Řada iCOOL OCU – MT

Předchozí výkon Další výkon

4.7kW

OCU-KRC045M08

Řada iCOOL OCU pro aplikace MT

Možnost oslovit větší publikum a pokrýt trh kondenzačních jednotek (CDU), na který se CO2 dosud nevztahuje.

Technické údaje

Zobrazit vše
Řada iCOOL OCU – MT
4.7 kW
Model OCU-KRC045M08
Compressors Jeden kompresor
Compatible refrigerants R448A, R449A, R134a, R513A
PED CAT I
Application and nominal cooling capacity MT/LT (kW) MT
MT (R449A/R448A) - Cooling capacity at .
ET -15°C, AT 32°C (Min - Max) kW 0,6–3,9
ET -15°C, AT 38°C (Min - Max) kW 0,6–3,8
ET -15°C, AT 43°C (Min - Max) kW 0,6–3,8
ET -10°C, AT 32°C (Min - Max) kW 0,8–4,7
ET -10°C, AT 38°C (Min - Max) kW 0,8–4,6
ET -10°C, AT 43°C (Min - Max) kW 0,7 - 4,6
ET -5°C, AT 32°C (Min - Max) kW 0,9–5,7
ET -5°C, AT 38°C (Min - Max) kW 0,9–5,6
ET -5°C, AT 43°C (Min - Max) kW 0,9–5,6
MT (R134a/R513A) - Cooling capacity at .
ET -15°C; AT 32°C (Min - Max) kW — - —
ET -15°C; AT 38°C (Min - Max) kW — - —
ET -15°C; AT 43°C (Min - Max) kW — - —
ET -10°C; AT 32°C (Min - Max) kW 0,5–3,4
ET -10°C; AT 38°C (Min - Max) kW 0,5 - 3,2
ET -10°C; AT 43°C (Min - Max) kW 0,4 - 2,9
ET -5°C; AT 32°C (Min - Max) kW 0,6–4,0
ET -5°C; AT 38°C (Min - Max) kW 0,5–3,7
ET -5°C; AT 43°C (Min - Max) kW 0,5–3,4
SEPR cooling at ET -10°C AT 32°C 3,28
Annual electricity consumption at ET -10°C AT 32°C kWh/a 9.070
Nominal operating current at ET -10°C MT / -30°C LT AT 32°C and 230 - 400V 50Hz A 5,0
Maximum operating current (in the most loaded phase at 230 - 400V 50Hz) A 7,2
Maximum power consumption kW 3,7
Dimension (Width) mm 1.106
Dimension (Height) mm 559
Dimension (Depth) mm 461
Net weight kg 94
Sound level at 10m dB(A) 39,0
Oil charge dm³ 0,7 + 0,4
Connections (Suction) Inch (mm) 5/8
Connections (Liquid) Inch (mm) 3/8
Liquid receiver dm³ 3,9
Length of connection piping m 40
Maximum height distance (Evaporator above) m 12
Maximum height distance (Evaporator below) m 12
Which pipes needs to be insulated (Suction / liquid / both) Sání
Recommended insulation thickness mm 13
Maximum quantity of evaporators connected Qty. 5
Evaporation temperature (Min) °C -15
Evaporation temperature (Max) °C 5
Ambient temperature (Min) °C -20
Ambient temperature (Max) °C 43
Condenser
Fans x diameter mm 1 x 450
Air flow (Nominal) m³/h 3.850
Fan static pressure Pa Nevztahuje se
Fan power supply V / ph / Hz 200 - 277 / 1 / 50
Fan power consumption W 170
Nominal fan amperage A 1,4
Compressor - additional data
Compressor model C-7RVN113L0A
Volumetric flow m³/h 1,25–7,5
Rotation range rps 15–90
Current (Full load amperage) A 5,8
Current (Peak current limit / Locked rotor amperage) A 17,8 / —
Oil type FV68S (PVE)
Crankcase heater power consumption W 35
CU power supply
Voltage V / ph / Hz 3 x 400 / 50 PE+N (TN-S)
Recommended minimum cable cross-section mm² 5x2,5
Recommended minimum protection C16