Aquarea DHW Heat Pumps floor-standing
194L
P-DHW200CAE5
Aquarea DHW Heat Pumps floor-standing
Using the natural refrigerant R290, Aquarea DHW Heat Pumps achieve the highest A+ energy efficiency class in their category, significantly reducing energy consumption and CO₂ emissions compared to electric heaters.
The floor standing models are available with 200-litre and 260-litre DHW tank capacities, making them an ideal solution for households with higher hot water demand.
- High performance with A+ energy efficiency rating
- Significantly lower CO₂ emissions compared to electric water heaters
- Available in 200L and 260L DHW tank capacities
- Optional coil version for integration with other heat sources (e.g. PV panels)
- Wide operating range: from -7°C to +43°C
- Delivers 65°C hot water using only the heat pump
- Reduced maintenance thanks to dry-check magnesium anode
- User-friendly touch control
Specifications
| Aquarea DHW Heat Pumps floor-standing | |||
|---|---|---|---|
| 194 L | |||
| Reference | P-DHW200CAE5 | ||
| Performance according to EN16147 | . | ||
| Reference hot water temperature (Tref) | °C | 55 | |
| Heating up time (A +14°C / W 55°C) | h:m | 7:11 | |
| Heating up time (A +7°C / W 55°C) | h:m | 7:38 | |
| Heating up time (A +2°C / W 55°C) | h:m | 11:14 | |
| Heating up time in BOOST mode (A +7°C / W 10-55°C) | h:m | 3:39 | |
| DHW tank ERP efficiency average | A+ to F | A+ | |
| DHW tank ERP efficiency warm | A+ to F | A++ | |
| DHW tank ERP efficiency cold | A+ to F | A | |
| DHW tank ERP average climate η | ηwh % | 140 | |
| DHW tank ERP average climate COPdHW | COPdHW | 3,36 | |
| DHW tank ERP warm climate η | ηwh % | 150 | |
| DHW tank ERP warm climate COPdHW | COPdHW | 3,61 | |
| DHW tank ERP cold climate η | ηwh % | 108 | |
| DHW tank ERP cold climate COPdHW | COPdHW | 2,63 | |
| Indoor sound power (1) | dB(A) | 50 | |
| Outdoor sound power (1) | dB(A) | 56 | |
| Load profile | L | ||
| Water volume | L | 194 | |
| Water volume of mixed water at 40°C / V40 | L | 267 | |
| Additional coil exchanger connection | 1’’M | ||
| Additional coil surface | m² | 1,05 | |
| Anticorrosion system | Anode | Magnesium | |
| Anti-legionella cycle | Yes | ||
| Maximum working pressure - storage tank | Mpa (bar) | 0,8 (8) | |
| Dimension (Height) | mm | 1.621 | |
| Dimension (Width) | mm | 705 | |
| Dimension (Depth) | mm | 694 | |
| Empty weight | kg | 110 | |
| Heat pump air intake temperature range | °C | -7 ~ +43 | |
| Maximum water temperature / with heater | °C | 65 / 75 | |
| Refrigerant charge (R290) | kg | 0,15 | |
| Power supply (Voltage) | V | 230 | |
| Power supply (Frequency) | Hz | 50 | |
| Total maximum power consumption | W | 1.970 | |
| Heat pump maximum power consumption | W | 470 | |
| Electric heating element power consumption | W | 1.500 | |
| Air flow (Nominal) | m³/h | 360 | |
| External pressure nominal / maximum | Pa | 88 / 220 | |
| Duct diameter | mm | 160 | |
(1) According to EN12102.