Modelle
The ducted systems are the ideal solution for flexible, concealed air conditioning and the optional 200mm spigots ensure simple, hassle-free connection to spiral ductwork.
- High ESP (external static pressure) up to 150 Pa
- Automatic learning function for the required static pressure on site during commissioning (a standard wired remote controller is required)
- DC FAN for better efficiency and control
- Built in drain pump
- Datanavi simple support tool App with remote controller (CZ-RTC5B)
- Twin split options
- Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB. The external device can be controlled by the remote control of the Panasonic indoor unit
PACi Standard und Elite:
Zwei bedarfsgerechte Lösungen für Geschäfts-, Büro- und Wohngebäude
Technische Daten
PACi Standard | R32 | PF Kanalgeräte | Einphasig | Dreiphasig | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
60 kW | 71 kW | 100 kW | 125 kW | 140 kW | 100 kW | 125 kW | 140 kW | |||
EER (Nominal) (1) | W/W | 3,49 | 3,66 (5,36 - 2,81) A | 3,52 (5,33 - 2,80) A | 3,18 (5,32 - 2,70) B | 3,66 (5,36 - 2,81) A | 3,52 (5,33 - 2,80) A | 3,18 (5,32 - 2,70) B | ||
COP (Nominal) (1) | W/W | 4,55 | 4,31 (5,36 - 3,51) A | 4,02 (5,50 - 3,45) A | 3,79 (5,48 - 3,13) A | 4,31 (5,36 - 3,51) A | 4,02 (5,50 - 3,45) A | 3,79 (5,48 - 3,13) A | ||
Refrigerant (R32) / CO2 Eq. | kg / T | — | 2,60 / 1,755 | 2,98 / 2,0115 | 2,98 / 2,0115 | 2,60 / 1,755 | 2,98 / 2,0115 | 2,98 / 2,0115 | ||
Kit | KIT-60PF1Z5 | KIT-71PF1Z5 | KIT-100PF1Z5 | KIT-125PF1Z5 | KIT-140PF1Z5 | KIT-100PF1Z8 | KIT-125PF1Z8 | KIT-140PF1Z8 | ||
Remote controller | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | ||
Cooling capacity (Nominal) | kW | 6,0 | 7,1 | 10,0 | 12,5 | 14,0 | 10,0 | 12,5 | 14,0 | |
Cooling capacity (Min) | kW | 2,0 | 2,0 | 3,0 | 3,2 | 3,3 | 3,0 | 3,2 | 3,3 | |
Cooling capacity (Max) | kW | 7,1 | 7,7 | 11,5 | 13,5 | 15,0 | 11,5 | 13,5 | 15,0 | |
EER (Nominal) (1) | W/W | 3,51 | 3,23 | 3,66 | 3,52 | 3,18 | 3,66 | 3,52 | 3,18 | |
EER (Min) (1) | W/W | 5,36 | 5,33 | 5,32 | 5,36 | 5,33 | 5,32 | |||
EER (Max) (1) | W/W | 2,81 | 2,80 | 2,70 | 2,81 | 2,80 | 2,70 | |||
SEER (2) | 6,1 A++ | 6,1 A++ | 5,6 A+ | 5,6 | 5,4 | 5,6 A+ | 5,6 | 5,4 | ||
Pdesign (cooling) | kW | 6,0 | 7,1 | 10,0 | 12,5 | 14,0 | 10,0 | 12,5 | 14,0 | |
Input power cooling (Nominal) | kW | 1,71 | 2,20 | 2,73 | 3,55 | 4,40 | 2,73 | 3,55 | 4,40 | |
Input power cooling (Min) | kW | 0,56 | 0,60 | 0,62 | 0,56 | 0,60 | 0,62 | |||
Input power cooling (Max) | kW | 4,09 | 4,82 | 5,56 | 4,09 | 4,82 | 5,56 | |||
Annual energy consumption cooling (3) | kWh/a | 344 | 407 | 625 | 787 | 911 | 625 | 790 | 912 | |
Heating capacity (Nominal) | kW | 6,0 | 7,1 | 10,0 | 12,5 | 14,0 | 10,0 | 12,5 | 14,0 | |
