6.6kW

OCU-KRE070M05

Řada iCOOL SE. Aplikace Jednoduché technické řešení pro MT

Od 2,5 do 10,0 kW.

Instalace zjednodušeného procesu uvedení do provozu. Technologie, která se chová takhle.

Ušetřete čas a provozní náklady s našimi energeticky úspornými jednotkami založenými na invertorových kompresorech.

Technické údaje

Zobrazit vše
Řada iCOOL SE - MT
6.6 kW
Model OCU-KRE070M05
Compressors Jeden kompresor
Compatible refrigerants R448A, R449A, R134a, R513A
PED CAT I
Application and nominal cooling capacity MT/LT (kW) MT
MT (R449A*/R448A*) - Cooling capacity at .
ET -15°C, AT 32°C (Min - Max) kW 1,9–5,5
ET -15°C, AT 38°C (Min - Max) kW 1,8–5,0
ET -15°C, AT 43°C (Min - Max) kW 1,7–4,6
ET -10°C, AT 32°C (Min - Max) kW 2,3–6,6
ET -10°C, AT 38°C (Min - Max) kW 2,2 - 6,0
ET -10°C, AT 43°C (Min - Max) kW 2,0–5,3
ET -5°C, AT 32°C (Min - Max) kW 2,8–7,6
ET -5°C, AT 38°C (Min - Max) kW 2,6–6,8
ET -5°C, AT 43°C (Min - Max) kW 2,4–5,9
MT (R134a*/R513A*) - Cooling capacity at .
ET -15°C; AT 32°C (Min - Max) kW 0,9–3,1
ET -15°C; AT 38°C (Min - Max) kW 0,9–2,8
ET -15°C; AT 43°C (Min - Max) kW 0,8–2,6
ET -10°C; AT 32°C (Min - Max) kW 1,2–3,9
ET -10°C; AT 38°C (Min - Max) kW 1,1 - 3,5
ET -10°C; AT 43°C (Min - Max) kW 1,0 - 3,3
ET -5°C; AT 32°C (Min - Max) kW 1,5–4,8
ET -5°C; AT 38°C (Min - Max) kW 1,4–4,4
ET -5°C; AT 43°C (Min - Max) kW 1,3–4,0
MT (R455A/R454C*) - Cooling capacity at .
ET -15°C | AT 32°C (Min - Max) kW
ET -15°C | AT 38°C (Min - Max) kW
ET -15°C | AT 43°C (Min - Max) kW
ET -10°C | AT 32°C (Min - Max) kW
ET -10°C | AT 38°C (Min - Max) kW
ET -10°C | AT 43°C (Min - Max) kW
ET -5°C | AT 32°C (Min - Max) kW
ET -5°C | AT 38°C (Min - Max) kW
ET -5°C | AT 43°C (Min - Max) kW
SEPR cooling at ET -10°C AT 32°C (R448A-OCU-K, R455A-OCU-L) 3,80
Annual electricity consumption at ET -10°C AT 32°C (R448A-OCU-K, R455A-OCU-L) kWh/a 10 749
COP at ET -10°C, AT 32°C (R448A)
Nominal operating current at ET -10°C MT / -30°C LT AT 32°C and 230 - 400V 50Hz A 14,7
Maximum operating current (in the most loaded phase at 230 - 400V 50Hz) A 17,4
Maximum power consumption kW 3,6
Dimension (Width) mm 1 100
Dimension (Height) mm 805
Dimension (Depth) mm 450
Net weight kg 80
Sound level at 10m dB(A) 42,5
Connections (Suction) Inch (mm) 3/4
Connections (Liquid) Inch (mm) 3/8
Liquid receiver dm³ 5,3
Length of connection piping m 30
Maximum height distance (Evaporator above) m 7
Maximum height distance (Evaporator below) m 7
Which pipes needs to be insulated (Suction / liquid / both) Sání
Recommended insulation thickness mm 13
Maximum quantity of evaporators connected Qty. 3
Evaporation temperature (Min) °C -15
Evaporation temperature (Max) °C 0
Ambient temperature (Min) °C -20
Ambient temperature (Max) °C 43
Condenser .
Fans x diameter mm 1x500
Air flow (Nominal) m³/h 5.200
Fan power supply V / ph / Hz 220 - 240 / 1 / 50
Fan power consumption W 230
Nominal fan amperage A 2,1
Compressor - additional data .
Compressor model C-7RVN153L0B
Volumetric flow m³/h 1,7–10,4
Rotation range rps 30–90
Current (Full load amperage) A 9,4
Current (Peak current limit / Locked rotor amperage) A 25 / —
Oil type FV68S
Oil compressor charge dm³ 0,7
Crankcase heater power consumption W 35
CU power supply .
Voltage V / ph / Hz 220 - 240 / 1 / 50
Recommended minimum cable cross-section mm² 3x2,5
Recommended minimum protection C20