PACi NX Series Elite wall-mounted - PK4 · R32

PACi NX Series Elite wall-mounted - PK4 · R32

Stylish matt-finish wall-mounted units, ideal for studios, gyms, high ceilings and server rooms.

The next generation of commercial air conditioners is here

Specifications

See all
PACi NX Series Elite wall-mounted - PK4 · R32 SINGLE PHASE THREE PHASE
3.6 kW 5.0 kW 6.0 kW 7.1 kW 10.0 kW 7.1 kW 10.0 kW
Input power heating (Min) kW 0,22 0,22 0,22 0,36 0,58 0,36 0,58
Outdoor dimension (Width) mm 875 875 875 980 980 980 980
Outdoor air flow (Heat) m³/min 36,4 42,0 42,0 66,0 70,0 66,0 70,0
Outdoor air flow (Cool) m³/min 34,1 42,0 42,0 62,0 76,0 62,0 76,0
nanoe X Generator Mark 3 Mark 3 Mark 3 Mark 3 Mark 3 Mark 3 Mark 3
Moisture removal volume L/h 1,0 1,6 1,9 2,4 4,4 2,4 4,4
Input power heating (Max) kW 1,50 2,10 2,35 2,85 3,83 2,85 3,83
Outdoor dimension (Depth) mm 320 320 320 370 370 370 370
COP (Max) (1) W/W 5,45 5,45 5,45 5,56 5,34 5,56 5,34
COP (Min) (1) W/W 3,33 3,10 3,40 3,16 3,00 3,16 3,00
Heating capacity (Max) kW 5,0 6,5 8,0 9,0 11,5 9,0 11,5
Heating capacity (Min) kW 1,2 1,2 1,2 2,0 3,1 2,0 3,1
Input power cooling (Max) kW 0,96 1,85 2,35 3,35 3,40 3,35 3,40
Input power cooling (Min) kW 0,22 0,22 0,22 0,38 0,58 0,38 0,58
EER (Max) (1) W/W 5,45 5,45 5,45 5,79 5,34 5,79 5,34
EER (Min) (1) W/W 4,17 3,03 3,02 2,69 3,09 2,69 3,09
Cooling capacity (Max) kW 4,0 5,6 7,1 9,0 10,5 9,0 10,5
Current in heating (1p 220V / 3p 380) A 4,60 6,60 7,90 9,85 12,10 3,30 4,05
Indoor sound pressure (Lo) (5) dB(A) 30 31 40 40 41 40 41
Indoor sound pressure (Med) (5) dB(A) 36 36 44 44 45 44 45
Indoor sound pressure (Hi) (5) dB(A) 41 41 47 47 49 47 49
Indoor air flow (Lo) m³/min 7,0 12,0 16,5 16,5 17,5 16,5 17,5
Indoor air flow (Med) m³/min 9,5 15,5 19,0 19,0 20,0 19,0 20,0
Indoor air flow (Hi) m³/min 11,5 17,0 21,0 21,0 22,5 21,0 22,5
Indoor sound power (Lo) dB(A) 46 47 56 56 57 56 57
Indoor sound power (Med) dB(A) 52 52 60 60 61 60 61
Current in heating (1p 240V / 3p 415) A 4,20 6,05 7,25 9,05 11,10 3,00 3,70
Current in heating (1p 230V / 3p 400) A 4,40 6,30 7,55 9,40 11,50 3,15 3,85
Cooling capacity (Min) kW 1,2 1,2 1,2 2,2 3,1 2,2 3,1
Current in cooling (1p 240V / 3p 415) A 3,60 5,30 7,00 8,75 12,60 3,00 4,20
Current in cooling (1p 230V / 3p 400) A 3,75 5,55 7,30 9,15 13,20 3,05 4,45
Current in cooling (1p 220V / 3p 380) A 3,90 5,80 7,65 9,55 13,80 3,20 4,65
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
Outdoor sound power (Heat -Hi) dB(A) 64 67 69 67 69 67 69
Outdoor sound power (Cool -Hi) dB(A) 62 64 65 65 69 65 69
Outdoor sound pressure (Heat -Hi) dB(A) 44 48 50 50 52 50 52
Outdoor sound pressure (Cool -Hi) dB(A) 43 46 47 48 52 48 52
Elevation difference (in/out) (8) m 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30
Indoor net weight kg 9 14 14 14 14 14 14
Input power heating (Nominal) kW 0,94 1,39 1,70 1,95 2,44 1,95 2,44
Pdesign at -10°C kW 3,1 4,5 4,6 5,2 8,0 5,2 8,0
