T-CAP All in One 260l DHW tank K Series 1 phase - 3 phase · R32

T-CAP All in One 260l DHW tank K Series 1 phase - 3 phase · R32 


A revolution in design, efficiency, connectivity and sustainability. Aquarea K Series is a ground breaking low-energy system for heating, cooling and domestic hot water production that delivers outstanding performance. Aquarea T-CAP is the range for retrofit and new builds, keeping rated capacity even at extremely cold ambient.

Now available in a larger All in One version, perfect for homes with high DHW demand. Despite the increased capacity, it maintains a compact footprint of just 599 x 602 mm—similar to a standard appliance.



• A+++ in heating at 35°C and A+ in DHW
• Stainless steel DHW tank with U-Vacua™ insulation panel
• 598 x 600 footprint
• Built-in magnetic water filter
• Rated capacity down to -15°C at 55 ºC water outlet
• Operating range down to -28°C
• Optional Wi-Fi adapter

Further comfort and peace of mind with Aquarea

Specifications

See all
T-CAP All in One 260l DHW tank K Series 1 phase - 3 phase · R32 SINGLE PHASE THREE PHASE
9.00 kW 12.10 kW 9.00 kW 12.10 kW 16.00 kW
Kit 6kW electric heater KIT-AXC09K6E53 KIT-AXC12K6E53
Heating capacity (A +7°C, W 35°C) kW 9,00 12,10 9,00 12,10 16,00
COP (A +7°C, W 35°C) 5,03 4,84 5,03 4,84 4,38
Heating capacity (A +7°C, W 55°C) kW 9,00 12,10 9,00 12,10 16,00
COP (A +7°C, W 55°C) 3,07 3,04 3,07 3,04 2,72
Heating capacity (A +2°C, W 35°C) kW 9,00 12,00 9,00 12,00 16,00
COP (A +2°C, W 35°C) 3,69 3,44 3,69 3,44 3,10
Heating capacity (A +2°C, W 55°C) kW 9,00 12,00 9,00 12,00 16,00
COP (A +2°C, W 55°C) 2,31 2,29 2,31 2,29 2,07
Heating capacity (A -7°C, W 35°C) kW 9,00 12,00 9,00 12,00 16,00
COP (A -7°C, W 35°C) 3,00 2,72 3,00 2,72 2,39
Heating capacity (A -7°C, W 55°C) kW 9,00 12,00 9,00 12,00 16,00
COP (A -7°C, W 55°C) 2,10 2,29 2,10 2,29 1,71
Cooling capacity (A 35°C, W 7°C) kW 8,80 10,70 8,80 10,70 13,40
EER (A 35°C, W 7°C) 3,11 2,68 3,11 2,68 2,64
Cooling capacity (A 35°C, W 18°C) kW 8,80 10,70 8,80 10,70 15,50
EER (A 35°C, W 18°C) 4,63 3,92 4,63 3,92 3,60
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,96 / 3,57 4,96 / 3,57 4,96 / 3,57 4,58 / 3,46 4,46 / 3,31
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 195 / 140) 195 / 140) 195 / 140) 180 / 135) 176 / 129)
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,47 / 4,34 6,47 / 4,34 6,47 / 4,34 6,47 / 4,34 5,88 / 4,09
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 256 / 171) 256 / 171) 256 / 171) 256 / 171) 232 / 160)
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,31 / 3,26 4,31 / 3,26 4,31 / 3,26 4,31 / 3,26 3,83 / 3,20
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 169 / 127) 169 / 127) 169 / 127) 169 / 127) 150 / 125)
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++
Indoor unit 6kW electric heater WH-ADC0912K6E53 WH-ADC0912K6E53
Indoor sound pressure (Heat) dB(A) 33 33 33 33 33
Indoor sound pressure (Cool) dB(A) 33 33 33 33 33
Indoor dimension (Height) mm 2 036 2 036 2 036 2 036 2 036
Indoor dimension (Width) mm 599 599 599 599 599
Indoor dimension (Depth) mm 602 602 602 602 602
