27.7kW

LCU-KSC280M08

iCOOL LCU serija za MT primjene

Varijacija iCOOL-a za ispunjavanje zahtjevnih uvjeta instalacijskog okruženja.

Visokoučinkovita baza inverterskog kompresora za komercijalne instalacije. Dizajnirana za MT primjene. Opremljena hermetičkim spiralnim ili rotacijskim kompresorom. Savršena za primjenu s niskom razinom buke i u središtu grada.

Uvedite se s daljinskim, lokalno isporučenim kondenzatorom.

Specifikacije

Prikaži sve
iCOOL LCU serija – MT
27.7 kW
Model LCU-KSC280M08
Kompresori Tandem kompresor
Compatible refrigerants R448A, R449A, R134a, R513A
Kapacitet grijanja (A -7 °C, Š 35 °C) CAT II
Application and nominal cooling capacity MT/LT (kW) MT (27,7)
MT (R449A/R448A) - Cooling capacity at .
ET -15°C, CT 40°C (Min - Max) kW 4,0 - 24,5
ET -15°C, CT 45°C (Min - Max) kW 3,7 - 22,4
ET -15°C, CT 50°C (Min - Max) kW 3,3 - 20,4
ET -10°C, CT 40°C (Min - Max) kW 5,0 - 30,5
ET -10°C, CT 45°C (Min - Max) kW 4,6 - 27,7
ET -10°C, CT 50°C (Min - Max) kW 4,2 - 25,2
ET -5°C, CT 40°C (Min - Max) kW 6,2 - 37,9
ET -5°C, CT 45°C (Min - Max) kW 5,7 - 34,4
ET -5°C, CT 50°C (Min - Max) kW 5,2 - 31,2
MT (R134a/R513A) - Cooling capacity at .
ET -15°C; CT 40°C (Min - Max) kW 2,0 - 15,9
ET -15°C; CT 45°C (Min - Max) kW 1,7 - 14,6
ET -15°C; CT 50°C (Min - Max) kW 3,3 - 20,4
ET -10°C; CT 45°C (Min - Max) kW 2,3 - 18,1
ET -10°C; CT 50°C (Min - Max) kW 2,0 - 16,4
ET -5°C; CT 40°C (Min - Max) kW 6,2 - 37,9
ET -5°C; CT 45°C (Min - Max) kW 5,7 - 34,4
ET -5°C; CT 50°C (Min - Max) kW 5,2 - 31,2
Nominal operating current at ET -10°C MT / -30°C LT AT 32°C and 230 - 400V 50Hz A 28,7
Maximum operating current (in the most loaded phase at 400V 50Hz) A 38,4
Maximum power consumption kW 20,4
Dimenzije (Didite) mm 1.650
Dimenzije (visina) mm 975
Dimenzije (Depth) mm 649
Neto težina kg 301
Sound level at 10m dB(A) 52,0
Oil charge dm³ 2,0 + 2,8 + 2x0,6
Connections (Suction) Inch (mm) 1 3/8
Connections (Liquid) Inch (mm) 7/8
Liquid receiver dm³ 14
Duljina priključnog cjevovoda m 70
Maximum height distance (Evaporator above) m 12
Maximum height distance (Evaporator below) m 12
Which pipes needs to be insulated (Suction / liquid / both) Suction
Recommended insulation thickness mm 13
Maximum quantity of evaporators connected Qty. 10
Temperatura isparavanja (Min) °C -15
Temperatura isparavanja (Max) °C 10
Temperatura okoline (Min) °C -20
Temperatura okoline (Max) °C 43
Compressor - additional data .
Compressor model C-SBVN373L0B/ C-SCN603H8T
Volumetric flow m³/h 7,7 - 24,6 / 23,6
Rotation range rps 31-80
Current (Full load amperage) A 18,4 / 16,0
Current (Peak current limit / Locked rotor amperage) A 46 / 80
Oil type FV68S (PVE)
Crankcase heater power consumption W 2x90
CU power supply .
Voltage V / ph / Hz 3x400 / 50 PE+N (TN-S)
Recommended minimum cable cross-section mm² 5x10,0
Recommended minimum protection C50

* ET: Temperatura isparavanja. CT: Temperatura kondenzacije.