Specifications

See all
K Generation 1 phase - 3 phase · R32 SINGLE PHASE THREE PHASE
9 kW 12 kW 9 kW 12 kW
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 256 / 171 256 / 171 256 / 171 256 / 171
Elevation difference (in/out) m 20 20 20 20
Outdoor dimension (Depth) mm 320 320 320 320
Outdoor dimension (Width) mm 900 900 900 900
Heating water flow (∆T=5 K. 35°C) L/min 25,8 34,4 25,8 34,4
A class pump (Number of speeds) Variable speed Variable speed Variable speed Variable speed
Water pipe connector Inch R 1¼ R 1¼ R 1¼ R 1¼
Indoor sound pressure (Cool) dB(A) 33 33 33 33
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,47 / 4,34 6,47 / 4,34 6,47 / 4,34 6,47 / 4,34
Operation range - Outdoor ambient (Heat) °C -28 ~ +35 -28 ~ +35 -28 ~ +35 -28 ~ +35
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A++ A++ / A++ A++ / A++ A++ / A++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,31 / 3,26 4,31 / 3,26 4,31 / 3,26 4,31 / 3,26
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 169 / 127 169 / 127 169 / 127 169 / 127
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,96 / 3,57 4,96 / 3,57 4,96 / 3,57 4,58 / 3,46
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 195 / 140 195 / 140 195 / 140 180 / 135
EER (A 35°C, W 18°C) 4,63 3,92 4,63 3,92
Cooling capacity (A 35°C, W 18°C) kW 8,80 10,70 8,80 10,70
Electric backup heater kW 3,00 — 6,00 6,00 3,00 — 9,00 9,00
Outdoor sound power (Heat) (2) dB(A) 65 65 65 65
Indoor unit 9kW electric heater WH-SXC09K9E8 WH-SXC12K9E8
Kit 9kW electric heater KIT-WXC09K9E8 KIT-WXC12K9E8
Recommended fuse A 30 / 15 or 16 — 30 / 30 30 / 30 20 / 15 or 16 — 20 / 20 20 / 20
Recommended minimum cable size, supply 2 (4) mm² 3x1,5 — 3x4,0 3x4,0 3x1,5 — 5x1,5 5x1,5
Recommended minimum cable size, supply 1 (4) mm² 3x4,0 — 3x4,0 3x4,0 5x1,5 — 5x1,5 5x1,5
COP (A -7°C, W 55°C) 2,10 2,29 2,10 2,29
Electrical information 3kW — 6kW 6kW 3kW — 9kW 9kW
Indoor unit 6kW electric heater WH-SXC09K6E5 WH-SXC12K6E5
Indoor unit 3kW electric heater WH-SXC09K3E5 WH-SXC09K3E8
Kit 6kW electric heater KIT-WXC09K6E5 KIT-WXC12K6E5
Kit 3kW electric heater KIT-WXC09K3E5 KIT-WXC09K3E8
Water outlet (Heat) (3) °C 20 ~ 60 20 ~ 60 20 ~ 60 20 ~ 60
Operation range - Outdoor ambient (Cool) °C +10 ~ +43 +10 ~ +43 +10 ~ +43 +10 ~ +43
COP (A +7°C, W 35°C) 5,03 4,84 5,03 4,84
Indoor net weight kg 40 (3kW) / 41 (6kW) 41 40 (3kW) / 41 (9kW) 41
Indoor dimension (Height) mm 892 892 892 892
Pipe length range m 3 ~ 30 3 ~ 30 3 ~ 30 3 ~ 30
EER (A 35°C, W 7°C) 3,11 2,68 3,11 2,68
Cooling capacity (A 35°C, W 7°C) kW 8,80 10,70 8,80 10,70
COP (A -7°C, W 35°C) 3,00 2,72 3,00 2,72
Heating capacity (A -7°C, W 35°C) kW 9,00 12,00 9,00 12,00
COP (A +2°C, W 35°C) 3,69 3,44 3,69 3,44
Heating capacity (A +2°C, W 35°C) kW 9,00 12,00 9,00 12,00
Outdoor dimension (Height) mm 1.340 1.340 1.340 1.340
Heating capacity (A +7°C, W 35°C) kW 9,00 12,10 9,00 12,10
Additional gas amount g/m 30 30 30 30
Heating capacity (A -7°C, W 55°C) kW 9,00 12,00 9,00 12,00
COP (A +2°C, W 55°C) 2,31 2,29 2,31 2,29
Heating capacity (A +2°C, W 55°C) kW 9,00 12,00 9,00 12,00
COP (A +7°C, W 55°C) 3,07 3,04 3,07 3,04
Heating capacity (A +7°C, W 55°C) kW 9,00 12,10 9,00 12,10
Outdoor unit WH-UXZ09KE5 WH-UXZ12KE5 WH-UXZ09KE8 WH-UXZ12KE8
Pipe length for additional gas m 10 10 10 10
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) 1/2 (12,70) 1/2 (12,70)
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Indoor dimension (Depth) mm 348 348 348 348
Indoor dimension (Width) mm 500 500 500 500
Refrigerant (R32) / CO2 Eq. kg / T 1,60 / 1,080 1,60 / 1,080 1,60 / 1,080 1,60 / 1,080
Indoor sound pressure (Heat) dB(A) 33 33 33 33
Outdoor net weight kg 88 88 90 90
(1) Scale from A+++ to D.
(2) Sound power in accordance to 811/2013, 813/2013 and EN12102-1:2017 at +7°C.
(3) Check local regulations.
* EER and COP calculation is based in accordance to EN14511.
** This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.
*** Tentative data.