP (1) W/W 4,0,50 4,0,30 4,0,00
Dimension (Height) mm 1,660 1,660 1,660
Dimension (Width) mm 880 880 880
Dimension (Depth) mm 765 765 765
Power supply (Voltage) V 11/06/2245 11/06/2245 11/06/2245
Power supply (Phase) Three phase Three phase Three phase
Power supply (Frequency) Hz 50 50 50
EER (1) W/W 3,0,30 3,0,50 3,0,00
Input power cooling kW 6,0,78 8,0,00 11,0,1
Input power heating W 5,0,55 7,0,32 9,0,37
Current in cooling (1p 220V / 3p 380) A 11,0,70 13,0,50 18,0,30
Current in cooling (1p 230V / 3p 400) A 11,0,10 12,0,80 17,0,40
Current in cooling (1p 240V / 3p 415) A 10,0,70 12,0,40 16,0,80

1) EER and COP calculation is based in accordance to EN 14511.
2) Piping diameter under 100m for ultimate indoor unit / over 100m for ultimate indoor unit (if the longest piping equivalent length exceeds 100m, increase the sizes of the main tubes by 1 rank for gas tubes and liquid tubes).
3) If the following conditions are satisfied, the effective range is above 130% and below 200%: A. Obey the limited number of connectable indoor units. B. The lower limit of operating range for heating outdoor temperature is limited to -10°C WB (standard -25°C WB). C. Simultaneous operation is limited to less than 130% of connectable indoor units.
4) SEER / SCOP and ηs,c / ηs,h are in accordance with ErP test data for U2 type 4 way 90x90 cassette indoor units.
5) SEER / SCOP is calculated based on the seasonal space cooling / heating efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.