Heating capacity (Min) | kW | 1,8 | 1,8 | 3,0 | 3,3 | 3,4 | 3,0 | 3,3 | 3,4 | |
Heating capacity (Max) | kW | 7,0 | 8,1 | 14,0 | 15,0 | 16,0 | 14,0 | 15,0 | 16,0 | |
COP (Nominal) (1) | W/W | 4,55 | 4,13 | 4,31 | 4,02 | 3,79 | 4,31 | 4,02 | 3,79 | |
COP (Min) (1) | W/W | 5,36 | 5,50 | 5,48 | 5,36 | 5,50 | 5,48 | |||
COP (Max) (1) | W/W | 3,51 | 3,45 | 3,13 | 3,51 | 3,45 | 3,13 | |||
SCOP (2) | 4,2 A+ | 4,3 A+ | 3,8 A | 3,6 | 3,5 | 3,8 A | 3,6 | 3,5 | ||
Pdesign at -10°C | kW | 6,0 | 6,0 | 10,0 | 12,5 | 13,6 | 10,0 | 12,5 | 13,6 | |
Input power heating (Nominal) | kW | 1,32 | 1,72 | 2,32 | 3,11 | 3,69 | 2,32 | 3,11 | 3,69 | |
Input power heating (Min) | kW | 0,56 | 0,60 | 0,62 | 0,56 | 0,60 | 0,62 | |||
Input power heating (Max) | kW | 3,99 | 4,35 | 5,12 | 3,99 | 4,35 | 5,12 | |||
Annual energy consumption heating (3) | kWh/a | 2000 | 1953 | 3684 | 4848 | 5379 | 3684 | 4848 | 5379 | |
Indoor unit | S-60PF1E5B | S-71PF1E5B | S-100PF1E5B | S-125PF1E5B | S-140PF1E5B | S-100PF1E5B | S-125PF1E5B | S-140PF1E5B | ||
External static pressure (Nominal) (4) | Pa | 70 | 70 | 100 | 100 | 100 | 100 | 100 | 100 | |
External static pressure (Min) (4) | Pa | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | |
External static pressure (Max) (4) | Pa | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | |
Indoor air flow (Hi) | m³/min | 21,0 | 21,0 | 32,0 | 34,0 | 36,0 | 32,0 | 34,0 | 36,0 | |
Indoor air flow (Med) | m³/min | 19,0 | 19,0 | 26,0 | 29,0 | 32,0 | 26,0 | 29,0 | 32,0 | |
Indoor air flow (Lo) | m³/min | 15,0 | 15,0 | 21,0 | 23,0 | 25,0 | 21,0 | 23,0 | 25,0 | |
Moisture removal volume | L/h | 3,4 | 4,2 | 6,0 | 7,9 | 9,0 | 6,0 | 7,9 | 9,0 | |
Indoor sound pressure (Hi) (5) | dB(A) | 35 | 35 | 38 | 39 | 40 | 38 | 39 | 40 | |
Indoor sound pressure (Med) (5) | dB(A) | 32 | 32 | 34 | 35 | 36 | 34 | 35 | 36 | |
Indoor sound pressure (Lo) (5) | dB(A) | 26 | 26 | 31 | 32 | 33 | 31 | 32 | 33 | |
Indoor sound power (Hi) | dB(A) | 57 | 57 | 60 | 61 | 62 | 60 | 61 | 62 | |
Indoor sound power (Med) | dB(A) | 54 | 54 | 56 | 57 | 58 | 56 | 57 | 58 | |
Indoor sound power (Lo) | dB(A) | 48 | 48 | 53 | 54 | 55 | 53 | 54 | 55 | |
Indoor dimension (Height) | mm | 290 | 290 | 290 | 290 | 290 | 290 | 290 | 290 | |
Indoor dimension (Width) | mm | 1000 | 1000 | 1400 | 1400 | 1400 | 1400 | 1400 | 1400 | |
Indoor dimension (Depth) | mm | 700 | 700 | 700 | 700 | 700 | 700 | 700 | 700 | |
Indoor net weight | kg | 33 | 33 | 45 | 45 | 45 | 45 | 45 | 45 | |
Outdoor unit | U-60PZ2E5 | U-71PZ2E5 | U-100PZ2E5 | U-125PZ2E5 | U-140PZ2E5 | U-100PZ2E8 | U-125PZ2E8 | U-140PZ2E8 | ||
Outdoor power source | V | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | |
Current in cooling (1p 220V / 3p 380) | A | 8,05 | 10,40 | 12,10 | 16,10 | 20,20 | 4,15 | 5,40 | 6,75 | |
