PACi Elite Wall-Mounted • R32

The range units allows for many more applications such as studios, gyms, high ceiling areas and even computer server rooms.

The unit’s compact design and flat face ensure discreet installation, even in a small space.

  • Modern design with flat face and compact size
  • Stylish matt white color
  • DC FAN for better efficiency and control
  • Six directional piping outlet
  • Datanavi simple support tool App with remote controller (CZ-RTC5B)
  • Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB. The external device can be controlled by the remote control of the Panasonic indoor unit

Specifications

See all
PACi Elite Wall-Mounted • R32 SINGLE PHASE THREE PHASE
36 kW 50 kW 61 kW 71 kW 71 kW 95 kW 95 kW
Kit KIT-36PK2ZH5 KIT-50PK2ZH5 KIT-60PK2ZH5 KIT-71PK2ZH5 KIT-71PK2ZH8 KIT-100PK2ZH5 KIT-100PK2ZH8
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
Cooling capacity (Nominal) kW 3,6 5,0 6,1 7,1 7,1 9,5 9,5
Cooling capacity (Min) kW 1,5 1,5 2,0 2,2 2,2 3,1 3,1
Cooling capacity (Max) kW 4,0 5,6 7,1 9,0 9,0 10,5 10,5
EER (Nominal) (1) W/W 4,90 4,10 3,86 3,50 3,50 3,26 3,26
SEER (2) 8,0 A++ 7,6 A++ 7,2 A++ 6,8 A++ 6,7 A++ 6,4 A++ 6,3 A++
Pdesign (cooling) kW 3,6 5,0 6,1 7,1 7,1 9,5 9,5
Input power cooling (Nominal) kW 0,74 1,22 1,58 2,03 2,03 2,91 2,91
Annual energy consumption cooling (3) kWh/a 157 230 297 365 370 520 526
Heating capacity (Nominal) kW 4,0 5,6 7,0 8,0 8,0 9,5 9,5
Heating capacity (Min) kW 1,5 1,5 1,8 2,0 2,0 3,1 3,1
Heating capacity (Max) kW 5,0 6,5 8,0 9,0 9,0 11,5 11,5
COP (Nominal) (1) W/W 4,94 4,21 4,46 4,00 4,00 3,97 3,97
SCOP (2) 4,9 A++ 4,7 A++ 4,8 A++ 4,7 A++ 4,7 A++ 4,1 A+ 4,1 A+
Pdesign at -10°C kW 3,6 4,5 6,0 5,2 5,2 8,0 8,0
Input power heating (Nominal) kW 0,81 1,33 1,57 2,00 2,00 2,39 2,39
Annual energy consumption heating (3) kWh/a 1029 1340 1750 1549 1549 2732 2732
Indoor unit S-36PK2E5B S-50PK2E5B S-60PK2E5B S-71PK2E5B S-71PK2E5B S-100PK2E5B S-100PK2E5B
Indoor air flow (Hi) m³/min 13,0 16,0 20,0 20,0 20,0 22,0 22,0
Indoor air flow (Med) m³/min 11,0 14,0 18,0 17,5 17,5 18,5 18,5
Indoor air flow (Lo) m³/min 9,0 11,0 15,0 14,5 14,5 15,0 15,0
Indoor sound pressure (Med) (4) dB(A) 31 36 44 44 44 45 45
Indoor sound pressure (Lo) (4) dB(A) 27 32 40 40 40 41 41
Indoor dimension (Height) mm 302 302 302 302 302 302 302
Indoor dimension (Width) mm 1120 1120 1120 1120 1120 1120 1120
Indoor dimension (Depth) mm 236 236 236 236 236 236 236
Indoor net weight kg 13 13 14 14 14 14 14
Outdoor unit U-36PZH2E5 U-50PZH2E5 U-60PZH2E5 U-71PZH2E5 U-71PZH2E8 U-100PZH2E5 U-100PZH2E8
Outdoor power source V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415 220 - 230 - 240 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 3,55 5,70 7,70 9,55 3,20 13,50 4,60
Current in cooling (1p 230V / 3p 400) A 3,40 5,50 7,35 9,10 3,05 12,90 4,35
Current in cooling (1p 240V / 3p 415) A 3,25 5,25 7,05 8,75 2,95 12,40 4,20
Current in heating (1p 220V / 3p 380) A 3,95 6,35 7,65 9,20 3,10 11,10 3,75
Current in heating (1p 230V / 3p 400) A 3,75 6,05 7,30 8,80 3,00 10,60 3,55
Current in heating (1p 240V / 3p 415) A 3,60 5,80 7,00 8,50 2,85 10,10 3,45
Outdoor air flow (Cool) m³/min 40 40 40 61 61 118 118
Outdoor air flow (Heat) m³/min 40 45 45 60 60 108 108
Outdoor sound pressure (Cool -Hi) dB(A) 43 45 46 48 48 52 52
Outdoor sound pressure (Heat -Hi) dB(A) 44 48 49 50 50 52 52
Outdoor sound power (Cool -Hi) dB(A) 62 64 65 65 65 69 69
Outdoor sound power (Heat -Hi) dB(A) 64 68 69 67 67 69 69
Outdoor dimension (Height) mm 695 695 695 996 996 1416 1416
Outdoor dimension (Width) mm 875 875 875 940 940 940 940
Outdoor dimension (Depth) mm 320 320 320 340 340 340 340
Outdoor net weight kg 43 43 44 68 68 99 99
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 3 ~ 40 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 50 5 ~ 85 5 ~ 85
Elevation difference (in/out) (5) m 30 30 30 30 30 30 30
Pipe length for additional gas m 30 30 30 30 30 30 30
Additional gas amount g/m 20 20 35 45 45 45 45
Refrigerant (R32) / CO2 Eq. kg / T 1,15 / 0,776 1,15 / 0,776 1,45 / 0,979 1,95 / 1,316 1,95 / 1,316 3,05 / 2,059 3,05 / 2,059
Operating range (Cool - Min) °C -15 -15 -15 -15 -15 -20 (6) -20 (6)
Operating range (Cool - Max) °C 46 46 46 46 46 46 46
Operating range (Heat - Min) °C -20 -20 -20 -20 -20 -20 -20
Operating range (Heat - Max) °C 24 24 24 24 24 24 24

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the units shows the value measured of the position 1 m in front of the main body and 1 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(5) When installing the outdoor unit at a higher position than the indoor unit.
(6) For models 100 ~ 140PZH2E5(8), it is possible to operate the lowest -20 °C in the computer rooms with the piping length of 30 m or less.
* Recommended fuse for the indoor 3 A.