2-Pipe ECOi EX ME2 series high efficiency model combination from 18 to 64HP
50kW
U-10ME2E8 + U-12ME2E8 + U-12ME2E8 + U-16ME2E8 (HEC)
A VRF system delivering energy-saving performance, powerful operation, reliability and comfort surpassing anything previously possible
It represents a true paradigm shift in air conditioning solutions.
- New twin rotary inverter compressor
- High performance at extreme conditions
- Outstanding efficiency and comfort
- Extraordinary partial load and SEER/SCOP
- SEER and SCOP following to EN-14825
- Oil recovery intelligent control
- Top comfort
- Superior flexibility
- Bluefin full line up EX
- Extremely high capacity at -20°C and unique heating capacity at -25°C
- Smooth exhaust flow by new bell-mouth
Specifikacijos
| 2-Pipe ECOi EX ME2 series high efficiency model combination from 18 to 64HP | |||
|---|---|---|---|
| 50 kW | |||
| HP | 50HP | ||
| Outdoor unit | U-10ME2E8 + U-12ME2E8 + U-12ME2E8 + U-16ME2E8 | ||
| Power supply (Voltage) | V | 380 - 400 - 415 | |
| Power supply (Phase) | Three phase | ||
| Power supply (Frequency) | Hz | 50 | |
| Cooling capacity (Nominal) | kW | 140,0 | |
| EER (1) | W/W | 3,87 | |
| Current in cooling (1p 220V / 3p 380) | A | 59,10 | |
| Current in cooling (1p 230V / 3p 400) | A | 56,20 | |
| Current in cooling (1p 240V / 3p 415) | A | 54,20 | |
| Input power cooling | kW | 36,20 | |
| Heating capacity (Nominal) | kW | 155,0 | |
| COP (1) | W/W | 4,65 | |
| Current in heating (1p 220V / 3p 380) | A | 55,00 | |
| Current in heating (1p 230V / 3p 400) | A | 52,20 | |
| Current in heating (1p 240V / 3p 415) | A | 50,40 | |
| Input power heating | W | 33,30 | |
| Starting current | A | 5,00 | |
| External static pressure (Max) | Pa | 80 | |
| Air flow | m³/h | 920 | |
| Sound pressure (Normal mode) | dB(A) | 65,5 | |
| Sound pressure (Silent mode 1) | dB(A) | 62,5 | |
| Sound power (Normal mode) | dB(A) | 86,5 | |
| Dimension (Height) | mm | 1.842 | |
| Dimension (Width) | mm | 4.490 | |
| Dimension (Depth) | mm | 1.000 | |
| Net weight | kg | 1.065 | |
| Piping diameter (Liquid) (2) | Inch (mm) | 3/4 (19,05) / 7/8 (22,22) | |
| Piping diameter (Gas) (2) | Inch (mm) | 1-1/2 (38,10) / 1-5/8 (41,28) | |
| Piping diameter (Balance) (2) | Inch (mm) | 1/4 (6,35) | |
| Refrigerant (R410A) / CO2 Eq. | kg / T | 30,50 / 63,6840 | |
| Maximum allowable indoor / outdoor capacity ratio (3) | % | 50 ~ 130 (200) | |
| Operating range (Cool - Min) | °C | -10 | |
| Operating range (Cool - Max) | °C | +52 | |
| Operating range (Heat - Min) | °C | -25 | |
| Operating range (Heat - Max) | °C | +18 | |
Data is for reference.
1) EER and COP calculation is based in accordance to EN14511.
2) Piping diameter under 90m for ultimate indoor unit / over 90m for ultimate indoor unit (if the longest piping equivalent length exceeds 90m, increase the sizes of the main tubes by 1 rank for gas tubes and liquid tubes).
3) If the following conditions are satisfied, the effective range is above 130% and below 200%: A. Obey the limited number of connectable indoor units. B. The lower limit of operating range for heating outdoor temperature is limited to -10°C WB (standard -25°C WB). C. Simultaneous operation is limited to less than 130% of connectable indoor units.




























