3.50 kW. LZ Retro Fit 249 Inverter+ - R32

CS-LZ35TKE + CU-LZ35TKE

Forrige kapasitet Neste kapasitet

LZ - perfekt vid utbyte av äldre värmepump

LZ-modellerna är effektiva och pålitliga även vid utomhustemperaturer så låga som -35 grader. Tack vare den genomtänkta designen är LZ perfekt som utbytespump.

 

Utforsk en ny generasjon varmepumpesystemer

The air conditioning connects with the future

Vi hjelper deg å velge riktig Panasonic-luftvarmepumpe til hjemmet

Spesifikasjoner

Se alle
LZ Retro Fit 249 Inverter+ - R32 Enfaset
3.50 kW
Maximum capacity kW 7,65
Reference CS-LZ35TKE + CU-LZ35TKE
Heating capacity (Nominal) kW 4,20
Heating capacity (Min) kW 0,85
Heating capacity (Max) kW 7,65
COP (1) W/W 4,72 
Heating capacity at -7°C (2) kW 4,60
COP at -7°C (1) W/W 2,35
Heating capacity at -15°C (2) kW 4,35
COP at -15°C (1) W/W 2,25
Heating capacity at -20°C (2) kW 3,70
COP at -20°C (1) W/W 2,03
Heating capacity at -25°C (2) kW 3,10
COP at -25°C (1) W/W 1,83
SCOP (3) 4,90 A++
SCOP tested by 3rd party laboratory DTI
Pdesign at -10°C kW 3,80
Input power heating (Nominal) kW 0,89
Input power heating (Min) kW 0,17
Input power heating (Max) kW 2,30
Annual energy consumption heating (4) kWh/a 1086
Cooling capacity (Nominal) kW 3,50
Cooling capacity (Min) kW 0,85
Cooling capacity (Max) kW 4,00
SEER (3) 7,40 A++
Pdesign (cooling) kW 3,50
Input power cooling (Nominal) kW 0,86
Input power cooling (Min) kW 0,17
Input power cooling (Max) kW 1,08
Annual energy consumption cooling (4) kWh/a 166
Indoor unit CS-LZ35TKE
Indoor power source V 230
Indoor air flow (Heat) m³/min 13,0
Indoor air flow (Cool) m³/min 10,5
Moisture removal volume L/h 2,0
Indoor sound pressure (Heat -Hi) (5) dB(A) 46
Indoor sound pressure (Heat -Lo) (5) dB(A) 30
Indoor sound pressure (Heat -Q-Lo) (5) dB(A) 19
Indoor sound pressure (Cool -Hi) (5) dB(A) 43
Indoor sound pressure (Cool -Lo) (5) dB(A) 28
Indoor sound pressure (Cool -Q-Lo) (5) dB(A) 21
Indoor dimension (Height) mm 249
Indoor dimension (Width) mm 790
Indoor dimension (Depth) mm 355
Indoor net weight kg 11
Outdoor unit CU-LZ35TKE
Outdoor air flow (Heat) m³/min 35,6
Outdoor air flow (Cool) m³/min 34,4
Outdoor sound pressure (Heat -Hi) (5) dB(A) 47
Outdoor sound pressure (Cool -Hi) (5) dB(A) 45
Outdoor dimension (Height) (6) mm 622
Outdoor dimension (Width) (6) mm 824
Outdoor dimension (Depth) (6) mm 299
Outdoor net weight kg 38
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 3/8 (9,52)
Pipe length range m 3 ~ 20
Elevation difference (in/out) (7) m 10
Pipe length for additional gas m 7,5
Additional gas amount g/m 20
Refrigerant (R32) / CO2 Eq. kg / T 1,10 / 0,743
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C +24
Operating range (Cool - Min) °C -15
Operating range (Cool - Max) °C +43
Lowest outdoor temperature tested by 3rd party laboratory (8) °C

(1) COP-beräkningen utförd i enlighet med EN 14511.
(2) Kapacitet av värmepumpen är testad under maximalt effekt och avfrostning.
(3) Energimärkning skala från A+++ till D. * SCOP testat av oberoende testlaboratorium DTI i enlighet med EN 14825:2016. ** A+++ är uträknat från SCOP-test utfört av Teknologisk Institut i Danmark. Testrapporten från Teknologiske institut finns att läsa på: lz25test.panasonic.se.
(4) Den årliga energiförbrukningen är beräknad i enlighet med EU-förordning 626/2011.
(5) Ljudtrycksnivån för inomhusenheten visar det uppmätta värdet från en position 1 m framför huvudenheten och 0,8 meter under enheten. För utomhusenhet 1 m framför och 1 m bakom huvudenheten. Ljudtrycket är uppmätt i enlighet med JIS C 9612. Q-låg: Tyst läge. Låg: Den lägsta inställda fläkthastigheten.
(6) Lägg till 70 mm för röringång.
(7) Vid installation av utomhusenheten i högre läge än inomhusenheten.
(8) Testat av DTI, ett oberoende testlaboratorium, i enlighet med EN 14511:2013, denna temperatur garanteras inte av fabriken.

Case-studier Se alle prosjektene

Godt å vite