„PACi Standard“ keturkryptis 90 x 90 • R32
10.0kW
KIT-100PU2Z8 (S-100PU2E5B + U-100PZ2E8)
Didelės galios „PACi“. Užtikrinta galia ir didelis efektyvumas.
- Didelio našumo turboventiliatorius, šilumokaičio srauto sistema
- „nanoe™ X“, pagerinanti vidaus oro kokybę
- „Econavi“: išmanusis jutiklis energijos eikvojimui mažinti
- Paprasta paramos priemonė, programėlė „Datanavi“ su nuotoliniu valdikliu (CZ-RTC5B)
- Mažesnis triukšmas lėtai veikiant ventiliatoriui
- Lengvasvoris, paprastas vamzdynas
- Su drenažiniu siurbliu
Gamtos pusiausvyros užtikrinimas patalpose
Specifikacijos
| „PACi Standard“ keturkryptis 90 x 90 • R32 | |||
|---|---|---|---|
| 10.0 kW | |||
| Kit | KIT-100PU2Z8 | ||
| Remote controller | CZ-RTC5B | ||
| Cooling capacity (Nominal) | kW | 10,0 | |
| Cooling capacity (Min) | kW | 3,0 | |
| Cooling capacity (Max) | kW | 11,5 | |
| EER (Nominal) (1) | W/W | 3,82 | |
| EER (Min) (1) | W/W | 5,36 | |
| EER (Max) (1) | W/W | 2,88 | |
| SEER (2) | 6,7 A++ | ||
| Pdesign (cooling) | kW | 10,0 | |
| Input power cooling (Nominal) | kW | 2,62 | |
| Annual energy consumption cooling (3) | kWh/a | 521 | |
| Input power cooling (Min) | kW | 0,56 | |
| Input power cooling (Max) | kW | 4,00 | |
| Annual energy consumption cooling (3) | kWh/a | 521 | |
| Heating capacity (Nominal) | kW | 10,0 | |
| Heating capacity (Min) | kW | 3,0 | |
| Heating capacity (Max) | kW | 14,0 | |
| COP (Nominal) (1) | W/W | 4,93 | |
| COP (Min) (1) | W/W | 3,59 | |
| COP (Max) (1) | W/W | 5,36 | |
| SCOP (2) | 4,4 A+ | ||
| Pdesign at -10°C | kW | 10,0 | |
| Input power heating (Nominal) | kW | 2,03 | |
| Input power heating (Min) | kW | 0,56 | |
| Input power heating (Max) | kW | 3,90 | |
| Annual energy consumption heating (3) | kWh/a | 3182 | |
| Indoor unit | S-100PU2E5B | ||
| Indoor air flow (Hi) | m³/min | 36,0 | |
| Indoor air flow (Med) | m³/min | 26,0 | |
| Indoor air flow (Lo) | m³/min | 18,0 | |
| Moisture removal volume | L/h | 2,7 | |
| Indoor sound pressure (Med) (4) | dB(A) | 38 | |
| Indoor sound pressure (Lo) (4) | dB(A) | 32 | |
| Indoor sound power (Hi) | dB(A) | 60 | |
| Indoor sound power (Med) | dB(A) | 53 | |
| Indoor sound power (Lo) | dB(A) | 47 | |
| Indoor dimension (Height) | mm | 319 | |
| Indoor dimension (Width) | mm | 840 | |
| Indoor dimension (Depth) | mm | 840 | |
| Panel dimension (Height) | mm | 33,5 | |
| Panel dimension (Depth) | mm | 950 | |
| Indoor net weight | kg | 25 | |
| Panel net weight | kg | 5 | |
| nanoe X Generator | Mark 1 | ||
| Outdoor unit | U-100PZ2E8 | ||
| Outdoor power source | V | 380 - 400 - 415 | |
| Current in cooling (1p 220V / 3p 380) | A | 4,10 | |
| Current in cooling (1p 230V / 3p 400) | A | 3,90 | |
| Current in cooling (1p 240V / 3p 415) | A | 3,75 | |
| Current in heating (1p 220V / 3p 380) | A | 3,15 | |
| Current in heating (1p 230V / 3p 400) | A | 3,00 | |
| Current in heating (1p 240V / 3p 415) | A | 2,90 | |
| Outdoor air flow (Cool) | m³/min | 76 | |
| Outdoor air flow (Heat) | m³/min | 70 | |
| Outdoor sound pressure (Cool -Hi) | dB(A) | 52 | |
| Outdoor sound pressure (Heat -Hi) | dB(A) | 52 | |
| Outdoor sound power (Cool -Hi) | dB(A) | 70 | |
| Outdoor sound power (Heat -Hi) | dB(A) | 70 | |
| Outdoor dimension (Height) | mm | 996 | |
| Outdoor dimension (Width) | mm | 980 | |
| Outdoor dimension (Depth) | mm | 370 | |
| Outdoor net weight | kg | 90 | |
| Pipe diameter (Liquid) | Inch (mm) | 3/8 (9,52) | |
| Pipe diameter (Gas) | Inch (mm) | 5/8 (15,88) | |
| Pipe length range | m | 5 ~ 50 | |
| Elevation difference (in/out) (5) | m | 30 | |
| Pipe length for additional gas | m | 30 | |
| Additional gas amount | g/m | 45 | |
| Refrigerant (R32) / CO2 Eq. | kg / T | 2,60 / 1,755 | |
| Operating range (Cool - Min) | °C | -10 | |
| Operating range (Cool - Max) | °C | 43 | |
| Operating range (Heat - Min) | °C | -15 | |
| Operating range (Heat - Max) | °C | 24 | |
1) EER ir COP rodikliai apskaičiuoti pagal standartą EN14511.
2) Energijos etiketės skalė nuo A+++ iki D. 12 kW nesiekiančių modelių SEER ir SCOP apskaičiuoti pagal ES/626/2011 nurodytas vertes. 12 kW viršijančių modelių SEER ir SCOP apskaičiuoti pagal ES/2281/2016 nurodytas vertes.
3) Metinės energijos sąnaudos apskaičiuotos pagal ES/626/2011.
4) Blokų garso slėgio vertė buvo išmatuota 1,5 m atstumu nuo bloko apačios. Garso slėgis matuojamas pagal „Eurovent“ specifikaciją 6/C/006-97.
5) Kai lauko blokas įrengiamas aukščiau už vidaus bloką.
* Vidaus blokui rekomenduojamas 3 A saugiklis.