T-CAP All in One 260l DHW tank K Series 1 phase - 3 phase · R32
12.10kW
KIT-AXC12K6E53 (WH-ADC0912K6E53 + WH-UXZ12KE5) / KIT-AXC12K6E5AN3 (WH-ADC0912K6E5AN3 + WH-UXZ12KE5)
T-CAP All in One 260l DHW tank K Series 1 phase - 3 phase · R32
A revolution in design, efficiency, connectivity and sustainability.Aquarea K Series is a ground breaking low-energy system for heating, cooling and domestic hot water production that delivers outstanding performance.Aquarea T-CAP is the range for retrofit and new builds, keeping rated capacity even at extremely cold ambient.
Now available in a larger All in One version, perfect for homes with high DHW demand. Despite the increased capacity, it maintains a compact footprint of just 599 x 602 mm—similar to a standard appliance.
Further comfort and peace of mind with Aquarea
Specifications
| T-CAP All in One 260l DHW tank K Series 1 phase - 3 phase · R32 | |||
|---|---|---|---|
| 12.10 kW | |||
| Kit 6kW electric heater | KIT-AXC12K6E53 | ||
| Heating capacity (A +7°C, W 35°C) | kW | 12,10 | |
| COP (A +7°C, W 35°C) | 4,84 | ||
| Heating capacity (A +7°C, W 55°C) | kW | 12,10 | |
| COP (A +7°C, W 55°C) | 3,04 | ||
| Heating capacity (A +2°C, W 35°C) | kW | 12,00 | |
| COP (A +2°C, W 35°C) | 3,44 | ||
| Heating capacity (A +2°C, W 55°C) | kW | 12,00 | |
| COP (A +2°C, W 55°C) | 2,29 | ||
| Heating capacity (A -7°C, W 35°C) | kW | 12,00 | |
| COP (A -7°C, W 35°C) | 2,72 | ||
| Heating capacity (A -7°C, W 55°C) | kW | 12,00 | |
| COP (A -7°C, W 55°C) | 2,29 | ||
| Cooling capacity (A 35°C, W 7°C) | kW | 10,70 | |
| EER (A 35°C, W 7°C) | 2,68 | ||
| Cooling capacity (A 35°C, W 18°C) | kW | 10,70 | |
| EER (A 35°C, W 18°C) | 3,92 | ||
| Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 4,96 / 3,57 | |
| Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 195 / 140) | |
| Heating average climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A++ | |
| Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 6,47 / 4,34 | |
| Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 256 / 171) | |
| Heating warm climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A+++ | |
| Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 4,31 / 3,26 | |
| Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 169 / 127) | |
| Heating cold climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A++ / A++ | |
| Indoor unit 6kW electric heater | WH-ADC0912K6E53 | ||
| Indoor sound pressure (Heat) | dB(A) | 33 | |
| Indoor sound pressure (Cool) | dB(A) | 33 | |
| Indoor dimension (Height) | mm | 2 036 | |
| Indoor dimension (Width) | mm | 599 | |
| Indoor dimension (Depth) | mm | 602 | |
| Indoor net weight | kg | 119 | |
| Water pipe connector | Inch | R1¼ | |
| A class pump (Number of speeds) | Variable speed | ||
| A class pump (Input power Max) | W | 145 | |
| Heating water flow (∆T=5 K. 35°C) | L/min | 34,4 | |
| Water volume | L | 260 | |
| Maximum water temperature | °C | 65 | |
| Material inside tank | Stainless steel | ||
| Tapping profile according EN16147 | XL | ||
| DHW tank ERP average climate efficiency rating (2) | A+ to F | A+ | |
| DHW tank ERP warm climate efficiency rating (2) | A+ to F | A+ | |
| DHW tank ERP cold climate efficiency rating (2) | A+ to F | A | |
| DHW tank ERP average climate η | ηwh % | 123 | |
| DHW tank ERP average climate COPdHW | COPdHW | 3,08 | |
| DHW tank ERP warm climate η | ηwh % | 134 | |
| DHW tank ERP warm climate COPdHW | COPdHW | 3,35 | |
| DHW tank ERP cold climate η | ηwh % | 94 | |
| DHW tank ERP cold climate COPdHW | COPdHW | 2,35 | |
| Outdoor unit | WH-UXZ12KE5 | ||
| Outdoor sound power (Heat) (3) | dB(A) | 65 | |
| Outdoor dimension (Height) | mm | 1 340 | |
| Outdoor dimension (Width) | mm | 900 | |
| Outdoor dimension (Depth) | mm | 320 | |
| Outdoor net weight | kg | 88 | |
| Refrigerant (R290) / CO2 Eq. | kg / T | 1,60 | |
| Refrigerant (R32) / CO2 Eq. | kg / T | 1,080 | |
| Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | |
| Pipe diameter (Gas) | Inch (mm) | 1/2 (12,70) | |
| Pipe length range | m | 3 ~ 30 | |
| Elevation difference (in/out) | m | 20 | |
| Pipe length for additional gas | m | 10 | |
| Additional gas amount | g/m | 30 | |
| Operation range - Outdoor ambient (Heat) | °C | -28 ~ +35 | |
| Operation range - Outdoor ambient (Cool) | °C | +10 ~ +43 | |
| Water outlet (Heat) | °C | 20 ~ 60 | |
| Water outlet (Cool) | °C | 5 ~ 20 | |
| Electrical information | WH-ADC0912K6E53 / WH-ADC0912K6E5AN3 | ||
| Electric backup heater | kW | 6,00 | |
| Recommended fuse | A | 30 / 30 | |
| Recommended minimum cable size, supply 1 (5) | mm² | 3x4,0 | |
| Recommended minimum cable size, supply 2 (5) | mm² | 3x4,0 | |
1) Scale from A+++ to D.
2) Scale from A+ to F.
3) Sound power in accordance to 811/2013, 813/2013 and EN 12102-1:2017 at +7 °C.
4) Operation range down to -25 °C in heating with 3 ~ 40 m pipe length range, operation range down to -15 °C in heating with 3 ~ 50 m pipe length range.
5) Check local regulations.
* EER and COP calculation is based in accordance to EN 14511.
** This product is designed to comply with the European drinking water standard (EU) 2020/2184. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.