Stropna naprava PACi Elite • R32

Prejšnja zmogljivost Naslednja zmogljivost

Stropne enote zagotavljajo obsežno in široko razporeditev zraka, kar je odlično za velike prostore. Vse enote so enake višine in globine, tako da so ne glede na vrsto vgradnje enakega videza.

Tehnični podatki

Poglej vse
Stropna naprava PACi Elite • R32
5.0 kW
Kit KIT-50PT2ZH5
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 5,0
Cooling capacity (Min) kW 1,5
Cooling capacity (Max) kW 5,6
EER (Nominal) (1) W/W 4,17
SEER (2) 7,0 A++
Pdesign (cooling) kW 5,0
Input power cooling (Nominal) kW 1,20
Annual energy consumption cooling (3) kWh/a 250
Annual energy consumption cooling (3) kWh/a 250
Heating capacity (Nominal) kW 5,6
Heating capacity (Min) kW 1,5
Heating capacity (Max) kW 6,5
COP (Nominal) (1) W/W 4,34
SCOP (2) 4,6 A++
Pdesign at -10°C kW 4,5
Input power heating (Nominal) kW 1,29
Annual energy consumption heating (3) kWh/a 1370
Indoor unit S-50PT2E5B
Indoor air flow (Hi) m³/min 15,0
Indoor air flow (Med) m³/min 12,5
Indoor air flow (Lo) m³/min 10,5
Indoor sound pressure (Med) (4) dB(A) 33
Indoor sound pressure (Lo) (4) dB(A) 29
Indoor dimension (Height) mm 235
Indoor dimension (Width) mm 960
Indoor dimension (Depth) mm 690
Indoor net weight kg 27
Outdoor unit U-50PZH2E5
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 5,60
Current in cooling (1p 230V / 3p 400) A 5,35
Current in cooling (1p 240V / 3p 415) A 5,10
Current in heating (1p 220V / 3p 380) A 6,10
Current in heating (1p 230V / 3p 400) A 5,85
Current in heating (1p 240V / 3p 415) A 5,60
Outdoor air flow (Cool) m³/min 40
Outdoor air flow (Heat) m³/min 45
Outdoor sound pressure (Cool -Hi) dB(A) 45
Outdoor sound pressure (Heat -Hi) dB(A) 48
Outdoor sound power (Cool -Hi) dB(A) 64
Outdoor sound power (Heat -Hi) dB(A) 68
Outdoor dimension (Height) mm 695
Outdoor dimension (Width) mm 875
Outdoor dimension (Depth) mm 320
Outdoor net weight kg 43
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70)
Pipe length range m 3 ~ 40
Elevation difference (in/out) (5) m 30
Pipe length for additional gas m 30
Additional gas amount g/m 20
Refrigerant (R32) / CO2 Eq. kg / T 1,15 / 0,776
Operating range (Cool - Min) °C -15
Operating range (Cool - Max) °C 46
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C 24

(1) Izračun EER in COP je izdelan na podlagi EN14511.
(2) Lestvica energijskih nalepk od A+++ do D. Za modele z manj kot 12 kW sta vrednosti SEER in SCOP izračunani na podlagi vrednosti direktive EU/626/2011. Za modele z več kot 12 kW sta vrednosti SEER in SCOP izračunani na podlagi vrednosti direktive EU/2281/2016.
(3) Letna poraba energije je izračunana v skladu z direktivo EU/626/2011.
(4) Zvočni tlak enot prikazuje vrednost, izmerjeno 1 meter pred glavnim ohišjem in 1 meter pod enoto. Zvočni tlak je izmerjen v skladu s tehničnimi navedbami v dokumentu Eurovent 6/C/006-97.
(5) Pri nameščanju zunanje enote na višji položaj od notranje enote.
(6) Modeli 100–140PZH2E5(8) lahko v računalniških prostorih delujejo pri temperaturi do –20 °C z dolžino cevi 30 m ali manj.
* Priporočena jakost varovalke za notranjo enoto je 3 A.