T-CAP stand-alone M-serie 1 fase - 3 fase - R290
25kW
WH-WXG25ME8 + CZ-RTW2TAW1C
Aquarea T-CAP M Series
Aquarea T-CAP M Series combines reliable heating performance, whisper-quiet operation and high water outlet temperatures in one advanced solution. Designed for both new-build and renovation projects, it delivers dependable comfort even in demanding winter conditions.
- Up to 75°C water outlet down to -15°C outdoor 1)
- Quiet operation: Only 29dB(A) sound pressure at 5m 2)
- Reliable outdoor units with Panasonic compressor, operating down to -28°C outdoor 3)
- T-CAP technology: Keeping heating capacity down to -20°C
- Panasonic Comfort Cloud App and Aquarea Service Cloud included
- Flexible integration into heating installations
- Flexible installation without an indoor unit
1) Down to 15ºC outdoor for 20, 25 and 30kW models.
2) Sound pressure calculation for WH-WXG12ME5, free standing, A +7°C, W 35°C in Quite mode 3.
3) Down to -25ºC outdoor for 20, 25 and 30kW models.
Aquarea Service Cloud. Controle voor vandaag en voor de toekomst
Aquarea Service Cloud. Controle voor vandaag en voor de toekomst
Specificaties
| T-CAP stand-alone M-serie 1 fase - 3 fase - R290 | |||
|---|---|---|---|
| 25 kW | |||
| Werkingsbereik - Buitenomgeving (Warmte) | °C | -25 ~ +35 | |
| Verwarming warm klimaat. Energieklasse (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A+++ | |
| Verwarming koud klimaat. Seizoensgebonden energie-efficiëntie η (W 35°C / W 55°C) | ηs % | 123 / 105 | |
| Verwarming koud klimaat. Seizoensgebonden energie-efficiëntie SCOP (W 35°C / W 55°C) | SCOP | 3,16 / 2,71 | |
| Verwarming koud klimaat. Energieklasse (W 35°C / W 55°C) (1) | A+++ to D | A+ / A+ | |
| Pomp van klasse A (aantal snelheden) | Variable speed | ||
| Pomp van klasse A (ingangsvermogen min.) | W | 230 | |
| Verwarmingswaterdebiet (∆T=5 K. 35°C) | L/min | 71,6 | |
| Buitenafmeting (breedte) | mm | 1.500 | |
| Buitenafmeting (Diepte) | mm | 460 | |
| Wateruitlaat (Warmte) | °C | 20 ~ 75 (4) | |
| Wateruitlaat (Koel) | °C | 5 ~ 20 | |
| Buitenunit | WH-WXG25ME8 | ||
| Verwarming warm klimaat. Seizoensgebonden energie-efficiëntie SCOP (W 35°C / W 55°C) | SCOP | 5,22 / 4,14 | |
| Werkingsbereik - Buitenomgeving (Koel) | °C | +10 ~ +43 | |
| Geluidsvermogen buiten (Warmte) (2) | dB(A) | 59 | |
| Koelmiddel (R290) / CO2 Vergelijking (3) | kg / T | 3,0 / 0,009 | |
| Afstandsbediening met Wi-Fi-adapter | CZ-RTW2TAW1C | ||
| Koelvermogen (A 35°C, W 7°C) in Comfortmodus | kW | 25,00 | |
| EER (A 35°C, W 7°C) in Comfortmodus | EER | 2,86 | |
| Koelvermogen (A 35°C, W 7°C) bij Efficiëntiemodus (standaard) | kW | 15,00 | |
| EER (A 35°C, W 7°C) bij Efficiëntiemodus (standaard) | kW | 3,61 | |
| Koelvermogen (A 35°C, W 18°C) in Comfortmodus | kW | 25,00 | |
| EER (A 35°C, W 18°C) in Comfortmodus | EER | 4,47 | |
| Buiten aanbevolen zekering, voeding (5) | A | 50 | |
| Aanbevolen minimale kabelgrootte buiten, toevoer (5) | mm² | 5x10 - 5x16 | |
| COP (A +2°C, W 35°C) | 2,80 | ||
| Buitenafmeting (Hoogte) | mm | 1.645 | |
| Nettogewicht buiten | kg | 240 | |
| Verwarmingscapaciteit (A +7°C, W 35°C) | kW | 25,00 | |
| COP (A +7°C, W 35°C) | 4,50 | ||
| Verwarmingscapaciteit (A +2°C, W 35°C) | kW | 25,00 | |
| Verwarmingscapaciteit (A -7°C, W 35°C) | kW | 25,00 | |
| COP (A -7°C, W 35°C) | 2,36 | ||
| Verwarmingscapaciteit (A +7°C, W 55°C) | kW | 25,00 | |
| COP (A +7°C, W 55°C) | 3,00 | ||
| Verwarmingscapaciteit (A +2°C, W 55°C) | kW | 25,00 | |
| COP (A +2°C, W 55°C) | 1,97 | ||
| Verwarmingscapaciteit (A -7°C, W 55°C) | kW | 25,00 | |
| COP (A -7°C, W 55°C) | 1,80 | ||
| Gemiddeld verwarmingsklimaat. Seizoensgebonden energie-efficiëntie η (W 35°C / W 55°C) | ηs % | 167 / 140 | |
| Verwarming gemiddeld klimaat. Seizoensgebonden energie-efficiëntie SCOP (W 35°C / W 55°C) | SCOP | 4,25 / 3,57 | |
| Verwarming gemiddeld klimaat. Energieklasse (W 35°C / W 55°C) (1) | A+++ to D | A++/A++ | |
| Verwarming warm klimaat. Seizoensgebonden energie-efficiëntie η (W 35°C / W 55°C) | ηs % | 206 / 163 | |
(1) Schaal van A+++ tot D.
(2) Geluidsvermogensniveau in overeenstemming met EN12102 onder omstandigheden van EN14825 (deellast).
(3) WH-WXG modellen zijn hermetisch afgesloten.
(4) Controleer de plaatselijke voorschriften.
* EER en COP berekening is gebaseerd op EN 14511.