BZ super-compact · R32 SINGLE PHASE
2.5 kW 3.3 kW 5.0 kW 6.0 kW
Cooling capacity (Min) kW 0,85 0,85 0,98 0,98
Input power heating (Min) kW 0,19 0,2 0,21 0,23
COP (Max) (1) W/W 3,5 3,49 3,09 3,02
COP (Min) (1) W/W 4,21 4,1 4,67 4,26
Heating capacity (Max) kW 3,6 4,4 7,5 8
Heating capacity (Min) kW 0,8 0,8 0,98 0,98
Input power cooling (Max) kW 0,9 1,28 1,86 2,3
Input power cooling (Min) kW 0,21 0,24 0,25 0,25
EER (Max) (1) W/W 3,33 3,05 2,9 2,83
EER (Min) (1) W/W 4,05 3,54 3,92 3,92
Cooling capacity (Max) kW 3 3,9 5,4 6,5
Input power heating (Max) kW 1,03 1,26 2,43 2,65
Operating range (Heat - Max) °C 24 24 24 24
Operating range (Heat - Min) °C -15 -15 -15 -15
Operating range (Cool - Max) °C 43 43 43 43
Elevation difference (in/out) (6) m 15 15 15 15
Outdoor dimension (Depth) (5) mm 289 289 299  320
Outdoor dimension (Width) (5) mm 780 780 824  875
Outdoor dimension (Height) (5) mm 542 542 619 695
Outdoor sound pressure (Heat -Hi) (4) dB(A) 49 50 49 50
Outdoor unit CU-BZ25CKE CU-BZ35CKE CU-BZ50CKE CU-BZ60CKE
Outdoor air flow (Heat) m³/min 30,4 30,4 32,7 39,2
Outdoor air flow (Cool) m³/min 30,4 31,1 32,7 42,6
Indoor unit CS-BZ25CKE CS-BZ35CKE CS-BZ50CKE CS-BZ60CKE
Indoor sound pressure (Heat -Q-Lo) (4) dB(A) 24 25 34 34
Indoor sound pressure (Heat -Lo) (4) dB(A) 27  33  37  37 
Indoor sound pressure (Heat -Hi) (4) dB(A) 36  38  44  45 
Indoor sound pressure (Cool -Q-Lo) (4) dB(A) 20 20 34 34
Indoor sound pressure (Cool -Lo) (4) dB(A) 26  30  37  37 
Moisture removal volume L/h 1,5 1,9 2,8 3,3
Indoor air flow (Heat) m³/min 10,5 11,4 13,4 13,1
Indoor air flow (Cool) m³/min 10,0  10,4  12,6  12,8 
Indoor connection indoor / outdoor mm² 4x1,5 4x1,5 4x2,5 4x2,5
Indoor power source V 230 230 230 230
Annual energy consumption heating (3) kWh/a 668 800 1 333 1 502
Annual energy consumption cooling (3) kWh/a 135 178 265 328
Input power cooling (Nominal) kW 0,68 1,02 1,65 1,98
Pdesign (cooling) kW 2,5 3,3 5 6
SEER (2) 6,50 A++ 6,50 A++ 6,60 A++ 6,40 A++
Outdoor net weight kg 24 25 35 42
Outdoor sound pressure (Cool -Hi) (4) dB(A) 48 48 48 50
Indoor net weight kg 9 9 9 9
Indoor dimension (Height) mm 290 290 290 290
Indoor sound pressure (Cool -Hi) (4) dB(A) 37  38  44  45 
SCOP (2) 4,40 A+ 4,20 A+ 4,20 A+ 4,10 A+
Pipe length range m 3 ~ 15 3 ~ 15 3 ~ 15 3 ~ 30
Heating capacity at -7°C kW 2,35 2,6 4,62 5,19
Kit KIT-BZ25-CKE KIT-BZ35-CKE KIT-BZ50-CKE KIT-BZ60-CKE
Additional gas amount g/m 10 10 15 15
Pipe length for additional gas m 7,5 7,5 10 7,5
Pipe diameter (Gas) Inch (mm) 3/8 (9,52) 3/8 (9,52) 1/2 (12,70) 1/2 (12,70)
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Indoor dimension (Depth) mm  214  214  214  214
Indoor dimension (Width) mm  765  765  765  765
Indoor recommended fuse A 16 16 16 20
Refrigerant (R32) / CO2 Eq. kg / T 0,50 / 0,34 0,56 / 0,38 1,03 / 0,70 1,03 / 0,70
EER (Nominal) (1) W/W 3,68 3,24 3,03 3,03
COP (Nominal) (1) W/W 4,09 3,72 3,42 3,16
Heating capacity (Nominal) kW 3,15 3,7 5,4 6,8
Cooling capacity (Nominal) kW 2,5 3,3 5 6
Operating range (Cool - Min) °C -10 -10 -10 -10
Input power heating (Nominal) kW 0,77 1 1,58 2,15
Pdesign at -10°C kW 2,1 2,4 4 4,4

1) EER and COP calculation is based in accordance to EN14511.
2) Energy Label Scale from A+++ to D.
3) The annual energy consumption is calculated in accordance to EU/626/2011.
4) The sound pressure of the indoor unit shows the value measured of a position of 1m in front of the main body and 0,8m below the unit. For outdoor unit 1m in front and 1m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
5) Add 70mm for piping port.