##Delete: PACi Elite Low Static Pressure Hide Away • R410A

The depth of only 250mm provides greater installation flexibility and the unit can be used in more applications. Ideal for sites with narrow ceiling voids.

  • Automatic learning function for the required static pressure on site during commissioning (a standard wired remote controller is required. S-60/71/100/125/140PN1E5B models only)
  • Compact indoor units without loosing static pressure (only 250 mm high)
  • 50 Pa static pressure
  • Easy maintenance and service via external electrical box
  • 3 speed centrifugal fan through wired or Infrared remote controller
  • DC FAN for better efficiency and control
  • Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB. The external device can be controlled by the remote control of the Panasonic indoor unit

Technische Daten

Alles anzeigen
##Delete: PACi Elite Low Static Pressure Hide Away • R410A Einphasig Dreiphasig
36 kW 50 kW 60 kW 71 kW 100 kW 125 kW 140 kW 71 kW 100 kW 125 kW 140 kW
EER (Nominal) (1) W/W 3,75 (4,41 - 3,57) A 3,21 (4,41 - 2,96) A 3,24 (5,00 - 2,78) A 3,30 (4,55 - 2,91) A 3,75 (3,79 - 3,29) A 3,21 (3,30 - 2,92) A 3,01 (3,30 - 2,50) B 3,30 (3,79 - 2,91) A 3,75 (3,79 - 3,29) A 3,21 (3,30 - 2,92) A 3,01 (3,30 - 2,50) A
COP (Nominal) (1) W/W 4,30 (5,17 - 4,00) A 3,81 (5,17 - 3,49) A 3,74 (5,14 - 3,64) A 3,54 (4,00 - 3,08) B 3,80 (4,18 - 3,11) A 3,61 (3,90 - 2,96) A 3,41 (3,90 - 2,95) B 3,54 (3,33 - 3,00) B 3,80 (4,18 - 3,11) A 3,61 (3,90 - 2,96) A 3,41 (3,90 - 2,95) B
Kit KIT-36PN1E5C KIT-50PN1E5C KIT-60PN1E5C KIT-71PN1E5C KIT-100PN1E5C KIT-125PN1E5C KIT-140PN1E5C KIT-71PN1E8C KIT-100PN1E8C KIT-125PN1E8C KIT-140PN1E8C
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
Cooling capacity (Nominal) kW 3,60 5,00 6,00 7,10 10,00 12,50 14,00 7,10 10,00 12,50 14,00
Cooling capacity (Min) kW 1,50 1,50 2,00 2,50 3,30 3,30 3,30 2,50 3,30 3,30 3,30
Cooling capacity (Max) kW 4,00 5,60 7,10 8,00 12,50 14,00 15,50 8,00 12,50 14,00 15,50
EER (Nominal) (1) W/W 3,75 3,21 3,24 3,30 3,75 3,21 3,01 3,30 3,75 3,21 3,01
EER (Min) (1) W/W 4,41 4,41 5,00 4,55 3,79 3,30 3,30 3,79 3,79 3,30 3,30
EER (Max) (1) W/W 3,57 2,96 2,78 2,91 3,29 2,92 2,50 2,91 3,29 2,92 2,50
SEER (2) 4,60 B 4,60 B 5,50 A 5,50 A 5,90 A+ 5,44 5,27 5,10 A 5,60 A+ 5,44 5,27
Pdesign (cooling) kW 3,60 5,00 6,00 7,10 10,00 12,50 14,00 7,10 10,00 12,50 14,00
Input power cooling (Nominal) kW 0,96 1,56 1,85 2,15 2,67 3,89 4,65 2,15 2,67 3,89 4,65
Input power cooling (Min) kW 0,34 0,34 0,40 0,55 0,87 1,00 1,00 0,66 0,87 1,00 1,00
Input power cooling (Max) kW 1,12 1,89 2,55 2,75 3,80 4,80 6,20 2,75 3,80 4,80 6,20
Annual energy consumption cooling (3) kWh/a 274 380 382 452 583 487 621
Heating capacity (Nominal) kW 4,00 5,60 7,00 8,00 11,20 14,00 16,00 8,00 11,20 14,00 16,00
Heating capacity (Min) kW 1,50 1,50 1,80 2,00 4,10 4,10 4,10 2,00 4,10 4,10 4,10
Heating capacity (Max) kW 5,00 6,50 8,00 9,00 14,00 16,00 18,00 9,00 14,00 16,00 18,00
Heating capacity at -7°C (2) kW 7,52 12,04 13,48 14,24 7,52 12,04 13,48 14,24
Heating capacity at -15°C (2) kW
COP (Nominal) (1) W/W 4,30 3,81 3,74 3,54 3,80 3,61 3,41 3,54 3,80 3,61 3,41
COP (Min) (1) W/W 5,17 5,17 5,14 4,00 4,18 3,90 3,90 3,33 4,18 3,90 3,90
COP (Max) (1) W/W 4,00 3,49 3,64 3,08 3,11 2,96 2,95 3,00 3,11 2,96 2,95
SCOP (2) 3,80 A 3,80 A 3,80 A 3,80 A 3,90 A 3,66 3,58 3,80 A 3,80 A 3,66 3,58
Pdesign at -10°C kW 3,60 3,80 5,60 6,20 10,00 12,50 14,00 6,20 10,00 12,50 14,00
Input power heating (Nominal) kW 0,93 1,47 1,87 2,26 2,95 3,88 4,69 2,26 2,95 3,88 4,69
Input power heating (Min) kW 0,29 0,29 0,35 0,50 0,98 1,05 1,05 0,60 0,98 1,05 1,05
Input power heating (Max) kW 1,25 1,86 2,20 2,92 4,50 5,40 6,10 3,00 4,50 5,40 6,10
Annual energy consumption heating (3) kWh/a 1326 1478 2061 2458 3590 2284 3684
Indoor unit S-36PN1E5B S-50PN1E5B S-60PN1E5B S-71PN1E5B S-100PN1E5B S-125PN1E5B S-140PN1E5B S-71PN1E5B S-100PN1E5B S-125PN1E5B S-140PN1E5B
