PACi Standard Wall Mounted • R410A

The extension of the range to include a 10kW unit allows for many more applications such as studios, gyms, high ceiling areas and even computer server rooms.

The unit’s compact design and flat face ensure discreet installation, even in a small space.

  • Modern design with flat face and compact size
  • Stylish matt white color
  • DC FAN for better efficiency and control
  • Six directional piping outlet
  • Datanavi simple support tool App with remote controller (CZ-RTC5B)
  • Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB. The external device can be controlled by the remote control of the Panasonic indoor unit

Specifications

See all
PACi Standard Wall Mounted • R410A SINGLE PHASE THREE PHASE
61 kW 71 kW 90 kW 9 kW
EER (Nominal) (1) W/W 3,47 (6,67 - 3,02) A 2,90 (6,67 - 2,61) C 2,67 (5,09 - 2,55) D 2,67 (5,09 - 2,55) D
COP (Nominal) (1) W/W 4,30 (9,00 - 4,12) A 4,20 (9,00 - 3,60) A 3,78 (5,12 - 3,50) A 3,78 (5,12 - 3,50) A
Kit KIT-60PKY2E5D KIT-71PKY2E5D KIT-100PKY2E5D KIT-100PKY2E8D
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
Cooling capacity (Nominal) kW 6,10 7,10 9,00 9,00
Cooling capacity (Min) kW 2,00 2,00 2,70 2,70
Cooling capacity (Max) kW 7,10 7,70 9,70 9,70
EER (Nominal) (1) W/W 3,47 2,90 2,67 2,67
EER (Min) (1) W/W 6,67 6,67 5,09 5,09
EER (Max) (1) W/W 3,02 2,61 2,55 2,55
SEER (2) 5,70 A+ 5,40 A 5,90 A+ 5,80 A+
Pdesign (cooling) kW 6,10 7,10 9,00 9,00
Input power cooling (Nominal) kW 1,76 2,45 3,37 3,37
Input power cooling (Min) kW 0,30 0,30 0,53 0,53
Input power cooling (Max) kW 2,35 2,95 3,80 3,80
Annual energy consumption cooling (3) kWh/a 375 460 534 543
Heating capacity (Nominal) kW 6,10 7,10 9,00 9,00
Heating capacity (Min) kW 1,80 1,80 2,10 2,10
Heating capacity (Max) kW 7,00 8,10 10,50 10,50
Heating capacity at -7°C (4) kW 9,97 9,97
Heating capacity at -15°C (4) kW 8,43 8,43
COP (Nominal) (1) W/W 4,30 4,20 3,78 3,78
COP (Min) (1) W/W 9,00 9,00 5,12 5,12
COP (Max) (1) W/W 4,12 3,60 3,50 3,50
SCOP (2) 4,00 A+ 4,00 A+ 3,90 A 3,90 A
Pdesign at -10°C kW 6,00 6,00 9,00 9,00
Input power heating (Nominal) kW 1,42 1,69 2,38 2,38
Input power heating (Min) kW 0,20 0,20 0,41 0,41
Input power heating (Max) kW 1,70 2,25 3,00 3,00
Annual energy consumption heating (3) kWh/a 2100 2100 3231 3231
Indoor unit S-60PK2E5B S-71PK2E5B S-100PK2E5B S-100PK2E5B
Indoor air flow (Hi) m³/min 20,00 20,00 22,00 22,00
Indoor air flow (Med) m³/min 17,50 17,50 18,50 18,50
Indoor air flow (Lo) m³/min 14,50 14,50 15,00 15,00
Indoor sound pressure (Hi) (5) dB(A) 47 47 49 49
Indoor sound pressure (Med) (5) dB(A) 44 44 45 45
Indoor sound pressure (Lo) (5) dB(A) 40 40 41 41
Indoor dimension (Height) mm 302 302 302 302
Indoor dimension (Width) mm 1120 1120 1120 1120
Indoor dimension (Depth) mm 236 236 236 236
Indoor net weight kg 14 14 14 14
Outdoor unit U-60PEY2E5 U-71PEY2E5 U-100PEY1E5 U-100PEY1E8
Outdoor power source V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415
Outdoor recommended fuse A 25 16
Outdoor connection indoor / outdoor mm² 4,0 2,5
Current in cooling (1p 220V / 3p 380) A 8,60 12,00 16,00 5,40
Current in cooling (1p 230V / 3p 400) A 8,20 11,40 15,30 5,10
Current in cooling (1p 240V / 3p 415) A 7,85 11,00 14,60 4,95
Current in heating (1p 220V / 3p 380) A 6,85 8,25 10,90 3,75
Current in heating (1p 230V / 3p 400) A 6,55 7,85 10,60 3,55
Current in heating (1p 240V / 3p 415) A 6,30 7,55 10,10 3,45
Outdoor air flow (Cool) m³/min 38 44 76 76
Outdoor air flow (Heat) m³/min 41 41 67 67
Outdoor sound pressure (Cool -Hi) dB(A) 46 49 54 54
Outdoor sound pressure (Heat -Hi) dB(A) 48 49 54 54
Outdoor sound power (Heat -Hi) dB(A) 48 49 54
Outdoor dimension (Height) mm 619 619 996 996
Outdoor dimension (Width) mm 799 799 940 940
Outdoor dimension (Depth) mm 299 299 340 340
Outdoor net weight kg 40 40 73 73
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 50
Elevation difference (in/out) (5) m 30 30 30 30
Pipe length for additional gas m 30 30 30 30
Additional gas amount g/m 40 40 50 50
Refrigerant (R410A) / CO2 Eq. kg / T 1,95 / 4,0716 1,95 / 4,0716 2,60 / 5,4288 2,60 / 5,4288
Operating range (Cool - Min) °C -10 -10 -10 -10
Operating range (Cool - Max) °C +43 +43 +43 +43
Operating range (Heat - Min) °C -15 -15 -15 -15
Operating range (Heat - Max) °C +24 +24 +24 +24

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) Heating capacity is calculated including defrost factor correction.
(5) The sound pressure of the units shows the value measured of the position 1 m in front of the main body and 1 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
6) When installing the outdoor unit at a higher position than the indoor unit.
* Recommended fuse for the indoor 3 A.