PACi Standard Low Static Pressure Hide Away • R32

The depth of only 250mm provides greater installation flexibility and the unit can be used in more applications. Ideal for sites with narrow ceiling voids.

Ultra-slim profile: 250mm height for all models.

  • Automatic learning function for the required static pressure on site during commissioning (a standard wired remote controller is required. S-60/71/100/125/140PN1E5B models only)
  • Compact indoor units without loosing static pressure (only 250 mm high)
  • 50 Pa static pressure
  • Easy maintenance and service via external electrical box
  • 3 speed centrifugal fan through wired or Infrared remote controller
  • DC FAN for better efficiency and control
  • Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB. The external device can be controlled by the remote control of the Panasonic indoor unit

Specifications

See all
PACi Standard Low Static Pressure Hide Away • R32 SINGLE PHASE THREE PHASE
60 kW 71 kW 100 kW 125 kW 140 kW 100 kW 125 kW 140 kW
EER (Nominal) (1) W/W 3,20 2,95 3,10 3,00 2,90 3,10 3,00 2,90
COP (Nominal) (1) W/W 3,80 3,60 3,70 3,60 3,55 3,70 3,60 3,55
Refrigerant (R32) / CO2 Eq. kg / T
Kit KIT-60PN1Z5 KIT-71PN1Z5 KIT-100PN1Z5 KIT-125PN1Z5 KIT-140PN1Z5 KIT-100PN1Z8 KIT-125PN1Z8 KIT-140PN1Z8
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
Cooling capacity (Nominal) kW 6,0 7,1 10,0 12,5 14,0 10,0 12,5 14,0
Cooling capacity (Min) kW 2,0 2,0 3,0 3,2 3,3 3,0 3,2 3,3
Cooling capacity (Max) kW 7,1 7,7 11,5 13,5 15,0 11,5 13,5 15,0
EER (Nominal) (1) W/W 3,31 3,11 3,30 3,20 3,00 3,30 3,21 3,01
SEER (2) 5,8 A+ 5,8 A+ 5,4 A 5,1 5 5,4 A 5,1 5
Pdesign (cooling) kW 6,0 7,1 10,0 12,5 14,0 10,0 12,5 14,0
Input power cooling (Nominal) kW 1,81 2,28 3,03 3,90 4,65 3,03 3,90 4,65
Annual energy consumption cooling (3) kWh/a 361 428 641 648
Heating capacity (Nominal) kW 6,0 7,1 10,0 12,5 14,0 10,0 12,5 14,0
Heating capacity (Min) kW 1,8 1,8 3,0 3,3 3,4 3,0 3,3 3,4
Heating capacity (Max) kW 7,0 8,1 14,0 15,0 16,0 14,0 15,0 16,0
COP (Nominal) (1) W/W 3,90 3,72 3,91 3,60 3,55 3,91 3,61 3,55
SCOP (2) 4,0 A+ 4,0 A+ 3,9 A 3,6 3,5 3,9 A 3,6 3,5
Pdesign at -10°C kW 5,6 5,6 7,6 12,5 14,0 7,6 12,5 14,0
Input power heating (Nominal) kW 1,54 1,90 2,56 3,46 3,94 2,56 3,46 3,94
Annual energy consumption heating (3) kWh/a 2095 2100 3589 3589
Indoor unit S-60PN1E5B S-71PN1E5B S-100PN1E5B S-125PN1E5B S-140PN1E5B S-100PN1E5B S-125PN1E5B S-140PN1E5B
External static pressure (Nominal) (4) Pa 25 25 40 50 50 40 50 50
External static pressure (Min) (4) Pa 10 10 10 10 10 10 10 10
External static pressure (Max) (4) Pa 80 80 80 80 80 80 80 80
Indoor air flow (Hi) m³/min 22,0 22,0 36,0 38,0 40,0 36,0 38,0 40,0
Indoor air flow (Med) m³/min 20,0 20,0 33,0 35,0 37,0 33,0 35,0 37,0
Indoor air flow (Lo) m³/min 16,0 16,0 26,0 28,0 30,0 26,0 28,0 30,0
Indoor sound pressure (Hi) (5) dB(A) 38 38 39 40 41 39 40 41
Indoor sound pressure (Med) (5) dB(A) 36 36 37 38 39 37 38 39
Indoor sound pressure (Lo) (5) dB(A) 31 31 32 33 34 32 33 34
Indoor dimension (Height) mm 250 250 250 250 250 250 250 250
Indoor dimension (Width) mm 1000 1000 1200 1200 1200 1200 1200 1200
Indoor dimension (Depth) mm 650 650 650 650 650 650 650 650
Indoor net weight kg 32 32 41 41 41 41 41 41
Outdoor unit U-60PZ2E5 U-71PZ2E5 U-100PZ2E5 U-125PZ2E5 U-140PZ2E5 U-100PZ2E8 U-125PZ2E8 U-140PZ2E8
Outdoor power source V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 8,30 10,60 14,00 17,90 21,50 4,70 6,00 7,20
Current in cooling (1p 230V / 3p 400) A 8,00 10,10 13,30 17,10 20,50 4,50 5,70 6,80
Current in cooling (1p 240V / 3p 415) A 7,60 9,60 12,80 16,50 19,60 4,30 5,50 6,60
Current in heating (1p 220V / 3p 380) A 7,00 8,80 11,60 15,80 18,00 3,90 5,30 6,00
Current in heating (1p 230V / 3p 400) A 6,70 8,40 11,10 15,10 17,30 3,70 5,00 5,70
Current in heating (1p 240V / 3p 415) A 6,40 8,00 10,70 14,50 16,50 3,60 4,90 5,50
Outdoor air flow (Cool) m³/min 40 50 76 86 89 76 86 89
Outdoor air flow (Heat) m³/min 45 45 70 78 83 70 78 83
Outdoor sound pressure (Cool -Hi) dB(A) 46 49 52 55 56 52 55 56
Outdoor sound pressure (Heat -Hi) dB(A) 48 49 52 55 56 52 55 56
Outdoor sound power (Cool -Hi) dB(A) 65 69 70 73 74 70 73 74
Outdoor sound power (Heat -Hi) dB(A) 68 69 70 73 74 70 73 74
Outdoor dimension (Height) mm 695 695 996 996 996 996 996 996
Outdoor dimension (Width) mm 875 875 980 980 980 980 980 980
Outdoor dimension (Depth) mm 320 320 370 370 370 370 370 370
Outdoor net weight kg 44 44 90 94 94 90 94 94
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 50 5 ~ 50 5 ~ 50 5 ~ 50 5 ~ 50
Elevation difference (in/out) (6) m 30 30 30 30 30 30 30 30
Pipe length for additional gas m 30 30 30 30 30 30 30 30
Additional gas amount g/m 35 35 45 45 45 45 45 45
Refrigerant (R32) / CO2 Eq. kg / T 1,45 / 0,979 1,45 / 0,979 2,60 / 1,755 2,98 / 2,0115 2,98 / 2,0115 2,60 / 1,755 2,98 / 2,0115 2,98 / 2,0115
Operating range (Cool - Min) °C -10 -10 -10 -10 -10 -10 -10 -10
Operating range (Cool - Max) °C 43 43 43 43 43 43 43 43
Operating range (Heat - Min) °C -15 -15 -15 -15 -15 -15 -15 -15
Operating range (Heat - Max) °C 24 24 24 24 24 24 24 24

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) Medium external static pressure setting from factory.
(5) The sound pressure of the units shows the value measured of the position 1,5 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(6) When installing the outdoor unit at a higher position than the indoor unit.
* Recommended fuse for the indoor 3 A.