Current in cooling (1p 230V / 3p 400) | A | 7,70 | 9,95 | 11,60 | 15,50 | 19,30 | 3,95 | 5,10 | 6,40 | |
Current in cooling (1p 240V / 3p 415) | A | 7,35 | 9,50 | 11,10 | 14,80 | 18,60 | 3,80 | 4,95 | 6,15 | |
Current in heating (1p 220V / 3p 380) | A | 6,05 | 8,10 | 10,10 | 14,00 | 16,80 | 3,45 | 4,70 | 5,60 | |
Current in heating (1p 230V / 3p 400) | A | 5,80 | 7,75 | 9,70 | 13,40 | 16,00 | 3,30 | 4,45 | 5,30 | |
Current in heating (1p 240V / 3p 415) | A | 5,55 | 7,40 | 9,30 | 12,90 | 15,30 | 3,20 | 4,30 | 5,15 | |
Outdoor air flow (Cool) | m³/min | 40 | 50 | 76 | 86 | 89 | 76 | 86 | 89 | |
Outdoor air flow (Heat) | m³/min | 45 | 45 | 70 | 78 | 83 | 70 | 78 | 83 | |
Outdoor sound pressure (Cool -Hi) | dB(A) | 46 | 49 | 52 | 55 | 56 | 52 | 55 | 56 | |
Outdoor sound pressure (Heat -Hi) | dB(A) | 48 | 49 | 52 | 55 | 56 | 52 | 55 | 56 | |
Outdoor sound power (Cool -Hi) | dB(A) | 65 | 69 | 70 | 73 | 74 | 70 | 73 | 74 | |
Outdoor sound power (Heat -Hi) | dB(A) | 68 | 69 | 70 | 73 | 74 | 70 | 73 | 74 | |
Outdoor dimension (Height) | mm | 695 | 695 | 996 | 996 | 996 | 996 | 996 | 996 | |
Outdoor dimension (Width) | mm | 875 | 875 | 980 | 980 | 980 | 980 | 980 | 980 | |
Outdoor dimension (Depth) | mm | 320 | 320 | 370 | 370 | 370 | 370 | 370 | 370 | |
Outdoor net weight | kg | 44 | 44 | 90 | 94 | 94 | 90 | 94 | 94 | |
Pipe diameter (Liquid) | Inch (mm) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | |
Pipe diameter (Gas) | Inch (mm) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | |
Pipe length range | m | 3 ~ 40 | 3 ~ 40 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | |
Elevation difference (in/out) (6) | m | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
Pipe length for additional gas | m | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
Additional gas amount | g/m | 35 | 35 | 45 | 45 | 45 | 45 | 45 | 45 | |
Refrigerant (R32) / CO2 Eq. | kg / T | 1,45 / 0,979 | 1,45 / 0,979 | 2,60 / 1,755 | 2,98 / 2,0115 | 2,98 / 2,0115 | 2,60 / 1,755 | 2,98 / 2,0115 | 2,98 / 2,0115 | |
Operating range (Cool - Min) | °C | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | |
Operating range (Cool - Max) | °C | 43 | 43 | 43 | 43 | 43 | 43 | 43 | 43 | |
Operating range (Heat - Min) | °C | -15 | -15 | -15 | -15 | -15 | -15 | -15 | -15 | |
Operating range (Heat - Max) | °C | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) Medium External static pressure setting from factory.
(5) The sound pressure of the units shows the value measured of the position 1,5 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(6) When installing the outdoor unit at a higher position than the indoor unit.
* Recommended fuse for the indoor 3 A.