Stropna jedinica PACi Elite • R32

Jedinice za stropnu ugradnju pružaju velik i širok raspon raspodjele zraka, što je dobro za velike prostorije. Visina i dubina jedinica svih kapaciteta jednaka je kako bi se postigao ujednačeni izgled pri mješovitoj ugradnji.

Specifikacije

Prikaži sve
Stropna jedinica PACi Elite • R32
7.1 kW
Kit KIT-71PT2ZH8
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 7,1
Cooling capacity (Min) kW 2,2
Cooling capacity (Max) kW 9,0
EER (Nominal) (1) W/W 3,78
SEER (2) 6,6 A++
Pdesign (cooling) kW 7,1
Input power cooling (Nominal) kW 1,88
Annual energy consumption cooling (3) kWh/a 375
Annual energy consumption cooling (3) kWh/a 375
Heating capacity (Nominal) kW 8,0
Heating capacity (Min) kW 2,0
Heating capacity (Max) kW 9,0
COP (Nominal) (1) W/W 4,15
SCOP (2) 4,6 A++
Pdesign at -10°C kW 5,2
Input power heating (Nominal) kW 1,93
Annual energy consumption heating (3) kWh/a 1583
Indoor unit S-71PT2E5B
Indoor air flow (Hi) m³/min 21,0
Indoor air flow (Med) m³/min 18,0
Indoor air flow (Lo) m³/min 15,5
Indoor sound pressure (Med) (4) dB(A) 35
Indoor sound pressure (Lo) (4) dB(A) 31
Indoor dimension (Height) mm 235
Indoor dimension (Width) mm 1275
Indoor dimension (Depth) mm 690
Indoor net weight kg 33
Outdoor unit U-71PZH2E8
Outdoor power source V 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 2,95
Current in cooling (1p 230V / 3p 400) A 2,85
Current in cooling (1p 240V / 3p 415) A 2,75
Current in heating (1p 220V / 3p 380) A 3,00
Current in heating (1p 230V / 3p 400) A 2,90
Current in heating (1p 240V / 3p 415) A 2,80
Outdoor air flow (Cool) m³/min 61
Outdoor air flow (Heat) m³/min 60
Outdoor sound pressure (Cool -Hi) dB(A) 48
Outdoor sound pressure (Heat -Hi) dB(A) 50
Outdoor sound power (Cool -Hi) dB(A) 65
Outdoor sound power (Heat -Hi) dB(A) 67
Outdoor dimension (Height) mm 996
Outdoor dimension (Width) mm 940
Outdoor dimension (Depth) mm 340
Outdoor net weight kg 68
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 50
Elevation difference (in/out) (5) m 30
Pipe length for additional gas m 30
Additional gas amount g/m 45
Refrigerant (R32) / CO2 Eq. kg / T 1,95 / 1,316
Operating range (Cool - Min) °C -15
Operating range (Cool - Max) °C 46
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C 24

(1) Vrijednosti EER i COP izračunate su u skladu s normom EN14511.
(2) Skala energetske oznake od A+++ do D. Za modele ispod 12 kW vrijednosti SEER i SCOP izračunate su na temelju vrijednosti odredbe EU/626/2011. Za modele iznad 12 kW vrijednosti SEER i SCOP izračunate su na temelju vrijednosti odredbe EU/2281/2016.
(3) Godišnja potrošnja energije izračunata je u skladu s odredbom EU/626/2011.
(4) Zvučni tlak jedinica prikazuje vrijednost izmjerenu na položaju 1 metar ispred glavnog tijela i 1 metar ispod jedinice. Zvučni tlak mjeren je u skladu sa specifikacijom Eurovent 6/C/006-97.
(5) Prilikom ugradnje vanjske jedinice na položaj viši od unutarnje jedinice.
(6) Za modele 100 ~ 140PZH2E5(8) moguće je podesiti na najnižu temperaturu od -20 °C u računalnim prostorijama s dužinom cijevi od 30 m ili manje.
* Preporučeni osigurač za unutarnju jedinicu 3 A.

Dodatni proizvodi