PACi NX Series Elite wall-mounted Inverter+ - R32

The wall-mounted units with stylish matt colour can be offered for many applications such as studios, gyms, high ceiling areas and even computer server rooms.

The compact design and flat face ensure discreet installation, even in a small space.

The next generation of commercial air conditioners is here

Specifications

See all
PACi NX Series Elite wall-mounted Inverter+ - R32 SINGLE PHASE THREE PHASE
3.6 kW 5.0 kW 6.0 kW 7.1 kW 10.0 kW 7.1 kW 10.0 kW
Kit KIT-36PK3ZH5 KIT-50PK3ZH5 KIT-60PK3ZH5 KIT-71PK3ZH5 KIT-100PK3ZH5 KIT-71PK3ZH8 KIT-100PK3ZH8
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
Cooling capacity (Nominal) kW 3,6 5,0 6,1 7,1 9,5 7,1 9,5
Cooling capacity (Min) kW 1,2 1,2 1,2 2,2 3,1 2,2 3,1
Cooling capacity (Max) kW 4,0 5,6 7,1 9,0 10,5 9,0 10,5
EER (Nominal) (1) W/W 4,93 4,24 3,86 3,50 3,26 3,50 3,26
EER (Min) (1) W/W 5,45 5,45 5,45 5,79 5,34
EER (Max) (1) W/W 4,49 3,61 3,02 2,69 3,09
SEER (2) 8,4 A++ 8,0 A++ 7,2 A++ 6,8 A++ 6,4 A++ 6,7 A++ 6,3 A++
Pdesign (cooling) kW 3,6 5,0 6,1 7,1 9,5 7,1 9,5
Input power cooling (Nominal) kW 0,73 1,18 1,58 2,03 2,91 2,03 2,91
Input power cooling (Min) kW 0,22 0,22 0,22 0,38 0,58
Input power cooling (Max) kW 8,90 1,55 2,35 3,35 3,40
Annual energy consumption cooling (3) kWh/a 150 219 297 365 520 370 526
Heating capacity (Nominal) kW 4,0 5,6 7,0 8,0 9,5 8,0 9,5
Heating capacity (Min) kW 1,2 1,2 1,2 2,0 3,1 2,0 3,1
Heating capacity (Max) kW 5,0 6,5 8,0 9,0 11,5 9,0 11,5
COP (Nominal) (1) W/W 4,82 4,15 4,19 4,00 3,97 4,00 3,97
COP (Min) (1) W/W 5,45 5,45 5,45 5,56 5,54
COP (Max) (1) W/W 4,17 3,55 3,40 3,16 3,43
SCOP (2) 4,9 A++ 4,7 A++ 4,8 A++ 4,7 A++ 4,1 A+ 4,7 A++ 4,1 A+
Pdesign at -10°C kW 3,6 4,5 4,6 5,2 8,0 5,2 8,0
Input power heating (Nominal) kW 0,83 1,35 1,67 2,00 2,39 2,00 2,39
Input power heating (Min) kW 0,22 0,22 0,22 0,36 0,56
Input power heating (Max) kW 1,20 1,83 2,35 2,85 3,35
Annual energy consumption heating (3) kWh/a 1.029 1.341 1.342 1.549 2.732 1.549 2.732
Indoor unit S-3650PK3E S-3650PK3E S-6010PK3E S-6010PK3E S-6010PK3E S-6010PK3E S-6010PK3E
Indoor air flow (Hi) m³/min 13,0 16,0 20,0 20,0 22,0 20,0 22,0
Indoor air flow (Med) m³/min 11,0 13,5 17,5 17,5 18,5 17,5 18,5
Indoor air flow (Lo) m³/min 9,0 11,0 14,5 14,5 15,0 14,5 15,0
Moisture removal volume L/h 0,9 1,8 2,0 3,0 4,8 3,0 4,8
Indoor sound pressure (Med) (4) dB(A) 31 36 44 44 45 44 45
Indoor sound pressure (Lo) (4) dB(A) 27 32 40 40 41 40 41
Indoor sound power (Hi) dB(A) 51 56 63 63 65 63 65
Indoor sound power (Med) dB(A) 47 52 60 60 61 60 61
Indoor sound power (Lo) dB(A) 43 48 56 56 57 56 57
Indoor dimension (Height) mm 302 302 302 302 302 302 302
Indoor dimension (Width) mm 1.120 1.120 1.120 1.120 1.120 1.120 1.120
Indoor dimension (Depth) mm 236 236 236 236 236 236 236
Indoor net weight kg 13 13 14 14 14 14 14
