16kW
KIT-AXC16K9E8 (WH-ADC16K9E8 + WH-UXZ16KE8)
Aquarea T-CAP All in One K Generation
A revolution in design, efficiency, connectivity and sustainability.Aquarea K Generation is a ground breaking low-energy system for heating, cooling and domestic hot water production that delivers outstanding performance.
Aquarea T-CAP is the range for retrofit and new builds, keeping Total Capacity even at extremely cold ambient.
A premium white, faithful to the Aquarea spirit underlined by the seamlessly integrated controller which provides a sleek black band across the unit. The All in One model maintains its compactness with its encroachment of only 599 x 602mm, comparable to a household appliance.
The outdoor units, with an Anthracite Grey colour which will dress the entire range, have been completely redesigned with an innovative design that will find its place in all spaces.
- A+++ in heating at 35°C and A+ in DHW
- “A” water pump with variable speed
- Stainless steel DHW tank with U-Vacua™ insulation panel
- 599 x 602 footprint
- Built-in magnetic water filter
- Constant capacity down to -20°C
- Operating range down to -28°C
- 60°C hot water even at -10°C outside temperature
- Optimised user interface and improved features
- Optional Aquarea Smart and Service Cloud and integration into BMS projects
Own an Aquarea? Keep it performing as its best
Specifications
| K Generation 1 phase - 3 phase · R32 | |||
|---|---|---|---|
| 16 kW | |||
| Heating capacity (A +7°C, W 35°C) | kW | 16,00 | |
| COP (A +7°C, W 35°C) | 4,38 | ||
| Heating capacity (A +2°C, W 35°C) | kW | 16,00 | |
| COP (A +2°C, W 35°C) | 3,10 | ||
| Heating capacity (A -7°C, W 35°C) | kW | 16,00 | |
| COP (A -7°C, W 35°C) | 2,39 | ||
| Cooling capacity (A 35°C, W 7°C) | kW | 13,40 | |
| EER (A 35°C, W 7°C) | 2,64 | ||
| Pipe length range | m | 3 ~ 30 | |
| Indoor dimension (Height) | mm | 1.642 | |
| Indoor net weight | kg | 103 | |
| Outdoor dimension (Height) | mm | 1.340 | |
| Outdoor net weight | kg | 103 | |
| Indoor sound pressure (Heat) | dB(A) | 33 | |
| Refrigerant (R32) / CO2 Eq. | kg / T | 1,83 / 1,235 | |
| Indoor dimension (Width) | mm | 599 | |
| Indoor dimension (Depth) | mm | 602 | |
| Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | |
| Pipe diameter (Gas) | Inch (mm) | 1/2 (12,70) | |
| Pipe length for additional gas | m | 10 | |
| Additional gas amount | g/m | 30 | |
| Kit | KIT-AXC16K9E8* | ||
| Indoor unit | WH-ADC16K9E8 | ||
| Outdoor unit | WH-UXZ16KE8 | ||
| Heating capacity (A +7°C, W 55°C) | kW | 16,00 | |
| COP (A +7°C, W 55°C) | 2,72 | ||
| Heating capacity (A +2°C, W 55°C) | kW | 16,00 | |
| COP (A +2°C, W 55°C) | 2,07 | ||
| Heating capacity (A -7°C, W 55°C) | kW | 16,00 | |
| COP (A -7°C, W 55°C) | 1,71 | ||
| Cooling capacity (A 35°C, W 18°C) | kW | 13,40 | |
| EER (A 35°C, W 18°C) | 2,64 | ||
| Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 176 / 129 | |
| Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 4,46 / 3,31 | |
| Heating average climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A++ | |
| Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 232 / 160 | |
| Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 5,88 / 4,09 | |
| Heating warm climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A+++ | |
| Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 150 / 125 | |
| Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 3,83 / 3,20 | |
| Heating cold climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A++ / A++ | |
| Indoor sound pressure (Cool) | dB(A) | 33 | |
| Water pipe connector | Inch | R 1¼ | |
| A class pump (Number of speeds) | Variable speed | ||
| Heating water flow (∆T=5 K. 35°C) | L/min | 45,9 | |
| Water volume | L | 185 | |
| Maximum water temperature | °C | 65 | |
| Material inside tank | Stainless steel | ||
| Tapping profile according EN16147 | L | ||
| DHW tank ERP average climate efficiency rating (2) | A+ to F | A | |
| DHW tank ERP warm climate efficiency rating (2) | A+ to F | A+ | |
| DHW tank ERP cold climate efficiency rating (2) | A+ to F | A | |
| DHW tank ERP average climate η | ηwh % | 107 | |
| DHW tank ERP warm climate η | ηwh % | 128 | |
| DHW tank ERP cold climate η | ηwh % | 84 | |
| Outdoor dimension (Width) | mm | 900 | |
| Outdoor dimension (Depth) | mm | 320 | |
| Elevation difference (in/out) | m | 20 | |
| Operation range - Outdoor ambient (Heat) | °C | -28 ~ +35 | |
| Operation range - Outdoor ambient (Cool) | °C | +10 ~ +43 | |
| DHW tank ERP average climate COPdHW | COPdHW | 2,68 | |
| DHW tank ERP warm climate COPdHW | COPdHW | 3,20 | |
| DHW tank ERP cold climate COPdHW | COPdHW | 2,10 | |
| Outdoor sound power (Heat) (3) | dB(A) | 65 | |
| Electrical information | WH-ADC16K9E8 | ||
| Electric backup heater | kW | 9,00 | |
| Recommended minimum cable size, supply 1 (5) | mm² | 5x1,5 | |
| Recommended minimum cable size, supply 2 (5) | mm² | 5x2,5 | |
| Recommended fuse | A | 20 / 20 | |
(2) Scale from A+ to F.
(3) Sound power in accordance to 811/2013, 813/2013 and EN12102-1:2017 at +7 °C.
(4) Check local regulations.
* EER and COP calculation is based in accordance to EN14511.
** This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.
*** Available Autumn 23.
**** Tentative data.