Bi-bloc M Series 1 phase – 3 phase · R290

16.00kW

WH-WDG16ME8 + WH-SDC0316M9E8

Aquarea High Performance M Series, the next generation of heat pumps with R290 

Combining flexible system design, quiet operation and up to 75°C water flow, the Aquarea High Performance M Series offers a reliable, high‑quality heat pump solution for new‑build and retrofit applications.
  • R290 refrigerant with GWP of just 0,02
  • A+++ in heating at 35°C 
  • Up to 75°C water outlet temperature, even at outdoor temperatures down to -15°C
  • Reliable operation with Panasonic compressor, down to -25°C outdoor temperature
  • Comfort Cloud App and Aquarea Service Cloud included as standard
  • Flexible installation with customizable tank size
  • Hydronic indoor-outdoor connection for easier system integration
  • Specifications

    See all
    Bi-bloc M Series 1 phase – 3 phase · R290
    16.00 kW
    Outdoor unit WH-WDG16ME8
    Heating capacity (A +7°C, W 35°C) kW 16,00
    COP (A +7°C, W 35°C) 4,65
    Heating capacity (A +7°C, W 55°C) kW 14,70
    COP (A +7°C, W 55°C) 3,00
    Heating capacity (A +2°C, W 35°C) kW 13,00
    COP (A +2°C, W 35°C) 3,30
    Heating capacity (A +2°C, W 55°C) kW 12,00
    COP (A +2°C, W 55°C) 2,27
    Heating capacity (A -7°C, W 35°C) kW 11,70
    COP (A -7°C, W 35°C) 2,63
    Heating capacity (A -7°C, W 55°C) kW 10,80
    COP (A -7°C, W 55°C) 1,90
    Cooling capacity (A 35°C, W 7°C) kW 9,00
    EER (A 35°C, W 7°C) 3,61
    Cooling capacity (A 35°C, W 18°C) kW 9,00
    EER (A 35°C, W 18°C) 5,26
    Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,58 / 3,58
    Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 180 / 140
    Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++
    Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,20 / 4,34
    Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 245 / 171
    Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++
    Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,30 / 3,26
    Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 169 / 127
    Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A++
    Outdoor sound power (Heat) (2) dB(A) 58
    Outdoor dimension (Height) mm 1.520
    Outdoor dimension (Width) mm 1.200
    Outdoor dimension (Depth) mm 370
    Outdoor net weight kg 151
    A class pump (Number of speeds) Variable speed
    A class pump (Input power Min) W 30
    A class pump (Input power Max) W 175
    Heating water flow (∆T=5 K. 35°C) L/min 45,9
    Refrigerant (R290) / CO2 Eq. (3) kg / T 1,58 / 0,00003
    Operation range - Outdoor ambient (Heat) °C -25 ~ +35
    Operation range - Outdoor ambient (Cool) °C +10 ~ +43
    Water outlet (Cool) °C 5 ~ 20
    Indoor unit 3kW electric heater
    Indoor unit 6kW electric heater
    Indoor unit 9kW electric heater WH-SDC0316M9E8
    Indoor dimension (Height) mm 892
    Indoor dimension (Width) mm 500
    Indoor dimension (Depth) mm 348
    Indoor net weight kg 29
    Water pipe connector (room) Inch
    Water pipe connector (indoor units) Inch
    Water pipe connector (outdoor units) Inch
    Pipe length range standard m 5
    Pipe length range maximum m 30
    Elevation difference (in/out) m 30

    (1) Scale from A+++ to D.
    (2) Sound power level in accordance with EN 12102 under conditions of the EN 14825 (part load).
    (3) WH-WDG models are hermetically sealed.
    (4) Water outlet up to 75°C above -15°C outdoor. Between outdoor ambient -15°C and -25°C, the water outlet temperature gradually decreases from 75°C to 55°C.
    (5) Check local regulations.
    *EER and COP calculation is based in accordance with EN 14511.
    **This product is designed to comply with the European drinking water standard (EU) 2020/2184. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.