PACi Standard Ceiling • R410A

This range of ceiling mounted units feature a DC fan motor for increased efficiency and reduced operating sound levels.

All the units are the same height and depth for a uniform appearance in mixed installations. A knock out is provided to allow for supplementary fresh air for improved air quality.

  • Wide air distribution for large rooms
  • Horizontal air flow reaches maximum 9,5 m
  • Fresh air connection available on the unit
  • Slim design with 235 m height fits narrow space
  • Silent operation
  • Datanavi simple support tool App with remote controller (CZ-RTC5B)
  • Twin, Triple and Double-twin split options
  • Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB. The external device can be controlled by the remote control of the Panasonic indoor unit

Specifications

See all
PACi Standard Ceiling • R410A SINGLE PHASE THREE PHASE
60 kW 71 kW 100 kW 125 kW 100 kW 125 kW 140 kW
EER (Nominal) (1) W/W 3,68 (8,00 - 3,16) A 3,21 (8,00 - 2,91) A 3,01 (5,09 - 2,65) B 3,01 (4,22 - 2,62) B 3,01 (5,09 - 2,65) B 3,01 (4,22 - 2,62) B 2,98 (3,93 - 2,63) C
COP (Nominal) (1) W/W 4,35 (9,00 - 4,38) A 4,23 (9,00 - 3,77) A 3,85 (5,12 - 3,45) A 3,85 (4,66 - 3,41) A 3,85 (5,12 - 3,45) A 3,85 (4,66 - 3,41) A 3,88 (4,56 - 3,07) A
Kit KIT-60PTY2E5D KIT-71PTY2E5D KIT-100PTY2E5D KIT-125PTY2E5D KIT-100PTY2E8D KIT-125PTY2E8D KIT-140PTY2E8D
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
Cooling capacity (Nominal) kW 6,00 7,10 10,00 12,50 10,00 12,50 14,00
Cooling capacity (Min) kW 2,00 2,00 2,70 3,80 2,70 3,80 3,30
Cooling capacity (Max) kW 7,10 7,70 11,50 13,50 11,50 13,50 15,00
EER (Nominal) (1) W/W 3,68 3,21 3,01 3,01 3,01 3,01 2,98
EER (Min) (1) W/W 8,00 8,00 5,09 4,22 5,09 4,22 3,93
EER (Max) (1) W/W 3,16 2,91 2,65 2,62 2,65 2,62 2,63
SEER (2) 6,70 A++ 6,10 A++ 6,10 A++ 5,26 6,00 A+ 5,24 5,25
Pdesign (cooling) kW 6,00 7,10 10,00 12,50 10,00 12,50 14,00
Input power cooling (Nominal) kW 1,63 2,21 3,32 4,15 3,32 4,15 4,70
Input power cooling (Min) kW 0,25 0,25 0,53 0,90 0,53 0,90 0,84
Input power cooling (Max) kW 2,25 2,65 4,34 5,16 4,34 5,16 5,70
Annual energy consumption cooling (3) kWh/a 313 407 574 584
Heating capacity (Nominal) kW 6,00 7,10 10,00 12,50 10,00 12,50 14,00
Heating capacity (Min) kW 1,80 1,80 2,10 3,40 2,10 3,40 4,10
Heating capacity (Max) kW 7,00 8,10 13,80 15,00 13,80 15,00 16,00
Heating capacity at -7°C (4) kW 9,97 10,97 9,97 10,97 13,35
Heating capacity at -15°C (4) kW 8,43 9,03 8,43 9,03 12,38
COP (Nominal) (1) W/W 4,35 4,23 3,85 3,85 3,85 3,85 3,88
COP (Min) (1) W/W 9,00 9,00 5,12 4,66 5,12 4,66 4,56
COP (Max) (1) W/W 4,38 3,77 3,45 3,41 3,45 3,41 3,07
SCOP (2) 4,00 A+ 4,00 A+ 3,90 A 3,58 3,90 A 3,58 3,57
Pdesign at -10°C kW 6,00 6,00 10,00 12,50 10,00 12,50 14,00
Input power heating (Nominal) kW 1,38 1,68 2,60 3,25 2,60 3,25 3,61
Input power heating (Min) kW 0,20 0,20 0,41 0,73 0,41 0,73 0,90
Input power heating (Max) kW 1,60 2,15 4,00 4,40 4,00 4,40 5,21