Indoor net weight kg 119 119 119 119 120
Water pipe connector Inch R1¼ R1¼ R1¼ R1¼ R1¼
A class pump (Number of speeds) Variable speed Variable speed Variable speed Variable speed Variable speed
A class pump (Input power Max) W 145 145 145 145 145
Heating water flow (∆T=5 K. 35°C) L/min 25,8 34,4 25,8 34,4 45,9
Water volume L 260 260 260 260 260
Maximum water temperature °C 65 65 65 65 65
Material inside tank Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel
Tapping profile according EN16147 XL XL XL XL XL
DHW tank ERP average climate efficiency rating (2) A+ to F A+ A+ A+ A+ A+
DHW tank ERP warm climate efficiency rating (2) A+ to F A+ A+ A+ A+ A+
DHW tank ERP cold climate efficiency rating (2) A+ to F A A A A A
DHW tank ERP average climate η ηwh % 123 123 123 123 98
DHW tank ERP average climate COPdHW COPdHW 3,08 3,08 3,08 3,08 2,45
DHW tank ERP warm climate η ηwh % 134 134 134 134 123
DHW tank ERP warm climate COPdHW COPdHW 3,35 3,35 3,35 3,35 3,08
DHW tank ERP cold climate η ηwh % 94 94 94 94 80
DHW tank ERP cold climate COPdHW COPdHW 2,35 2,35 2,35 2,35 2,00
Outdoor unit WH-UXZ09KE5 WH-UXZ12KE5 WH-UXZ09KE8 WH-UXZ12KE8 WH-UXZ16KE8
Outdoor sound power (Heat) (3) dB(A) 65 65 65 65 65
Outdoor dimension (Height) mm 1 340 1 340 1 340 1 340 1 340
Outdoor dimension (Width) mm 900 900 900 900 900
Outdoor dimension (Depth) mm 320 320 320 320 320
Outdoor net weight kg 88 88 90 90 103
Refrigerant (R290) / CO2 Eq. kg / T 1,60 1,60 1,60 1,60 1,83
Refrigerant (R32) / CO2 Eq. kg / T 1,080 1,080 1,080 1,080 1,235
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) 1/2 (12,70) 1/2 (12,70) 1/2 (12,70)
Pipe length range m 3 ~ 30 3 ~ 30 3 ~ 30 3 ~ 30 3 ~ 30
Elevation difference (in/out) m 20 20 20 20 20
Pipe length for additional gas m 10 10 10 10 10
Additional gas amount g/m 30 30 30 30 30
Operation range - Outdoor ambient (Heat) °C -28 ~ +35 -28 ~ +35 -28 ~ +35 -28 ~ +35 -28 ~ +35
Operation range - Outdoor ambient (Cool) °C +10 ~ +43 +10 ~ +43 +10 ~ +43 +10 ~ +43 +10 ~ +43
Water outlet (Heat) °C 20 ~ 60 20 ~ 60 20 ~ 60 20 ~ 60 20 ~ 60
Water outlet (Cool) °C 5 ~ 20 5 ~ 20 5 ~ 20 5 ~ 20 5 ~ 20
Electrical information WH-ADC0912K6E53 / WH-ADC0912K6E5AN3 WH-ADC0912K6E53 / WH-ADC0912K6E5AN3 WH-ADC0912K9E83 / WH-ADC0912K9E8AN3 WH-ADC0912K9E83 / WH-ADC0912K9E8AN3 WH-ADC16K9E83 / WH-ADC16K9E8AN3
Electric backup heater kW 6,00 6,00 9,00 9,00 9,00
Recommended fuse A 30 / 30 30 / 30 20 / 20 20 / 20 20 / 20
Recommended minimum cable size, supply 1 (5) mm² 3x4,0 3x4,0 5x1,5 5x1,5 5x2,5
Recommended minimum cable size, supply 2 (5) mm² 3x4,0 3x4,0 5x1,5 5x1,5 5x1,5

1) Scale from A+++ to D.

2) Scale from A+ to F.

3) Sound power in accordance to 811/2013, 813/2013 and EN 12102-1:2017 at +7 °C.

4) Operation range down to -25 °C in heating with 3 ~ 40 m pipe length range, operation range down to -15 °C in heating with 3 ~ 50 m pipe length range.

5) Check local regulations.

* EER and COP calculation is based in accordance to EN 14511.

** This product is designed to comply with the European drinking water standard (EU) 2020/2184. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.