Specifications
| Floor Console Inverter+ • R32 | SINGLE PHASE | ||||
|---|---|---|---|---|---|
| 2.5 kW | 3.5 kW | 5.0 kW | |||
| Cooling capacity (Min) | kW | 0,85 | 0,85 | 0,90 | |
| Input power heating (Min) | kW | 0,24 | 0,24 | 0,26 | |
| COP (Max) (1) | W/W | 3,70 | 3,43 | 3,12 | |
| COP (Min) (1) | W/W | 3,54 | 3,54 | 3,46 | |
| Heating capacity (Max) | kW | 5,00 | 6,00 | 8,10 | |
| Heating capacity (Min) | kW | 0,85 | 0,85 | 0,90 | |
| Input power cooling (Max) | kW | 0,90 | 1,02 | 1,81 | |
| Input power cooling (Min) | kW | 0,24 | 0,24 | 0,26 | |
| EER (Max) (1) | W/W | 3,78 | 3,73 | 3,15 | |
| EER (Min) (1) | W/W | 3,54 | 3,54 | 3,53 | |
| Cooling capacity (Max) | kW | 3,40 | 3,80 | 5,70 | |
| Input power heating (Max) | kW | 1,35 | 1,75 | 2,60 | |
| Operating range (Heat - Max) | °C | +24 | +24 | +24 | |
| Operating range (Heat - Min) | °C | -15 | -15 | -15 | |
| Operating range (Cool - Max) | °C | +43 | +43 | +43 | |
| Elevation difference (in/out) (6) | m | 15 | 15 | 20 | |
| Outdoor dimension (Depth) (5) | mm | 289 | 299 | 320 | |
| Outdoor dimension (Width) (5) | mm | 780 | 824 | 875 | |
| Outdoor dimension (Height) (5) | mm | 542 | 619 | 695 | |
| Outdoor sound pressure (Heat -Hi) (4) | dB(A) | 47 | 48 | 48 | |
| Outdoor unit | CU-Z25CBEA | CU-Z35CBEA | CU-Z50CBEA | ||
| nanoe X Generator | Mark 3 | Mark 3 | Mark 3 | ||
| Outdoor connection indoor / outdoor | mm² | 4x1,5 | 4x1,5 | 4x1,5 | |
| Outdoor recommended fuse | A | 16 | 16 | 16 | |
| Outdoor air flow (Heat) | m³/min | 27,2 | 31,8 | 36,4 | |
| Outdoor air flow (Cool) | m³/min | 28,7 | 34,3 | 39,7 | |
| Indoor unit | CS-Z25CFEAW | CS-Z35CFEAW | CS-Z50CFEAW | ||
| Indoor sound pressure (Heat -Q-Lo) (4) | dB(A) | 19 | 19 | 29 | |
| Indoor sound pressure (Heat -Lo) (4) | dB(A) | 25 | 26 | 33 | |
| Indoor sound pressure (Heat -Hi) (4) | dB(A) | 38 | 39 | 46 | |
| Indoor sound pressure (Cool -Q-Lo) (4) | dB(A) | 20 | 20 | 27 | |
| Indoor sound pressure (Cool -Lo) (4) | dB(A) | 25 | 26 | 31 | |
| Moisture removal volume | L/h | 1,5 | 2,0 | 2,8 | |
| Indoor air flow (Heat) | m³/min | 10,0 | 10,1 | 13,4 | |
| Indoor air flow (Cool) | m³/min | 9,6 | 9,7 | 11,9 | |
| Annual energy consumption heating (3) | kWh/a | 822 | 974 | 1.433 | |
| Annual energy consumption cooling (3) | kWh/a | 111 | 151 | 261 | |
| Input power cooling (Nominal) | kW | 0,52 | 0,86 | 1,39 | |
| Pdesign (cooling) | kW | 2,50 | 3,50 | 5,00 | |
| SEER (2) | 7,90 A++ | 8,10 A++ | 6,70 A++ | ||
| Outdoor net weight | kg | 32 | 33 | 43 | |
| Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 46 | 48 | 48 | |
| Indoor net weight | kg | 13 | 13 | 13 | |
| Indoor dimension (Height) | mm | 600 | 600 | 600 | |
| Indoor sound pressure (Cool -Hi) (4) | dB(A) | 38 | 39 | 44 | |
| SCOP (2) | 4,60 A++ | 4,60 A++ | 4,30 A+ | ||
| Pipe length range | m | 3 ~ 20 | 3 ~ 20 | 3 ~ 30 | |
| Heating capacity at -7°C | kW | 2,88 | 3,37 | 5,03 | |
| Kit | KIT-Z25-CFE | KIT-Z35-CFE | KIT-Z50-CFE | ||
| Additional gas amount | g/m | 10 | 10 | 15 | |
| Pipe length for additional gas | m | 7,5 | 7,5 | 7,5 | |
| Pipe diameter (Gas) | Inch (mm) | 3/8 (9,52) | 3/8 (9,52) | 1/2 (12,70) | |
| Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | |
| Indoor dimension (Depth) | mm | 207 | 207 | 207 | |
| Indoor dimension (Width) | mm | 750 | 750 | 750 | |
| Refrigerant (R32) / CO2 Eq. | kg / T | 0,88 / 0,59 | 0,97 / 0,65 | 1,13 / 0,76 | |
| EER (Nominal) (1) | W/W | 4,81 | 4,07 | 3,60 | |
| COP (Nominal) (1) | W/W | 4,47 | 3,98 | 3,74 | |
| Outdoor power source | V | 230 | 230 | 230 | |
| Heating capacity (Nominal) | kW | 3,40 | 4,30 | 5,80 | |
| Cooling capacity (Nominal) | kW | 2,50 | 3,50 | 5,00 | |
| Operating range (Cool - Min) | °C | -10 | -10 | -10 | |
| Input power heating (Nominal) | kW | 0,76 | 1,08 | 1,55 | |
| Pdesign at -10°C | kW | 2,70 | 3,20 | 4,40 | |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the units shows the value measured of a position 1 m in front of the main body and 1 m above floor. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
(5) Add 70 mm for piping port.
(6) When installing the outdoor unit at a higher position than the indoor unit.