Latest News
- Celebrate 20 Years of Cleaner Air with Panasonic’s nanoe™ Technology 25/04/2024 In today’s health-conscious world, we are becoming increasingly concerned with the way we exercise... Read more
- Panasonic drives towards Net-Zero 19/04/2024 Panasonic is applying sustainable solutions beyond the operation of its products through various col... Read more
- Green Living: Couple Embrace Sustainability with Panasonic R290 Heat Pump Installation 19/04/2024 An environmentally conscious couple turned to expert installer in renewables, Plug Me In, to retrofi... Read more
- Double WIN at National ACR & Heat Pump Awards 2024 28/03/2024 We are delighted to have won two awards at the prestigious National ACR & Heat Pump Awards 2024 in M... Read more
- Panasonic to Showcase Seamless Building Sustainability at Retrofit 24 25/03/2024 Panasonic partners with The Building Centre, London, to showcase its new sustainable and highly effi... Read more
- Elevating Comfort and Efficiency: Panasonic’s Next-Generation Commercial Heating & Cooling Solutions 14/03/2024 Panasonic Heating & Cooling Solutions is committed to providing commercial applications with the hig... Read more
- More Panasonic News
Panasonic Launches a New Switchover Control System for Commercial Air Conditioning Units
26/11/2014
Panasonic has developed a new interface which provides redundancy monitoring and control for PACi and ECOi indoor units. The PAW-PACR3 interface, which is particularly suitable for server rooms, guarantees complete product peace of mind and system maintenance confidence.
It is vital to have an air conditioning unit in server rooms due to the amount of heat generated by computers. If the temperature unexpectedly increases, an increased cooling capacity is required to prevent the computers from failing. With this in mind, Panasonic has introduced the PAW-PACR3 interface which allows up to three PACi or ECOi systems to work together to ensure the room always remains at an optimum temperature.
“When cooling is required 24/7, the operation and reliability of the air conditioning unit is of extreme importance” explains Marc Diaz, UK Country Manager of Panasonic Heating and Cooling. “This change-over system ensures a constant temperature is achieved. It also provides the end-user with the confidence that the units have a long life-span.”
By installing a PAW-T10 connector to each PACi or ECOi indoor unit, the PAW-PACR3 interface provides a backup and rotation operation system. Ideal for 24-hours-a-day, 7-days-a-week operation, the second and third unit can be set up to rotate. This alternating system provides exceptional reliability and an optimum product life cycle for the air conditioning units.
If there is an unexpected temperature rise the second standby unit is activated automatically to achieve room temperature. An optional alarm (internal or external) can be activated to warn of this temperature increase. Once demand has reduced the second unit will return to standby.
The system is also capable of providing back-up control. Should a unit fail; the system will automatically switch operation to another unit. This ensures that there is not a loss of cooling, therefore preventing the possible overheating and failure of critical equipment and data.
The benefits of the PAW-PACR3 display include:
• Ability to select next unit manually
• Possibility to reset operation
• Operation status of the two or three units
• Operation status output
• Alarm LED and alarm output
• Temperature limit can be set
• Room temperature is displayed
• Time counter displayed