nanoe X Generator Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2
Outdoor unit U-36PZH3E5 U-50PZH3E5 U-60PZH3E5 U-71PZH3E5 U-100PZH3E5 U-71PZH3E8 U-100PZH3E8
Outdoor power source V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 3,60 5,60 7,40 10,0 14,40 3,40 4,85
Current in cooling (1p 230V / 3p 400) A 3,45 5,35 7,10 9,60 13,80 3,25 4,60
Current in cooling (1p 240V / 3p 415) A 3,30 5,10 6,80 9,20 13,20 3,15 4,40
Current in heating (1p 220V / 3p 380) A 4,05 6,40 7,75 9,65 11,70 3,30 4,00
Current in heating (1p 230V / 3p 400) A 3,90 6,10 7,40 9,35 11,30 3,15 3,80
Current in heating (1p 240V / 3p 415) A ,3,70 5,85 7,10 8,95 10,80 3,05 3,60
Outdoor air flow (Cool) m³/min 34,1 42,0 42,0 61,0 118,0 61,0 118,0
Outdoor air flow (Heat) m³/min 36,4 42,0 42,0 60,0 108,0 60,0 108,0
Outdoor sound pressure (Cool -Hi) dB(A) 43 46 47 48 52 48 52
Outdoor sound pressure (Heat -Hi) dB(A) 44 48 50 50 52 50 52
Outdoor sound power (Cool -Hi) dB(A) 62 64 65 65 69 65 69
Outdoor sound power (Heat -Hi) dB(A) 64 67 69 67 69 67 69
Outdoor dimension (Height) mm 695 695 695 996 1.416 996 1.416
Outdoor dimension (Width) mm 875 875 875 940 940 940 940
Outdoor dimension (Depth) mm 320 320 320 340 340 340 340
Outdoor net weight kg 42 42 43 65 98 65 98
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) (5) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) 1/2 (12,70) (6) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 3 ~ 40 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 85 5 ~ 50 5 ~ 85
Elevation difference (in/out) (7) m 15 / 30 (8) 15 / 30 (8) 15 / 30 (8) 15 / 30 (8) 15 / 30 (8) 15 / 30 (8) 15 / 30 (8)
Pipe length for additional gas m 30 30 30 30 30 30 30
Additional gas amount g/m 15 15 15 45 45 45 45
Refrigerant (R32) / CO2 Eq. kg / T 1,13 / 0,76 1,13 / 0,76 1,15 / 0,78 1,95 / 1,32 3,05 / 2,06 1,95 / 1,32 3,05 / 2,06
Operating range (Cool - Min) °C -15 -15 -15 -15 -20 -15 -20
Operating range (Cool - Max) °C +46 +46 +46 +48 +48 (9) +48 +48 (9)
Operating range (Heat - Min) °C -20 -20 -20 -20 -20 -20 -20
Operating range (Heat - Max) °C +24 +24 +24 +24 +24 +24 +24
1) EER and COP calculation is based in accordance to EN14511.
2) For models below 12kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12kW, the ηs,c / ηs,h values is calculated based on EN 14825.
3) Factory setting.
4) The sound pressure of the units shows the value measured of the position 1m in front of the main body and 1m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
5) Connect the liquid socket tube (Ø6,35-Ø9,52) to the liquid tubing side indoor unit.
6) Connect the gas socket tube (Ø12,70-Ø15,88) to the gas tubing side indoor unit.
7) Outdoor unit located lower / outdoor unit located higher.
8) Pipe length up to 30m.
* Recommended fuse for the indoor 3A.
** Above values are in the case of nanoe™ X OFF.