PACi Elite Ceiling • R410A

This range of ceiling mounted units feature a DC fan motor for increased efficiency and reduced operating sound levels.

All the units are the same height and depth for a uniform appearance in mixed installations. A knock out is provided to allow for supplementary fresh air for improved air quality.

  • Wide air distribution for large rooms
  • Horizontal air flow reaches maximum 9,5 m
  • Fresh air connection available on the unit
  • Slim design with 235 m height fits narrow space
  • Silent operation
  • Datanavi simple support tool App with remote controller (CZ-RTC5B)
  • Twin, Triple and Double-twin split options
  • Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB. The external device can be controlled by the remote control of the Panasonic indoor unit

Specifications

See all
PACi Elite Ceiling • R410A SINGLE PHASE THREE PHASE
36 kW 50 kW 60 kW 71 kW 100 kW 125 kW 140 kW 71 kW 100 kW 125 kW 140 kW
EER (Nominal) (1) W/W 4,80 (6,25 - 4,49) A 3,73 (6,25 - 3,41) A 3,73 (8,00 - 3,16) A 3,68 (5,56 - 2,88) A 3,95 (3,93 - 3,25) A 3,35 (3,93 - 2,88) A 3,01 (3,93 - 2,65) B 3,68 (5,56 - 2,88) A 3,95 (3,93 - 3,25) A 3,35 (3,93 - 2,88) A 3,01 (3,93 - 2,65) B
COP (Nominal) (1) W/W 5,00 (7,89 - 4,50) A 4,18 (7,89 - 3,78) A 4,22 (9,00 - 4,10) A 4,15 (5,00 - 3,10) A 4,31 (4,56 - 3,18) A 3,99 (4,56 - 3,07) A 3,67 (4,56 - 3,04) A 4,15 (5,00 - 3,10) A 4,31 (4,56 - 3,18) A 3,99 (4,56 - 3,07) A 3,67 (4,56 - 3,04) A
Kit KIT-36PT2E5D KIT-50PT2E5D KIT-60PT2E5D KIT-71PT2E5D KIT-100PT2E5D KIT-125PT2E5D KIT-140PT2E5D KIT-71PT2E8D KIT-100PT2E8D KIT-125PT2E8D KIT-140PT2E8D
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
Cooling capacity (Nominal) kW 3,60 5,00 6,00 7,10 10,00 12,50 14,00 7,10 10,00 12,50 14,00
Cooling capacity (Min) kW 1,50 1,50 2,00 2,50 3,30 3,30 3,30 2,50 3,30 3,30 3,30
Cooling capacity (Max) kW 4,00 5,60 7,10 8,00 12,50 14,00 15,00 8,00 12,50 14,00 15,00
EER (Nominal) (1) W/W 4,80 3,73 3,73 3,68 3,95 3,35 3,01 3,68 3,95 3,35 3,01
EER (Min) (1) W/W 6,25 6,25 8,00 5,56 3,93 3,93 3,93 5,56 3,93 3,93 3,93
EER (Max) (1) W/W 4,49 3,41 3,16 2,88 3,25 2,88 2,65 2,88 3,25 2,88 2,65
SEER (2) 6,70 A++ 6,50 A++ 6,80 A++ 6,20 A++ 6,70 A++ 5,76 5,36 5,90 A+ 6,60 A++ 5,74 5,34
Pdesign (cooling) kW 3,60 5,00 6,00 7,10 10,00 12,50 14,00 7,10 10,00 12,50 14,00
Input power cooling (Nominal) kW 0,75 1,34 1,61 1,93 2,53 3,73 4,65 1,93 2,53 3,73 4,65
Input power cooling (Min) kW 0,24 0,24 0,25 0,45 0,84 0,84 0,84 0,45 0,84 0,84 0,84
Input power cooling (Max) kW 0,89 1,64 2,25 2,78 3,85 4,86 5,65 2,78 3,85 4,86 5,65
Annual energy consumption cooling (3) kWh/a 188 269 309 965 523 421 531
Heating capacity (Nominal) kW 4,00 5,60 7,00 8,00 11,20 14,00 16,00 8,00 11,20 14,00 16,00
Heating capacity (Min) kW 1,50 1,50 1,80 2,00 4,10 4,10 4,10 2,00 4,10 4,10 4,10
Heating capacity (Max) kW 5,00 6,50 8,00 9,00 14,00 16,00 18,00 9,00 14,00 16,00 18,00
Heating capacity at -7°C (4) kW 7,52 12,04 13,48 14,24 7,52 12,04 13,48 14,24
Heating capacity at -15°C (4) kW 7,65 11,20 12,38 12,69 7,65 11,20 12,38 12,69
COP (Nominal) (1) W/W 5,00 4,18 4,22 4,15 4,31 3,99 3,67 4,15 4,31 3,99 3,67
COP (Min) (1) W/W 7,89 7,89 9,00 5,00 4,56 4,56 4,56 5,00 4,56 4,56 4,56
COP (Max) (1) W/W 4,50 3,78 4,10 3,10 3,18 3,07 3,04 3,10 3,18 3,07 3,04
SCOP (2) 4,30 A+ 4,10 A+ 4,10 A+ 4,00 A+ 4,30 A+ 3,81 3,70 4,00 A+ 4,30 A+ 3,81 3,70
Pdesign at -10°C kW 3,60 5,00 6,00 7,10 10,00 12,50 14,00 7,10 10,00 12,50 14,00
Input power heating (Nominal) kW 0,80 1,34 1,66 1,93 2,60 3,51 4,36 1,93 2,60 3,51 4,36
Input power heating (Min) kW 0,19 0,19 0,20 0,40 0,90 0,90 0,90 0,40 0,90 0,90 0,90
Input power heating (Max) kW 1,11 1,72 1,95 2,90 4,40 5,21 5,93 2,90 4,40 5,21 5,93
Annual energy consumption heating (3) kWh/a 1172 1707 2050 2485 3256 2485 3256