SCOP (2) 4,7 A++ 4,6 A++ 4,7 A++ 4,6 A++ 4,1 A+ 4,6 A++ 4,1 A+
Annual energy consumption heating (3) kWh/a 924 1.369 1.370 1.583 2.731 1.583 2.731
Annual energy consumption cooling (3) kWh/a 160 219 301 377 504 377 504
Input power cooling (Nominal) kW 0,79 1,22 1,63 1,89 2,79 1,89 2,79
Pdesign (cooling) kW 3,5 5,0 6,1 7,1 9,5 7,1 9,5
SEER (2) 7,7 A++ 8,0 A++ 7,1 A++ 6,6 A++ 6,6 A++ 6,6 A++ 6,6 A++
Outdoor net weight kg 42 42 43 66 84 66 82
Outdoor dimension (Height) mm 695 695 695 996 996 996 996
Operating range (Cool - Min) °C -15 -15 -15 -15 -20 (9) -15 -20 (9)
Indoor dimension (Height) mm 290 295 295 295 295 295 295
Pipe length range m 3 ~ 40 3 ~ 40 3 ~ 40 5 ~ 60 5 ~ 100 5 ~ 60 5 ~ 100
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) (6) 1/4 (6,35) (6) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Operating range (Heat - Max) °C +24 +24 +24 +24 +24 +24 +24
Operating range (Heat - Min) °C -20 -20 -20 -20 -20 -20 -20
Operating range (Cool - Max) °C +46 +46 +46 +52 +52 +52 +52
Outdoor unit U-36PZH3E5 U-50PZH3E5 U-60PZH3E5 U-71PZH4E5 U-100PZH4E5 U-71PZH4E8 U-100PZH4E8
Indoor unit S-2545PK4E S-5010PK4E S-5010PK4E S-5010PK4E S-5010PK4E S-5010PK4E S-5010PK4E
Kit KIT-36PK4ZH5 KIT-50PK4ZH5 KIT-60PK4ZH5 KIT-71PK4ZH45 KIT-100PK4ZH45 KIT-71PK4ZH48 KIT-100PK4ZH48
Additional gas amount g/m 1,13 / 0,76 1,13 / 0,76 1,15 / 0,78 1,95 / 1,32 2,70 / 1,82 1,95 / 1,32 2,70 / 1,82
Pipe length for additional gas m 30 30 30 30 30 30 30
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) (7) 1/2 (12,70) (7) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Indoor dimension (Depth) mm 214 249 249 249 249 249 249
Indoor dimension (Width) mm 765 1.060 1.060 1.060 1.060 1.060 1.060
Refrigerant (R32) / CO2 Eq. kg / T 15 15 15 30 40 30 40
Indoor sound power (Hi) dB(A) 57 57 63 63 65 63 65
EER (Nominal) (1) W/W 4,43 4,10 3,74 3,76 3,41 3,76 3,41
COP (Nominal) (1) W/W 4,26 4,03 4,12 4,00 3,89 4,00 3,89
Outdoor power source V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415 380 - 400 - 415
Heating capacity (Nominal) kW 4,0 5,6 7,0 7,8 9,5 7,8 9,5
Cooling capacity (Nominal) kW 3,5 5,0 6,1 7,1 9,5 7,1 9,5

1) EER and COP calculation is based in accordance to EN 14511.
2) For models below 12kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12kW, the ηs,c / ηs,h values is calculated based on EN 14825.
3) Factory setting.
4) The value is based on the interpolation.
5) The sound pressure of the units shows the value measured of the position 1m in front of the main body and 1m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
6) Connect the liquid socket tube (Ø6,35-Ø9,52) to the liquid tubing side indoor unit.
7) Connect the gas socket tube (Ø12,70-Ø15,88) to the gas tubing side indoor unit.
8) Outdoor unit located lower / outdoor unit located higher.
9) Pipe length up to 30m.
* Recommended fuse for the indoor 3A.
** Above values are in the case of nanoe™ X OFF.