3.6 kW. PACi Elite High Static Pressure Hide Away • R32
KIT-36PF1ZH5 (S-36PF1E5B + U-36PZH2E5)
The ducted systems are the ideal solution for flexible, concealed air conditioning and the optional 200mm spigots ensure simple, hassle-free connection to spiral ductwork.
- High ESP (external static pressure) up to 150 Pa
- Automatic learning function for the required static pressure on site during commissioning (a standard wired remote controller is required)
- DC FAN for better efficiency and control
- Built in drain pump
- Datanavi simple support tool App with remote controller (CZ-RTC5B)
- Twin split options
- Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB. The external device can be controlled by the remote control of the Panasonic indoor unit
Спецификации
PACi Elite High Static Pressure Hide Away • R32 | ЕДНОФАЗНИ | ||
---|---|---|---|
3.6 kW | |||
EER (Nominal) (1) | W/W | 4,74 | |
COP (Nominal) (1) | W/W | 4,76 | |
Refrigerant (R32) / CO2 Eq. | kg / T | — | |
Kit | KIT-36PF1ZH5 | ||
Remote controller | CZ-RTC5B | ||
Cooling capacity (Nominal) | kW | 3,6 | |
Cooling capacity (Min) | kW | 1,5 | |
Cooling capacity (Max) | kW | 4,0 | |
EER (Nominal) (1) | W/W | 4,74 | |
SEER (2) | 6,1 A++ | ||
Pdesign (cooling) | kW | 3,6 | |
Input power cooling (Nominal) | kW | 0,76 | |
Annual energy consumption cooling (3) | kWh/a | 207 | |
Heating capacity (Nominal) | kW | 4,0 | |
Heating capacity (Min) | kW | 1,5 | |
Heating capacity (Max) | kW | 5,0 | |
COP (Nominal) (1) | W/W | 4,76 | |
SCOP (2) | 4,3 A+ | ||
Pdesign at -10°C | kW | 3,6 | |
Input power heating (Nominal) | kW | 0,84 | |
Annual energy consumption heating (3) | kWh/a | 1172 | |
Indoor unit | S-36PF1E5B | ||
External static pressure (Nominal) (4) | Pa | 70 | |
External static pressure (Min) (4) | Pa | 10 | |
External static pressure (Max) (4) | Pa | 150 | |
Indoor air flow (Hi) | m³/min | 14,0 | |
Indoor air flow (Med) | m³/min | 13,0 | |
Indoor air flow (Lo) | m³/min | 10,0 | |
Indoor sound pressure (Hi) (5) | dB(A) | 33 | |
Indoor sound pressure (Med) (5) | dB(A) | 29 | |
Indoor sound pressure (Lo) (5) | dB(A) | 25 | |
Indoor dimension (Height) | mm | 290 | |
Indoor dimension (Width) | mm | 800 | |
Indoor dimension (Depth) | mm | 700 | |
Indoor net weight | kg | 28 | |
Outdoor unit | U-36PZH2E5 | ||
Outdoor power source | V | 220 - 230 - 240 | |
Current in cooling (1p 220V / 3p 380) | A | 3,45 | |
Current in cooling (1p 230V / 3p 400) | A | 3,30 | |
Current in cooling (1p 240V / 3p 415) | A | 3,15 | |
Current in heating (1p 220V / 3p 380) | A | 3,85 | |
Current in heating (1p 230V / 3p 400) | A | 3,70 | |
Current in heating (1p 240V / 3p 415) | A | 3,55 | |
Outdoor air flow (Cool) | m³/min | 40 | |
Outdoor air flow (Heat) | m³/min | 40 | |
Outdoor sound pressure (Cool -Hi) | dB(A) | 43 | |
Outdoor sound pressure (Heat -Hi) | dB(A) | 44 | |
Outdoor sound power (Cool -Hi) | dB(A) | 62 | |
Outdoor sound power (Heat -Hi) | dB(A) | 64 | |
Outdoor dimension (Height) | mm | 695 | |
Outdoor dimension (Width) | mm | 875 | |
Outdoor dimension (Depth) | mm | 320 | |
Outdoor net weight | kg | 43 | |
Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | |
Pipe diameter (Gas) | Inch (mm) | 1/2 (12,70) | |
Pipe length range | m | 3 ~ 40 | |
Elevation difference (in/out) (6) | m | 30 | |
Pipe length for additional gas | m | 30 | |
Additional gas amount | g/m | 20 | |
Refrigerant (R32) / CO2 Eq. | kg / T | 1,15 / 0,776 | |
Operating range (Cool - Min) | °C | -15 | |
Operating range (Cool - Max) | °C | 46 | |
Operating range (Heat - Min) | °C | -20 | |
Operating range (Heat - Max) | °C | 24 |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) Medium External static pressure setting from factory.
(5) The sound pressure of the units shows the value measured of the position 1,5 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(6) When installing the outdoor unit at a higher position than the indoor unit.
(7) For models 100 ~ 140PZH2E5(8), it is possible to operate the lowest -20 °C in the computer rooms with the piping length of 30 m or less.
* Recommended fuse for the indoor 3 A.