PACi Standard četverosmjerni sustav 90 x 90 • R32

PACi velikog kapaciteta. Pouzdana snaga i visoka učinkovitost.

Zahvaljujući naprednom dizajnu i tehnologiji poput visokoučinkovitog turboventilatora koji je učinkovitiji i tiši, pročistača zraka nanoe™ X, Panasonicova četverosmjerna 90 x 90 kaseta U2 najbolja je u svojoj klasi u pogledu uštede energije, postizanja svježeg zraka i udobnosti.

Ravnoteža prirode u zatvorenom prostoru

Specifikacije

Prikaži sve
PACi Standard četverosmjerni sustav 90 x 90 • R32 JEDNOFAZNO TROFAZNO
6.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kW 10.0 kW 12.5 kW 14.0 kW
Kit KIT-60PU2Z5 KIT-71PU2Z5 KIT-100PU2Z5 KIT-125PU2Z5 KIT-140PU2Z5 KIT-100PU2Z8 KIT-125PU2Z8 KIT-140PU2Z8
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
EER (Min) (1) W/W 5,36 5,33 5,32 5,36 5,33 5,32
EER (Max) (1) W/W 2,88 2,81 2,73 2,88 2,81 2,73
Annual energy consumption cooling (3) kWh/a 276 327 515 521
Annual energy consumption cooling (3) kWh/a 276 327 515 521
COP (Min) (1) W/W 3,59 3,57 3,33 3,59 3,57 3,33
COP (Max) (1) W/W 5,36 5,50 5,48 5,36 5,50 5,48
Annual energy consumption heating (3) kWh/a 1787 1787 3182 3182
Indoor air flow (Hi) m³/min 21,0 22,0 36,0 37,0 38,0 36,0 37,0 38,0
Indoor air flow (Med) m³/min 16,0 16,0 26,0 27,0 29,0 26,0 27,0 29,0
Indoor air flow (Lo) m³/min 13,0 13,0 18,0 19,0 20,0 18,0 19,0 20,0
Moisture removal volume L/h 1,7 2,5 2,7 4,8 6,0 2,7 4,8 6,0
Indoor sound pressure (Med) (4) dB(A) 31 31 38 39 40 38 39 40
Indoor sound pressure (Lo) (4) dB(A) 28 28 32 33 34 32 33 34
Indoor sound power (Hi) dB(A) 51 52 60 61 62 60 61 62
Indoor sound power (Med) dB(A) 46 46 53 54 55 53 54 55
Indoor sound power (Lo) dB(A) 43 43 47 48 49 47 48 49
nanoe X Generator Mark 1 Mark 1 Mark 1 Mark 1 Mark 1 Mark 1 Mark 1 Mark 1
Outdoor power source V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 7,40 9,95 12,10 16,30 20,40 4,10 5,45 6,85
Current in cooling (1p 230V / 3p 400) A 7,05 9,50 11,50 15,60 19,50 3,90 5,20 6,50
Current in cooling (1p 240V / 3p 415) A 6,75 9,10 11,10 15,00 18,70 3,75 5,00 6,25
Current in heating (1p 220V / 3p 380) A 6,25 8,05 9,25 13,10 15,60 3,15 4,40 5,25
Current in heating (1p 230V / 3p 400) A 5,95 7,70 8,85 12,60 15,00 3,00 4,15 4,95
Current in heating (1p 240V / 3p 415) A 5,70 7,35 8,50 12,00 14,30 2,90 4,00 4,80
Outdoor air flow (Cool) m³/min 40 50 76 86 89 76 86 89
Outdoor air flow (Heat) m³/min 45 45 70 78 83 70 78 83
Outdoor sound pressure (Cool -Hi) dB(A) 46 49 52 55 56 52 55 56
Outdoor sound pressure (Heat -Hi) dB(A) 48 49 52 55 56 52 55 56
Outdoor sound power (Cool -Hi) dB(A) 65 69 70 73 74 70 73 74
Outdoor sound power (Heat -Hi) dB(A) 68 69 70 73 74 70 73 74
Outdoor dimension (Height) mm 695 695 996 996 996 996 996 996
Outdoor dimension (Width) mm 875 875 980 980 980 980 980 980
Outdoor dimension (Depth) mm 320 320 370 370 370 370 370 370
Pipe length range m 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 50 5 ~ 50 5 ~ 50 5 ~ 50 5 ~ 50
Elevation difference (in/out) (5) m 30 30 30 30 30 30 30 30

(1) Vrijednosti EER i COP izračunate su u skladu s normom EN14511.
(2) Skala energetske oznake od A+++ do D. Za modele ispod 12 kW vrijednosti SEER i SCOP izračunate su na temelju vrijednosti odredbe EU/626/2011. Za modele iznad 12 kW vrijednosti SEER i SCOP izračunate su na temelju vrijednosti odredbe EU/2281/2016.
(3) Godišnja potrošnja energije izračunata je u skladu s odredbom EU/626/2011.
(4) Zvučni tlak jedinica prikazuje vrijednost izmjerenu na položaju 1,5 m ispod jedinice. Zvučni tlak mjeren je u skladu sa specifikacijom Eurovent 6/C/006-97.
(5) Prilikom ugradnje vanjske jedinice na položaj viši od unutarnje jedinice.
* Preporučeni osigurač za unutarnju jedinicu 3 A.