Hydraulic Split All in One 120l DHW tank L Series 1 phase · R290

9.00kW

WH-ADC0509L3E51 + WH-WDG09LE5

Aquarea High Performance Hydraulic Split All in One 120l DHW tank L Series

A revolution in design, efficiency, connectivity and sustainability. Aquarea L Series is engineered with R290 natural refrigerant (GWP 0,02). It is the ideal for renovations, where a high water outlet temperature is required or homes looking for a high-performance heat pump, to maximise energy savings and minimise CO2 emissions.


Now available in a more compact All in One version, perfect for homes with lower DHW demand, it maintains a footprint of just 599 x 602 mm—similar to a standard appliance.

Further comfort and peace of mind with Aquarea

Specifications

See all
Hydraulic Split All in One 120l DHW tank L Series 1 phase · R290
9.00 kW
Water volume L 30
Outdoor dimension (Depth) mm 430
Outdoor dimension (Width) mm 980
DHW tank ERP cold climate η ηwh % 90
DHW tank ERP warm climate η ηwh % 134
DHW tank ERP average climate η ηwh % 115
Tapping profile according EN16147 M
Material inside tank Stainless steel
Maximum water temperature °C 65
Elevation difference (in/out) m 10
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++/A++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,31/3,33
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 170/130
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++/A+++
Outdoor sound power (Heat) (2) dB(A) 54
Pipe length range maximum m 30
Pipe length range standard m 5
Water pipe connector (outdoor units) Inch 1
Water pipe connector (indoor units) Inch 1
Water pipe connector (shower) Inch ¾
Water pipe connector (room) Inch
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,44/4,50
Indoor unit 3kW electric heater WH-ADC0509L3E51
DHW tank ERP cold climate COPdHW COPdHW 2,26
DHW tank ERP warm climate COPdHW COPdHW 3,35
DHW tank ERP average climate COPdHW COPdHW 2,88
Operation range - outdoor temperature (Cool) °C +10~+43
Operation range - outdoor temperature (Heat) °C -25~+35
Water outlet (Cool) °C 5~20
Water outlet (Heat) °C 20~75
COP (A +7°C, W 35°C) 4,55
Indoor net weight kg 79
Indoor dimension (Height) mm 1.293
EER (A 35°C, W 7°C) 2,82
Cooling capacity (A 35°C, W 7°C) kW 8,20
COP (A -7°C, W 35°C) 2,80
Heating capacity (A -7°C, W 35°C) kW 7,00
COP (A +2°C, W 35°C) 3,41
Heating capacity (A +2°C, W 35°C) kW 7,00
Outdoor dimension (Height) mm 996
Heating capacity (A +7°C, W 35°C) kW 9,00
COP (A +2°C, W 55°C) 2,41
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 255/177
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++/A++
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,84/3,67
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 190/144
EER (A 35°C, W 18°C) 4,19
Cooling capacity (A 35°C, W 18°C) kW 9,00
COP (A -7°C, W 55°C) 2,13
Heating capacity (A -7°C, W 55°C) kW 7,00
Heating capacity (A +2°C, W 55°C) kW 7,00
COP (A +7°C, W 55°C) 3,03
Heating capacity (A +7°C, W 55°C) kW 8,90
Outdoor unit WH-WDG09LE5
Indoor dimension (Depth) mm 602
Indoor dimension (Width) mm 599
Outdoor net weight kg 97

1) Scale from A+++ to D.

2) Scale from A+ to F. 

3) Sound power level in accordance to EN 12102 under conditions of the EN14825 (part load).

4) Check local regulations

* EER and COP calculation is based in accordance to EN 14511.