Jednostki kanałowe z 2 wariantami montażu serii PACi Standard – PF3 • Czynnik R32

Nowe jednostki kanałowe z 2 wariantami montażu – PF3 do układów PACi z czynnikiem R32

2 warianty montażu (w poziomie / w pionie) i wysokie zewnętrzne ciśnienie statyczne 150 Pa stwarzają elastyczne możliwości wykonania instalacji.

Naturalny balans w Twoim domu

Dane techniczne

Zobacz wszystko
Jednostki kanałowe z 2 wariantami montażu serii PACi Standard – PF3 • Czynnik R32
10.0 kW
Kit KIT-100PF3Z28
Remote controller CZ-RTC6
Cooling capacity (Nominal) kW 9,5
Cooling capacity (Min) kW 3,0
Cooling capacity (Max) kW 11,4
EER (Nominal) (1) W/W 3,57
EER (Min) (1) W/W 6,00
EER (Max) (1) W/W 2,36
SEER/ηsc (2) % 6,5 A++
Pdesign (cooling) kW 9,5
Input power cooling (Nominal) kW 2,66
Input power cooling (Min) kW 0,50
Input power cooling (Max) kW 4,84
Annual energy consumption cooling (3) kWh/a 508
Heating capacity (Nominal) kW 9,5
Heating capacity (Min) kW 3,0
Heating capacity (Max) kW 13,5
COP (Nominal) (1) W/W 4,09
COP (Min) (1) W/W 6,00
COP (Max) (1) W/W 3,00
SCOP/ηsc (2) % 3,9 A
Pdesign at -10°C kW 7,8
Input power heating (Nominal) kW 2,32
Input power heating (Min) kW 0,50
Input power heating (Max) kW 4,50
Annual energy consumption heating (3) kWh/a 2795
Indoor unit S-1014PF3E
External static pressure (Nominal) (4) Pa 40
External static pressure (Min) (4) Pa 10
External static pressure (Max) (4) Pa 150
Moisture removal volume L/h 3,2
Indoor air flow (Hi) m³/min 32,0
Indoor air flow (Med) m³/min 26,0
Indoor air flow (Lo) m³/min 21,0
Indoor sound pressure (Hi) (5) dB(A) 33
Indoor sound pressure (Med) (5) dB(A) 29
Indoor sound pressure (Lo) (5) dB(A) 25
Indoor sound power (Hi) dB(A) 56
Indoor sound power (Med) dB(A) 52
Indoor sound power (Lo) dB(A) 48
Indoor dimension (Height) mm 250
Indoor dimension (Width) mm 1400
Indoor dimension (Depth) mm 730
Indoor net weight kg 39
nanoe X Generator Mark 2
Outdoor unit U-100PZ2E8
Outdoor power source V 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 4,15
Current in cooling (1p 230V / 3p 400) A 3,95
Current in cooling (1p 240V / 3p 415) A 3,80
Current in heating (1p 220V / 3p 380) A 3,60
Current in heating (1p 230V / 3p 400) A 3,40
Current in heating (1p 240V / 3p 415) A 3,30
Outdoor air flow (Cool) m³/min 76
Outdoor air flow (Heat) m³/min 70
Outdoor sound pressure (Cool -Hi) dB(A) 52
Outdoor sound pressure (Heat -Hi) dB(A) 52
Outdoor sound power (Cool -Hi) dB(A) 70
Outdoor sound power (Heat -Hi) dB(A) 70
Outdoor dimension (Height) mm 996
Outdoor dimension (Width) mm 980
Outdoor dimension (Depth) mm 370
Outdoor net weight kg 90
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 50
Elevation difference (in/out) (6) m 30
Pipe length for additional gas m 30
Additional gas amount g/m 45
Refrigerant (R32) / CO2 Eq. kg / T 2,60 / 1,755
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C +43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C +24
(1) Wskaźniki EER i COP obliczone zgodnie z normą EN 14511.
(2) Etykieta energetyczna w skali od A+++ do D. W przypadku modeli o mocy poniżej 12 kW wskaźniki SEER i SCOP obliczono według wartości podanych w rozporządzeniu (UE) nr 626/2011. W przypadku modeli o mocy powyżej 12 kW wartości ηsc / ηsh obliczono w oparciu o normę EN 14825.
(3) Roczne zużycie energii obliczono zgodnie z rozporządzeniem (UE) 626/2011.
(4) Umiarkowane zewnętrzne ciśnienie statyczne ustawione fabrycznie.
(5) Podane poziomy ciśnienia akustycznego odnoszą się do wartości zmierzonych na wysokości 1,5 m poniżej jednostki. Ciśnienie akustyczne mierzono zgodnie ze specyfikacją Eurovent 6/C/006-97.
(6) Jednostka zewnętrzna zainstalowana wyżej niż jednostka wewnętrzna.
* Zalecany bezpiecznik do jednostki wewnętrznej: 3 A.
** Wartości uzyskiwane przy standardowym wariancie montażu (montaż poziomy w suficie, wlot powietrza od tyłu) i wyłączonym generatorze nanoe™ X.