Etherea with nanoe™ X Pure White Matt R32

Etherea with nanoe™ X technology

A smart solution to keep your home clean, comfortable and welcoming
The smart, new Etherea comes with nanoe™ X technology with the benefits of hydroxl radicals. With advanced control options, class-leading performance, a stylish design and intelligent features, Etherea is designed to make your home comfortable, clean and the ideal place to be.

Specifications

See all
Etherea with nanoe™ X Pure White Matt R32 SINGLE PHASE
2.1 kW 2.5 kW 3.5 kW 4.2 kW 5.0 kW 7.1 kW
Cooling capacity (Min) kW 0,75 0,85 0,85 0,85 0,98 0,98
Input power heating (Min) kW 0,16 0,16 0,18 0,19 0,23 0,40
COP (Max) (1) W/W 4,26 4,07 3,77 3,66 3,35 3,29
COP (Min) (1) W/W 4,69 5,00 4,44 4,21 4,26 2,45
Heating capacity (Max) kW 4,00 4,80 5,50 6,80 8,00 10,20
Heating capacity (Min) kW 0,75 0,80 0,80 0,80 0,98 0,98
Input power cooling (Max) kW 0,67 0,90 1,16 1,57 1,90 3,00
Input power cooling (Min) kW 0,16 0,17 0,20 0,24 0,25 0,42
EER (Max) (1) W/W 3,96 3,89 3,62 3,18 3,16 2,83
EER (Min) (1) W/W 4,69 5,00 4,25 3,62 3,92 2,33
Cooling capacity (Max) kW 2,65 3,50 4,20 5,00 6,00 8,50
Input power heating (Max) kW 0,94 1,18 1,46 1,86 2,39 3,10
Operating range (Heat - Max) °C 24 24 24 24 24 24
Operating range (Heat - Min) °C -15 -15 -15 -15 -15 -15
Operating range (Cool - Max) °C 43 43 43 43 43 43
Elevation difference (in/out) (6) m 15 15 15 15 15 20
Outdoor dimension (Depth) (5) mm 289 289 289 289 320 320
Outdoor dimension (Width) (5) mm 780 780 780 780 875 875
Outdoor dimension (Height) (5) mm 542 542 542 542 695 695
Outdoor sound pressure (Heat -Hi) (4) dB(A) 46 47 50 51 47 54
Outdoor unit CU-Z20XKE CU-Z25XKE CU-Z35XKE CU-Z42XKE CU-Z50XKE CU-Z71XKE
nanoe X Generator Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2
Outdoor air flow (Heat) m³/min 26,7 27,2 30,6 30,9 36,9 45,8
Outdoor air flow (Cool) m³/min 27,4 28,7 29,8 29,8 39,8 44,7
Indoor unit CS-Z20XKEW CS-Z25XKEW CS-Z35XKEW CS-Z42XKEW CS-Z50XKEW CS-Z71XKEW
Indoor sound pressure (Heat -Q-Lo) (4) dB(A) 19 19 19 29 30 30
Indoor sound pressure (Heat -Lo) (4) dB(A) 25 27 33 35 37 38
Indoor sound pressure (Heat -Hi) (4) dB(A) 38 41 43 43 44 47
Indoor sound pressure (Cool -Q-Lo) (4) dB(A) 19 19 19 25 30 30
Indoor sound pressure (Cool -Lo) (4) dB(A) 24 25 28 31 37 38
Moisture removal volume L/h 1,3 1,5 2,0 2,4 2,8 4,1
Indoor air flow (Heat) m³/min 13,0 14,1 14,7 15,4 19,1 19,9
Indoor air flow (Cool) m³/min 11,7 12,7 12,7 14,4 17,4 19,0
Indoor connection indoor / outdoor mm² 4 x 1,5 4 x 1,5 4 x 1,5 4 x 1,5 4 x 2,5 4 x 2,5
Indoor power source V 230 230 230 230 230 230
Annual energy consumption heating (3) kWh/a 613 646 754 1200 1225 1833
Annual energy consumption cooling (3) kWh/a 91,00 93,00 129,00 210,00 206,00 382,00
Input power cooling (Nominal) kW 0,45 0,51 0,85 1,24 1,36 2,24
Pdesign (cooling) kW 2,1 2,5 3,5 4,2 5 7,1
SEER (2) 8,10 A++ 9,40 A+++ 9,50 A+++ 7,00 A++ 8,50 A+++ 6,50 A++
Outdoor net weight kg 25 27 30 30 40 50
Outdoor sound pressure (Cool -Hi) (4) dB(A) 45 46 48 49 47 52
Indoor net weight kg 10 10 11 10 12 14
Indoor dimension (Height) mm 295 295 295 295 295 295
Indoor sound pressure (Cool -Hi) (4) dB(A) 37 39 42 43 44 47
SCOP (2) 4,80 A++ 5,20 A+++ 5,20 A+++ 4,20 A+ 4,80 A++ 4,20 A+
Pipe length range m 3 ~ 15 3 ~ 15 3 ~ 15 3 ~ 15 3 ~ 30 3 ~ 30
Heating capacity at -7°C kW 2,38 2,80 3,20 4,11 4,80 6,31
Kit KIT-Z20-XKE KIT-Z25-XKE KIT-Z35-XKE KIT-Z42-XKE KIT-Z50-XKE KIT-Z71-XKE
Additional gas amount g/m 10 10 10 10 15 25
Pipe length for additional gas m 7,5 7,5 7,5 7,5 7,5 10
Pipe diameter (Gas) Inch (mm) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 1/2 (12,70) 1/2 (12,70) 5/8 (15,88)
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Indoor dimension (Depth) mm 229 229 229 229 244 244
Indoor dimension (Width) mm 870 870 870 870 1040 1040
Indoor recommended fuse A 16 16 16 16 16 20
Refrigerant (R32) / CO2 Eq. kg / T 0,67 / 0,45 0,80 / 0,54 0,89 / 0,60 0,95 / 0,64 1,13 / 0,76 1,35 / 0,91
EER (Nominal) (1) W/W 4,56 4,90 4,12 3,39 3,68 3,17
COP (Nominal) (1) W/W 4,52 4,86 4,44 3,68 4,14 3,69
Heating capacity (Nominal) kW 2,80 3,40 4,00 5,30 5,80 8,20
Cooling capacity (Nominal) kW 2,05 2,50 3,50 4,20 5,00 7,10
Operating range (Cool - Min) °C -10 -10 -10 -10 -10 -10
Input power heating (Nominal) kW 0,62 0,70 0,90 1,44 1,40 2,22
Pdesign at -10°C kW 2,1 2,4 2,8 3,6 4,2 5,5

1) EER and COP calculation is based in accordance to EN14511.
2) Energy Label Scale from A+++ to D.
3) The annual energy consumption is calculated in accordance to EU/626/2011.
4) The sound pressure of the indoor unit shows the value measured of a position 1m in front of the main body and 0,8m below the unit. For outdoor unit 1m in front and 1m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
5) Add 70mm for piping port.
6) When installing the outdoor unit at a higher position than the indoor unit.