All in One 185L DHW tank K Series 1 phase · R32

Previous capacity Next capacity

12kW

KIT-ADC12K6E5 (WH-ADC0912K6E5 + WH-UDZ12KE5)

Aquarea High Performance All in One 185L DHW tank K Series 1 phase · R32

A revolution in design, efficiency, connectivity and sustainability.
Aquarea K Series is a ground breaking low-energy system for heating, cooling and domestic hot water production that delivers outstanding performance. This model is ideal for new installations and well-insulated homes.
Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.
A premium white, faithful to the Aquarea spirit underlined by the seamlessly integrated controller which provides a sleek black band across the unit. The All in One model maintains its compactness with its encroachment of only 598 x 600mm, comparable to a household appliance.
The outdoor units, with an Anthracite Grey colour which will dress the entire range, have been completely redesigned with an innovative design that will find its place in all spaces.

Further comfort and peace of mind with Aquarea

Specifications

See all
All in One 185L DHW tank K Series 1 phase · R32
12 kW
Heating capacity (A +7°C, W 35°C) kW 12,10
COP (A +7°C, W 35°C) 4,78
Heating capacity (A +2°C, W 35°C) kW 11,50
COP (A +2°C, W 35°C) 3,44
Heating capacity (A -7°C, W 35°C) kW 10,10
COP (A -7°C, W 35°C) 2,74
Cooling capacity (A 35°C, W 7°C) kW 10,70
EER (A 35°C, W 7°C) 2,68
Pipe length range m 3 ~ 30 (3 ~ 50) (5)
Indoor dimension (Height) mm 1.642
Indoor net weight kg 101 (6kW)
Outdoor dimension (Height) mm 1.340
Outdoor net weight kg 88
Indoor sound pressure (Heat) dB(A) 33
Refrigerant (R32) / CO2 Eq. kg / T 1,6 / 1,080
Indoor dimension (Width) mm 599
Indoor dimension (Depth) mm 602
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (12,7)
Pipe length for additional gas m 10
Additional gas amount g/m 30
Outdoor unit WH-UDZ12KE5
Heating capacity (A +7°C, W 55°C) kW 12,00
COP (A +7°C, W 55°C) 2,96
Heating capacity (A +2°C, W 55°C) kW 9,20
COP (A +2°C, W 55°C) 2,25
Heating capacity (A -7°C, W 55°C) kW 8,40
COP (A -7°C, W 55°C) 1,97
Cooling capacity (A 35°C, W 18°C) kW 10,70
EER (A 35°C, W 18°C) 3,92
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 180 / 130
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,58 / 3,33
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 256 / 171
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,47 / 4,34
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 169 / 127
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,31 / 3,26
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A++
Indoor sound pressure (Cool) dB(A) 33
Water pipe connector Inch R 1¼
A class pump (Number of speeds) Variable speed
Heating water flow (∆T=5 K. 35°C) L/min 34,4
Water volume L 185
Maximum water temperature °C 65
Material inside tank Stainless steel
Tapping profile according EN16147 L
DHW tank ERP average climate efficiency rating (2) A+ to F A+
DHW tank ERP warm climate efficiency rating (2) A+ to F A
DHW tank ERP cold climate efficiency rating (2) A+ to F A
DHW tank ERP average climate η ηwh % 100
DHW tank ERP warm climate η ηwh % 116
DHW tank ERP cold climate η ηwh % 80
Outdoor dimension (Width) mm 900
Outdoor dimension (Depth) mm 320
Elevation difference (in/out) m 20 (30) (5)
Operation range - Outdoor ambient (Heat) °C -25 ~ +35
Operation range - Outdoor ambient (Cool) °C +10 ~ +43
DHW tank ERP average climate COPdHW COPdHW 2,50
DHW tank ERP warm climate COPdHW COPdHW 2,90
DHW tank ERP cold climate COPdHW COPdHW 2,00
Outdoor sound power (Heat) (3) dB(A) 65
Kit 6kW electric heater KIT-ADC12K6E5
Indoor unit 6kW electric heater WH-ADC0912K6E5
Electrical information 6 kW
Electric backup heater kW 6,00
Recommended fuse A 30 / 30
(1) Scale from A+++ to D.
(2) Scale from A+ to F.
(3) Sound power in accordance to 811/2013, 813/2013 and EN12102-1:2017 at +7°C.
(4) Operation range down to -25°C in heating with 3 ~ 40m pipe length range, operation range down to -15°C in heating with 3 ~ 50m pipe length range.
(5) Check local regulations.
* EER and COP calculation is based in accordance to EN14511.
** This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.

What's happening