Annual energy consumption heating (3) kWh/a 2100 2100 3590 3590
Indoor unit S-60PT2E5B S-71PT2E5B S-100PT2E5B S-125PT2E5B S-100PT2E5B S-125PT2E5B S-140PT2E5B
Indoor air flow (Hi) m³/min 20,00 21,00 30,00 34,00 30,00 34,00 35,00
Indoor air flow (Med) m³/min 17,00 18,00 25,00 28,00 25,00 28,00 29,00
Indoor air flow (Lo) m³/min 14,50 15,50 23,00 24,00 23,00 24,00 25,00
Indoor sound pressure (Hi) (5) dB(A) 38 39 42 46 42 46 47
Indoor sound pressure (Med) (5) dB(A) 34 35 37 40 37 40 41
Indoor sound pressure (Lo) (5) dB(A) 30 31 35 36 35 36 37
Indoor dimension (Height) mm 235 235 235 235 235 235 235
Indoor dimension (Width) mm 1275 1275 1590 1590 1590 1590 1590
Indoor dimension (Depth) mm 690 690 690 690 690 690 690
Indoor net weight kg 33 33 40 40 40 40 40
Outdoor unit U-60PEY2E5 U-71PEY2E5 U-100PEY1E5 U-125PEY1E5 U-100PEY1E8 U-125PEY1E8 U-140PEY1E8
Outdoor power source V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415
Outdoor recommended fuse A 25 30 16 16 16
Outdoor connection indoor / outdoor mm² 4,0 6,0 2,5 2,5 2,5
Current in cooling (1p 220V / 3p 380) A 8,00 10,80 15,60 19,70 5,30 6,50 7,40
Current in cooling (1p 230V / 3p 400) A 7,60 10,30 15,00 18,90 5,05 6,20 7,00
Current in cooling (1p 240V / 3p 415) A 7,30 9,85 14,40 18,10 4,85 6,00 6,80
Current in heating (1p 220V / 3p 380) A 6,70 8,20 11,90 15,20 4,10 5,10 5,65
Current in heating (1p 230V / 3p 400) A 6,45 7,85 11,50 14,60 3,90 4,80 5,35
Current in heating (1p 240V / 3p 415) A 6,15 7,50 11,10 13,90 3,75 4,65 5,15
Outdoor air flow (Cool) m³/min 38 44 110 80 76 80 135
Outdoor air flow (Heat) m³/min 41 41 95 73 67 73 120
Outdoor sound pressure (Cool -Hi) dB(A) 46 49 52 56 54 56 54
Outdoor sound pressure (Heat -Hi) dB(A) 48 49 52 56 54 56 53
Outdoor dimension (Height) mm 619 619 996 996 996 996 1416
Outdoor dimension (Width) mm 799 799 940 940 940 940 940
Outdoor dimension (Depth) mm 299 299 340 340 340 340 340
Outdoor net weight kg 40 40 73 85 73 85 98
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 50 5 ~ 50 5 ~ 50 5 ~ 50
Elevation difference (in/out) (5) m 30 30 30 30 30 30 30
Pipe length for additional gas m 30 30 30 30 30 30 30
Additional gas amount g/m 40 40 50 50 50 50 50
Refrigerant (R410A) / CO2 Eq. kg / T 1,95 / 4,0716 1,95 / 4,0716 2,60 / 5,4288 3,20 / 6,6816 2,60 / 5,4288 3,20 / 6,6816 3,40 / 7,0992
Operating range (Cool - Min) °C -10 -10 -10 -10 -10 -10 -10
Operating range (Cool - Max) °C +43 +43 +43 +43 +43 +43 +43
Operating range (Heat - Min) °C -15 -15 -15 -15 -15 -15 -15
Operating range (Heat - Max) °C +24 +24 +24 +24 +24 +24 +24

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) Heating capacity is calculated including defrost factor correction.
(5) The sound pressure of the units shows the value measured of the position 1 m in front of the main body and 1 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(6) When installing the outdoor unit at a higher position than the indoor unit.
* Recommended fuse for the indoor 3 A.