Indoor unit S-36PT2E5B S-50PT2E5B S-60PT2E5B S-71PT2E5B S-100PT2E5B S-125PT2E5B S-140PT2E5B S-71PT2E5B S-100PT2E5B S-125PT2E5B S-140PT2E5B
Indoor air flow (Hi) m³/min 14,00 15,00 20,00 21,00 30,00 34,00 35,00 21,00 30,00 34,00 35,00
Indoor air flow (Med) m³/min 12,00 12,50 17,00 18,00 25,00 28,00 29,00 18,00 25,00 28,00 29,00
Indoor air flow (Lo) m³/min 10,50 10,50 14,50 15,50 23,00 24,00 25,00 15,50 23,00 24,00 25,00
Indoor sound pressure (Hi) (5) dB(A) 36 37 38 39 42 46 47 39 42 46 47
Indoor sound pressure (Med) (5) dB(A) 32 33 34 35 37 40 41 35 37 40 41
Indoor sound pressure (Lo) (5) dB(A) 29 29 30 31 35 36 37 31 35 36 37
Indoor dimension (Height) mm 235 235 235 235 235 235 235 235 235 235 235
Indoor dimension (Width) mm 960 960 1275 1275 1590 1590 1590 1275 1590 1590 1590
Indoor dimension (Depth) mm 690 690 690 690 690 690 690 690 690 690 690
Indoor net weight kg 27 27 33 33 40 40 40 33 40 40 40
Outdoor unit U-36PE2E5A U-50PE2E5A U-60PE2E5A U-71PE1E5A U-100PE1E5A U-125PE1E5A U-140PE1E5A U-71PE1E8A U-100PE1E8A U-125PE1E8A U-140PE1E8A
Outdoor power source V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415
Outdoor recommended fuse A 20 25 30 16 16 16 16 16
Outdoor connection indoor / outdoor mm² 2,5 4,0 6,0 2,5 2,5 2,5 2,5 2,5
Current in cooling (1p 220V / 3p 380) A 3,55 6,30 7,90 9,00 11,50 17,00 21,20 3,00 3,95 5,85 7,30
Current in cooling (1p 230V / 3p 400) A 3,40 6,00 7,50 8,70 11,10 16,40 20,50 2,90 3,75 5,55 6,95
Current in cooling (1p 240V / 3p 415) A 3,25 5,75 7,20 8,40 10,60 15,80 19,80 2,80 3,65 5,35 6,70
Current in heating (1p 220V / 3p 380) A 3,80 6,35 8,15 8,90 11,80 16,00 19,80 3,00 4,05 5,50 6,85
Current in heating (1p 230V / 3p 400) A 3,65 6,10 7,80 8,60 11,40 15,40 19,20 2,90 3,85 5,20 6,50
Current in heating (1p 240V / 3p 415) A 3,50 5,80 7,45 8,30 11,00 14,90 18,50 2,80 3,75 5,05 6,25
Outdoor air flow (Cool) m³/min 38 38 38 60 110 130 135 60 110 130 135
Outdoor air flow (Heat) m³/min 38 41 41 60 95 110 120 60 95 110 120
Outdoor sound pressure (Cool -Hi) dB(A) 45 46 46 48 52 53 54 48 52 53 54
Outdoor sound pressure (Heat -Hi) dB(A) 46 48 49 50 52 53 55 50 52 53 55
Outdoor dimension (Height) mm 619 619 619 996 1416 1416 1416 996 1416 1416 1416
Outdoor dimension (Width) mm 799 799 799 940 940 940 940 940 940 940 940
Outdoor dimension (Depth) mm 299 299 299 340 340 340 340 340 340 340 340
Outdoor net weight kg 39 39 40 69 98 98 98 71 98 98 98
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 3 ~ 40 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 75 5 ~ 75 5 ~ 75 5 ~ 50 5 ~ 75 5 ~ 75 5 ~ 75
Elevation difference (in/out) (5) m 30 30 30 30 30 30 30 30 30 30 30
Pipe length for additional gas m 30 30 30 30 30 30 30 30 30 30 30
Additional gas amount g/m 20 20 40 50 50 50 50 50 50 50 50
Refrigerant (R410A) / CO2 Eq. kg / T 1,40 / 2,9232 1,40 / 2,9232 1,95 / 4,0716 2,35 / 4,9068 3,40 / 7,0992 3,40 / 7,0992 3,40 / 7,0992 2,35 / 4,9068 3,40 / 7,0992 3,40 / 7,0992 3,40 / 7,0992
Operating range (Cool - Min) °C -15 -15 -15 -15 -15 -15 -15 -15 -15 -15 -15
Operating range (Cool - Max) °C +46 +46 +46 +46 +46 +46 +46 +46 +46 +46 +46
Operating range (Heat - Min) °C -20 -20 -20 -20 -20 -20 -20 -20 -20 -20 -20
Operating range (Heat - Max) °C +24 +24 +24 +24 +24 +24 +24 +24 +24 +24 +24

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.0
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) Heating capacity is calculated including defrost factor correction.
(5) The sound pressure of the units shows the value measured of the position 1 m in front of the main body and 1 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(6) When installing the outdoor unit at a higher position than the indoor unit. * Recommended fuse for the indoor 3 A.