Stropna jedinica PACi Standard • R32

Ova linija proizvoda za stropnu ugradnju ima istosmjerni motor ventilatora za veću učinkovitost i smanjene razine buke.

Sve su jedinice iste visine i dubine kako bi se postigao ujednačeni izgled pri mješovitoj ugradnji. Omogućeno je ubacivanje svježeg zraka radi poboljšanja kvalitete zraka.

Specifikacije

Prikaži sve
Stropna jedinica PACi Standard • R32
12.5 kW
Kit KIT-125PT2Z5
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 12,5
Cooling capacity (Min) kW 3,2
Cooling capacity (Max) kW 13,5
EER (Nominal) (1) W/W 3,32
EER (Min) (1) W/W 5,33
EER (Max) (1) W/W 2,77
SEER (2) 5,8
Pdesign (cooling) kW 12,5
Input power cooling (Nominal) kW 3,76
Annual energy consumption cooling (3) kWh/a 1300
Input power cooling (Min) kW 0,60
Input power cooling (Max) kW 4,88
Annual energy consumption cooling (3) kWh/a 1300
Heating capacity (Nominal) kW 12,5
Heating capacity (Min) kW 3,3
Heating capacity (Max) kW 15,0
COP (Nominal) (1) W/W 3,89
COP (Min) (1) W/W 4,52
COP (Max) (1) W/W 3,41
SCOP (2) 3,8
Pdesign at -10°C kW 12,5
Input power heating (Nominal) kW 3,21
Input power heating (Min) kW 0,73
Input power heating (Max) kW 4,40
Annual energy consumption heating (3) kWh/a 4669
Indoor unit S-125PT2E5B
Indoor air flow (Hi) m³/min 34,0
Indoor air flow (Med) m³/min 28,0
Indoor air flow (Lo) m³/min 24,0
Moisture removal volume L/h 7,9
Indoor sound pressure (Med) (4) dB(A) 40
Indoor sound pressure (Lo) (4) dB(A) 36
Indoor sound power (Hi) dB(A) 64
Indoor sound power (Med) dB(A) 58
Indoor sound power (Lo) dB(A) 54
Indoor dimension (Height) mm 235
Indoor dimension (Width) mm 1590
Indoor dimension (Depth) mm 690
Indoor net weight kg 40
Outdoor unit U-125PZ2E5
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 17,60
Current in cooling (1p 230V / 3p 400) A 16,90
Current in cooling (1p 240V / 3p 415) A 16,20
Current in heating (1p 220V / 3p 380) A 15,00
Current in heating (1p 230V / 3p 400) A 14,30
Current in heating (1p 240V / 3p 415) A 13,70
Outdoor air flow (Cool) m³/min 86
Outdoor air flow (Heat) m³/min 78
Outdoor sound pressure (Cool -Hi) dB(A) 55
Outdoor sound pressure (Heat -Hi) dB(A) 55
Outdoor sound power (Cool -Hi) dB(A) 73
Outdoor sound power (Heat -Hi) dB(A) 73
Outdoor dimension (Height) mm 996
Outdoor dimension (Width) mm 980
Outdoor dimension (Depth) mm 370
Outdoor net weight kg 94
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 50
Elevation difference (in/out) (5) m 30
Pipe length for additional gas m 30
Additional gas amount g/m 45
Refrigerant (R32) / CO2 Eq. kg / T 2,98 / 2,0115
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C 43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C 24

(1) Vrijednosti EER i COP izračunate su u skladu s normom EN14511.
(2) Skala energetske oznake od A+++ do D. Za modele ispod 12 kW vrijednosti SEER i SCOP izračunate su na temelju vrijednosti odredbe EU/626/2011. Za modele iznad 12 kW vrijednosti SEER i SCOP izračunate su na temelju vrijednosti odredbe EU/2281/2016.
(3) Godišnja potrošnja energije izračunata je u skladu s odredbom EU/626/2011.
(4) Zvučni tlak jedinica prikazuje vrijednost izmjerenu na položaju 1 metar ispred glavnog tijela i 1 metar ispod jedinice. Zvučni tlak mjeren je u skladu sa specifikacijom Eurovent 6/C/006-97.
(5) Prilikom ugradnje vanjske jedinice na položaj viši od unutarnje jedinice.
* Preporučeni osigurač za unutarnju jedinicu 3 A.

Dodatni proizvodi