External static pressure (Nominal) (5) Pa 25 25 25 25 40 50 50 25 40 50 50
External static pressure (Min) (5) Pa 10 10 10 10 10 10 10 10 10 10 10
External static pressure (Max) (5) Pa 80 80 80 80 80 80 80 80 80 80 80
Indoor air flow (Hi) m³/min 14,00 16,00 22,00 22,00 36,00 38,00 40,00 22,00 36,00 38,00 40,00
Indoor air flow (Med) m³/min 12,00 13,00 20,00 20,00 33,00 35,00 37,00 20,00 33,00 35,00 37,00
Indoor air flow (Lo) m³/min 10,00 11,00 16,00 16,00 26,00 28,00 30,00 16,00 26,00 28,00 30,00
Indoor sound pressure (Hi) (6) dB(A) 40 41 43 43 44 45 46 43 44 45 46
Indoor sound pressure (Med) (6) dB(A) 38 39 41 41 42 43 44 41 42 43 44
Indoor sound pressure (Lo) (6) dB(A) 35 35 36 36 37 38 39 36 37 38 39
Indoor dimension (Height) mm 250 250 250 250 250 250 250 250 250 250 250
Indoor dimension (Width) mm 780 780 1000 1000 1200 1200 1200 1000 1200 1200 1200
Indoor dimension (Depth) mm 650 650 650 650 650 650 650 650 650 650 650
Indoor net weight kg 29 29 32 32 41 41 41 32 41 41 41
Outdoor unit U-36PE2E5A U-50PE2E5A U-60PE2E5A U-71PE1E5A U-100PE1E5A U-125PE1E5A U-140PE1E5A U-71PE1E8A U-100PE1E8A U-125PE1E8A U-140PE1E8A
Outdoor power source V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 20,00 25,00 30,00 16,00 16,00 16,00 16,00 16,00
Current in cooling (1p 230V / 3p 400) A 2,50 4,00 6,00 2,50 2,50 2,50 2,50 2,50
Current in cooling (1p 240V / 3p 415) A 4,35 7,00 8,60 9,70 11,60 17,40 20,50 3,25 3,95 5,80 6,95
Current in heating (1p 220V / 3p 380) A 4,15 6,65 8,30 9,40 11,20 16,90 20,10 3,10 3,75 5,50 6,60
Current in heating (1p 230V / 3p 400) A 3,95 6,35 7,90 9,20 10,90 16,40 19,50 3,00 3,60 5,30 6,35
Current in heating (1p 240V / 3p 415) A 4,10 6,60 8,75 10,20 12,80 17,30 20,60 3,35 4,35 5,80 7,00
Outdoor air flow (Cool) m³/min 4,00 6,30 8,35 9,90 12,50 16,80 20,20 3,20 4,15 5,50 6,65
Outdoor air flow (Heat) m³/min 3,80 6,05 8,00 9,70 12,20 16,30 19,60 3,10 4,00 5,30 6,45
Outdoor sound pressure (Cool -Hi) dB(A) 38 38 38 60 110 130 135 60 110 130 135
Outdoor sound pressure (Heat -Hi) dB(A) 38 41 41 60 95 110 120 60 95 110 120
Outdoor sound power (Cool -Hi) dB(A) 45 46 46 48 52 53 54 48 52 53 54
Outdoor sound power (Heat -Hi) dB(A) 46 48 49 50 52 53 55 50 52 53 55
Outdoor dimension (Height) mm 619 619 619 996 1416 1416 1416 996 1416 1416 1416
Outdoor dimension (Width) mm 799 799 799 940 940 940 940 940 940 940 940
Outdoor dimension (Depth) mm 299 299 299 340 340 340 340 340 340 340 340
Outdoor net weight kg 39 39 40 69 98 98 98 71 98 98 98
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 3 ~ 40 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 75 5 ~ 75 5 ~ 75 5 ~ 50 5 ~ 75 5 ~ 75 5 ~ 75
Elevation difference (in/out) (7) m 30 30 30 30 30 30 30 30 30 30 30
Pipe length for additional gas m 30 30 30 30 30 30 30 30 30 30 30
Additional gas amount g/m 20 20 40 50 50 50 50 50 50 50 50
Refrigerant (R410A) / CO2 Eq. kg / T 1,40 / 2,9232 1,40 / 2,9232 1,95 / 4,0716 2,35 / 4,9068 3,40 / 7,0992 3,40 / 7,0992 3,40 / 7,0992 2,35 / 4,9068 3,40 / 7,0992 3,40 / 7,0992 3,40 / 7,0992
Operating range (Cool - Min) °C -15 -15 -15 -15 -15 -15 -15 -15 -15 -15 -15
Operating range (Cool - Max) °C +46 +46 +46 +46 +46 +46 +46 +46 +46 +46 +46
Operating range (Heat - Min) °C -20 -20 -20 -20 -20 -20 -20 -20 -20 -20 -20
Operating range (Heat - Max) °C +24 +24 +24 +24 +24 +24 +24 +24 +24 +24 +24

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) Heating capacity is calculated including defrost factor correction.
(5) Medium external static pressure setting from factory.
(6) The sound pressure of the units shows the value measured of the position 1,5 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(7) Add 100 mm for piping port.
(8) When installing the outdoor unit at a higher position than the indoor unit. * Recommended fuse for the indoor 3 A.