Aquarea Air Smart ventilokonvektor samostojeći

3.30kW

P-FAL35

Aquarea Air Smart ventilokonvektor samostojeći

Dizajnirani za pružanje grijanja i hlađenja u jednoj kompaktnoj jedinici, Aquarea Air Smart ventilokonvektori maksimiziraju uštedu energije u kombinaciji s dizalicama topline Aquarea.

Specifikacije

Prikaži sve
Aquarea Air Smart ventilokonvektor samostojeći
3.30 kW
Model P-FAL35
Fan speed (1) Min / Med / Max
Total cooling capacity (Min) (2) kW 1,32
Total cooling capacity (Med) (2) kW 2,39
Total cooling capacity (Max) (2) kW 3,30
Sensible capacity (Min) (2) kW 1,02
Sensible capacity (Med) (2) kW 1,84
Sensible capacity (Max) (2) kW 2,65
Water flow cooling (Min) (2) l/h 226,15
Water flow cooling (Med) (2) l/h 409,48
Water flow cooling (Max) (2) l/h 565,39
Water pressure drop cooling (Min) (2) kPa 2,5
Water pressure drop cooling (Med) (2) kPa 8,8
Water pressure drop cooling (Max) (2) kPa 18,0
Heating capacity (Min) (3) kW 1,45
Heating capacity (Med) (3) kW 2,56
Heating capacity (Max) (3) kW 3,73
Water flow heating (Min) (3) l/h 259,22
Water flow heating (Med) (3) l/h 456,72
Water flow heating (Max) (3) l/h 671,86
Water pressure drop heating (Min) (3) kPa 3,0
Water pressure drop heating (Med) (3) kPa 8,9
Water pressure drop heating (Max) (3) kPa 21,2
Razine zvuka .
Sound power (Min) dB(A) 37
Snaga zvuka (Med) dB(A) 47
Sound power (Max) dB(A) 55
Sound pressure (Min) (4) dB(A) 26
Sound pressure (Med) (4) dB(A) 35
Sound pressure (Max) (4) dB(A) 46
Ventilation .
Broj obožavatelja 1
Air flow (Min) m³/h 302
Protok zraka (Med) m³/min 410
Protok zraka (Max) m³/h 567
Single zone air flow (Min) m³/h 13
Električni podaci .
Napajanje (Voltage) V 230
Napajanje (faza) 1
Napajanje (frekvencija) Hz 50
Consumption (Min) W 18,0
Consumption (Med) W 22,0
Consumption (Max) W 26,5
Priključci vode ventilakonvektori .
Hydraulic connections type Eurokonus
Hydraulic connections Inch ¾
Dimenzije i težina .
Dimenzije (visina) mm 580
Dimenzije (Didite) mm 1.280
Dimenzije (Depth) mm 119
Neto težina kg 20

1) Standardne tvornički postavljene brzine ventilatora.
2) Prema Eurovent standardu. Zrak: 27°C DB/19°C WB, ohlađena voda: 7°C/12°C (za podatke o padu tlaka vode: gubitak tlaka odgovarajućim nominalnim protokom).
3) Prema Eurovent standardu. Zrak: 20°C, topla voda: 45°C/40°C. Gubitak tlaka pri odgovarajućem nazivnom protoku (za podatke o padu tlaka vode: gubitak tlaka pri odgovarajućem nazivnom protoku).
4) Informativni podaci
, s obzirom na hipotetsko prigušenje zvuka prostorije i instalacije od 9dB(A).

Aktualnosti