Stropna naprava PACi Elite • R32

Stropne enote zagotavljajo obsežno in široko razporeditev zraka, kar je odlično za velike prostore. Vse enote so enake višine in globine, tako da so ne glede na vrsto vgradnje enakega videza.

Tehnični podatki

Poglej vse
Stropna naprava PACi Elite • R32
6.0 kW
Kit KIT-60PT2ZH5
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 6,0
Cooling capacity (Min) kW 2,0
Cooling capacity (Max) kW 7,1
EER (Nominal) (1) W/W 4,08
SEER (2) 7,2 A++
Pdesign (cooling) kW 6,0
Input power cooling (Nominal) kW 1,47
Annual energy consumption cooling (3) kWh/a 292
Annual energy consumption cooling (3) kWh/a 292
Heating capacity (Nominal) kW 7,0
Heating capacity (Min) kW 1,8
Heating capacity (Max) kW 8,0
COP (Nominal) (1) W/W 4,43
SCOP (2) 4,7 A++
Pdesign at -10°C kW 6,0
Input power heating (Nominal) kW 1,58
Annual energy consumption heating (3) kWh/a 1787
Indoor unit S-60PT2E5B
Indoor air flow (Hi) m³/min 20,0
Indoor air flow (Med) m³/min 17,0
Indoor air flow (Lo) m³/min 14,5
Indoor sound pressure (Med) (4) dB(A) 34
Indoor sound pressure (Lo) (4) dB(A) 30
Indoor dimension (Height) mm 235
Indoor dimension (Width) mm 1275
Indoor dimension (Depth) mm 690
Indoor net weight kg 33
Outdoor unit U-60PZH2E5
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 7,15
Current in cooling (1p 230V / 3p 400) A 6,85
Current in cooling (1p 240V / 3p 415) A 6,55
Current in heating (1p 220V / 3p 380) A 7,75
Current in heating (1p 230V / 3p 400) A 7,40
Current in heating (1p 240V / 3p 415) A 7,10
Outdoor air flow (Cool) m³/min 40
Outdoor air flow (Heat) m³/min 45
Outdoor sound pressure (Cool -Hi) dB(A) 46
Outdoor sound pressure (Heat -Hi) dB(A) 49
Outdoor sound power (Cool -Hi) dB(A) 65
Outdoor sound power (Heat -Hi) dB(A) 69
Outdoor dimension (Height) mm 695
Outdoor dimension (Width) mm 875
Outdoor dimension (Depth) mm 320
Outdoor net weight kg 44
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 3 ~ 40
Elevation difference (in/out) (5) m 30
Pipe length for additional gas m 30
Additional gas amount g/m 35
Refrigerant (R32) / CO2 Eq. kg / T 1,45 / 0,979
Operating range (Cool - Min) °C -15
Operating range (Cool - Max) °C 46
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C 24

(1) Izračun EER in COP je izdelan na podlagi EN14511.
(2) Lestvica energijskih nalepk od A+++ do D. Za modele z manj kot 12 kW sta vrednosti SEER in SCOP izračunani na podlagi vrednosti direktive EU/626/2011. Za modele z več kot 12 kW sta vrednosti SEER in SCOP izračunani na podlagi vrednosti direktive EU/2281/2016.
(3) Letna poraba energije je izračunana v skladu z direktivo EU/626/2011.
(4) Zvočni tlak enot prikazuje vrednost, izmerjeno 1 meter pred glavnim ohišjem in 1 meter pod enoto. Zvočni tlak je izmerjen v skladu s tehničnimi navedbami v dokumentu Eurovent 6/C/006-97.
(5) Pri nameščanju zunanje enote na višji položaj od notranje enote.
(6) Modeli 100–140PZH2E5(8) lahko v računalniških prostorih delujejo pri temperaturi do –20 °C z dolžino cevi 30 m ali manj.
* Priporočena jakost varovalke za notranjo enoto je 3 A.

Dopolnilni izdelki