Aquarea DHW Heat Pumps wall-mounted
100L
P-DHW100AE5
Aquarea DHW Heat Pumps wall-mounted
Using the natural refrigerant R290, Aquarea DHW Heat Pumps achieve the highest A+ energy efficiency class in their category, significantly reducing energy consumption and CO2 emissions compared to electric heaters.
The compact, wall-mounted models are available with 100-litre and 150-litre DHW tank capacities, making them an excellent choice for urban homes and small households.
- High performance with A+ energy efficiency rating
- Significantly lower CO₂ emissions compared to electric water heaters
- Available in 100L and 150L DHW tank capacities
- Wide operating range: from -5°C to +43°C
- Delivers 60°C hot water using only the heat pump
- Reduced maintenance thanks to dry-check magnesium anode
- User-friendly touch control
Specifications
| Aquarea DHW Heat Pumps wall-mounted | |||
|---|---|---|---|
| 100 L | |||
| Reference | P-DHW100AE5 | ||
| Performance according to EN16147 | . | ||
| Reference hot water temperature (Tref) | °C | 55 | |
| Heating up time (A +14°C / W 55°C) | h:m | 5:44 | |
| Heating up time (A +7°C / W 55°C) | h:m | 6:44 | |
| Heating up time (A +2°C / W 55°C) | h:m | 9:53 | |
| Heating up time in BOOST mode (A +7°C / W 10-55°C) | h:m | 2:37 | |
| DHW tank ERP efficiency average | A+ to F | A+ | |
| DHW tank ERP efficiency warm | A+ to F | A++ | |
| DHW tank ERP efficiency cold | A+ to F | A | |
| DHW tank ERP average climate η | ηwh % | 116 | |
| DHW tank ERP average climate COPdHW | COPdHW | 2,80 | |
| DHW tank ERP warm climate η | ηwh % | 133 | |
| DHW tank ERP warm climate COPdHW | COPdHW | 3,20 | |
| DHW tank ERP cold climate η | ηwh % | 92 | |
| DHW tank ERP cold climate COPdHW | COPdHW | 2,20 | |
| Indoor sound power (1) | dB(A) | 46 | |
| Outdoor sound power (1) | dB(A) | 51 | |
| Load profile | M | ||
| Water volume | L | 100 | |
| Water volume of mixed water at 40°C / V40 | L | 128 | |
| Additional coil exchanger connection | — | ||
| Additional coil surface | m² | — | |
| Anticorrosion system | Anode | Magnesium | |
| Anti-legionella cycle | Yes | ||
| Maximum working pressure - storage tank | Mpa (bar) | 0,8 (8) | |
| Dimension (Height) | mm | 1.351 | |
| Dimension (Width) | mm | 520 | |
| Dimension (Depth) | mm | 541 | |
| Empty weight | kg | 56 | |
| Heat pump air intake temperature range | °C | -5 ~ +43 | |
| Maximum water temperature / with heater | °C | 60 / 70 | |
| Refrigerant charge (R290) | kg | 0,15 | |
| Power supply (Voltage) | V | 230 | |
| Power supply (Frequency) | Hz | 50 | |
| Total maximum power consumption | W | 1.726 | |
| Heat pump maximum power consumption | W | 226 | |
| Electric heating element power consumption | W | 1.500 | |
| Air flow (Nominal) | m³/h | 235 | |
| External pressure nominal / maximum | Pa | 42 / 220 | |
| Duct diameter | mm | 125 | |
(1) According to EN12102.