LZ Retro Fit 249 Inverter+ – R32

LZ – perfekt ved utskiftning av eldre varmepumpe

LZ-modellene er effektive og pålitelige ved utetemperaturer helt ned -35 °C. Den gjennomtenkte designen gjør LZ perfekt som erstatningspumpe.

 

Utforsk en ny generasjon varmepumpesystemer

Et klimaanlegg for fremtiden

Vi hjelper deg å velge riktig Panasonic-luftvarmepumpe til hjemmet

Spesifikasjoner

Se alle
LZ Retro Fit 249 Inverter+ – R32 1-FASE
2.50 kW 3.50 kW
Maximum capacity kW 6,55 7,65
Reference CS-LZ25TKE + CU-LZ25TKE CS-LZ35TKE + CU-LZ35TKE
Heating capacity (Nominal) kW 3,20 4,20
Heating capacity (Min) kW 0,85 0,85
Heating capacity (Max) kW 6,55 7,65
COP (1) W/W 5,12  4,72 
Heating capacity at -7°C (2) kW 4,00 4,60
COP at -7°C (1) W/W 2,52 2,35
Heating capacity at -15°C (2) kW 3,90 4,35
COP at -15°C (1) W/W 2,27 2,25
Heating capacity at -20°C (2) kW 3,30 3,70
COP at -20°C (1) W/W 2,04 2,03
Heating capacity at -25°C (2) kW 2,70 3,10
COP at -25°C (1) W/W 1,83 1,83
SCOP (3) 5,00 A++ 4,90 A++
SCOP tested by 3rd party laboratory DTI 5,17 * A+++ **
Pdesign at -10°C kW 3,00 3,80
Input power heating (Nominal) kW 0,63 0,89
Input power heating (Min) kW 0,17 0,17
Input power heating (Max) kW 1,77 2,30
Annual energy consumption heating (4) kWh/a 840 1086
Cooling capacity (Nominal) kW 2,50 3,50
Cooling capacity (Min) kW 0,85 0,85
Cooling capacity (Max) kW 3,00 4,00
SEER (3) 7,60 A++ 7,40 A++
Pdesign (cooling) kW 2,50 3,50
Input power cooling (Nominal) kW 0,51 0,86
Input power cooling (Min) kW 0,17 0,17
Input power cooling (Max) kW 0,70 1,08
Annual energy consumption cooling (4) kWh/a 115 166
Indoor unit CS-LZ25TKE CS-LZ35TKE
Indoor power source V 230 230
Indoor air flow (Heat) m³/min 12,5 13,0
Indoor air flow (Cool) m³/min 9,3 10,5
Moisture removal volume L/h 1,5 2,0
Indoor sound pressure (Heat -Hi) (5) dB(A) 45 46
Indoor sound pressure (Heat -Lo) (5) dB(A) 29 30
Indoor sound pressure (Heat -Q-Lo) (5) dB(A) 18 19
Indoor sound pressure (Cool -Hi) (5) dB(A) 40 43
Indoor sound pressure (Cool -Lo) (5) dB(A) 25 28
Indoor sound pressure (Cool -Q-Lo) (5) dB(A) 21 21
Indoor dimension (Height) mm 249 249
Indoor dimension (Width) mm 790 790
Indoor dimension (Depth) mm 355 355
Indoor net weight kg 11 11
Outdoor unit CU-LZ25TKE CU-LZ35TKE
Outdoor air flow (Heat) m³/min 34,0 35,6
Outdoor air flow (Cool) m³/min 33,1 34,4
Outdoor sound pressure (Heat -Hi) (5) dB(A) 44 47
Outdoor sound pressure (Cool -Hi) (5) dB(A) 43 45
Outdoor dimension (Height) (6) mm 622 622
Outdoor dimension (Width) (6) mm 824 824
Outdoor dimension (Depth) (6) mm 299 299
Outdoor net weight kg 38 38
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 3/8 (9,52) 3/8 (9,52)
Pipe length range m 3 ~ 20 3 ~ 20
Elevation difference (in/out) (7) m 10 10
Pipe length for additional gas m 7,5 7,5
Additional gas amount g/m 20 20
Refrigerant (R32) / CO2 Eq. kg / T 1,10 / 0,743 1,10 / 0,743
Operating range (Heat - Min) °C -20 -20
Operating range (Heat - Max) °C +24 +24
Operating range (Cool - Min) °C -15 -15
Operating range (Cool - Max) °C +43 +43
Lowest outdoor temperature tested by 3rd party laboratory (8) °C -35

(1) COP-beregning er basert på EN 14511.
(2) Kapasiteten til varmepumpen er testet ved maksimal effekt og avriming.
(3) Energimerking fra A+++ til D. * SCOP testet av det uavhengige testlaboratoriet DTI i henhold til EN 14825:2016. ** A+++ er beregnet basert på SCOP-test utført av Dansk Teknologisk Institut. Testrapporten fra Dansk Teknologisk Institut kan leses på lz25test.panasonic.se.
(4) Det årlige energiforbruket beregnes i henhold til EU/626/2011.
(5) Lydtrykket til innedelen viser verdien målt 1 m foran hoveddelen og 0,8 m under enheten. For utedelen er verdien målt 1 m foran og 1 m bak hoveddelen. Lydtrykket er målt i samsvar med JIS C 9612. Stille: Stille modus. Lav: Den laveste viftehastigheten.
(6) Legg til 70 mm for rørport.
(7) Når utedelen installeres i en høyere posisjon enn innedelen.
(8) Testet av DTI, et uavhengig testlaboratorium, i henhold til EN 14511:2013. Denne temperaturen garanteres ikke av fabrikken.