Model
Large capacity PACi. Trusted power and high efficiency.
- High performance turbo fan, path system for heat exchanger
- nanoe™ X that improves indoor air quality
- Econavi: Intelligent sensor to reduce waste of energy
- Datanavi simple support tool App with remote controller (CZ-RTC5B)
- Lower noise in slow fan operation
- Light weight, easy piping
- Drain pump included
Naturalny balans w Twoim domu
Dane techniczne
| PACi Standard 4 Way 90x90 • R32 | 1-FAZOWE | 3-FAZOWE | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 6.0 kW | 7.1 kW | 10.0 kW | 12.5 kW | 14.0 kW | 10.0 kW | 12.5 kW | 14.0 kW | |||
| Komplet | KIT-60PU2Z5 | KIT-71PU2Z5 | KIT-100PU2Z5 | KIT-125PU2Z5 | KIT-140PU2Z5 | KIT-100PU2Z8 | KIT-125PU2Z8 | KIT-140PU2Z8 | ||
| Zdalny sterownik | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | ||
| Wydajność chłodnicza (nominalna) | kW | 6,0 | 7,1 | 10,0 | 12,5 | 14,0 | 10,0 | 12,5 | 14,0 | |
| Wydajność chłodnicza (Min) | kW | 2,0 | 2,0 | 3,0 | 3,2 | 3,3 | 3,0 | 3,2 | 3,3 | |
| Wydajność chłodnicza (Max) | kW | 7,1 | 7,7 | 11,5 | 13,5 | 15,0 | 11,5 | 13,5 | 15,0 | |
| Współczynnik EER (nominalny) (1) | W/W | 4,00 | 3,50 | 3,82 | 3,58 | 3,23 | 3,82 | 3,58 | 3,23 | |
| Współczynnik EER (Min) (1) | W/W | 5,36 | 5,33 | 5,32 | 5,36 | 5,33 | 5,32 | |||
| Współczynnik EER (Max) (1) | W/W | 2,88 | 2,81 | 2,73 | 2,88 | 2,81 | 2,73 | |||
| Współczynnik SEER (2) | 7,6 A++ | 7,6 A++ | 6,8 A++ | 6,8 | 6,5 | 6,7 A++ | 6,7 | 6,5 | ||
| Moc projektowa Pdesign (chłodzenie) | kW | 6,0 | 7,1 | 10,0 | 12,5 | 14,0 | 10,0 | 12,5 | 14,0 | |
| Zasilanie wejściowe w trybie chłodzenia (nominalne) | kW | 1,50 | 2,03 | 2,62 | 3,49 | 4,34 | 2,62 | 3,49 | 4,34 | |
| Roczne zużycie energii w trybie chłodzenia (3) | kWh/a | 276 | 327 | 515 | — | — | 521 | — | — | |
| Moc wejściowa chłodzenia (Min) | kW | 0,56 | 0,60 | 0,62 | 0,56 | 0,60 | 0,62 | |||
| Moc wejściowa chłodzenia (Max) | kW | 4,00 | 4,80 | 5,50 | 4,00 | 4,80 | 5,50 | |||
| Roczne zużycie energii w trybie chłodzenia (3) | kWh/a | 276 | 327 | 515 | — | — | 521 | — | — | |
| Wydajność ogrzewania (nominalna) | kW | 6,0 | 7,1 | 10,0 | 12,5 | 14,0 | 10,0 | 12,5 | 14,0 | |
| Wydajność grzewcza (Min) | kW | 1,8 | 1,8 | 3,0 | 3,3 | 3,4 | 3,0 | 3,3 | 3,4 | |
| Wydajność grzewcza (Max) | kW | 7,0 | 8,1 | 14,0 | 15,0 | 16,0 | 14,0 | 15,0 | 16,0 | |
| Współczynnik COP (nominalny) (1) | W/W | 4,72 | 4,36 | 4,93 | 4,43 | 4,18 | 4,93 | 4,43 | 4,18 | |
| Współczynnik COP (Min) (1) | W/W | 3,59 | 3,57 | 3,33 | 3,59 | 3,57 | 3,33 | |||
| Współczynnik COP (Max) (1) | W/W | 5,36 | 5,50 | 5,48 | 5,36 | 5,50 | 5,48 | |||
| Współczynnik SCOP (2) | 4,7 A++ | 4,7 A++ | 4,4 A+ | 4 | 3,9 | 4,4 A+ | 4 | 3,9 | ||
| Moc projektowa Pdesign przy -10°C | kW | 6,0 | 6,0 | 10,0 | 12,5 | 14,0 | 10,0 | 12,5 | 14,0 | |
| Zasilanie wejściowe w trybie ogrzewania (nominalne) | kW | 1,27 | 1,63 | 2,03 | 2,82 | 3,35 | 2,03 | 2,82 | 3,35 | |
| Moc wejściowa ogrzewania (Min) | kW | 0,56 | 0,60 | 0,62 | 0,56 | 0,60 | 0,62 | |||
| Moc wejściowa ogrzewania (Max) | kW | 3,90 | 4,20 | 4,80 | 3,90 | 4,20 | 4,80 | |||
| Roczne zużycie energii w trybie ogrzewania (3) | kWh/a | 1787 | 1787 | 3182 | — | — | 3182 | — | — | |
| Jednostka wewnętrzna | S-60PU2E5B | S-71PU2E5B | S-100PU2E5B | S-125PU2E5B | S-140PU2E5B | S-100PU2E5B | S-125PU2E5B | S-140PU2E5B | ||
| Przepływ powietrza jednostki wew. (Hi) | m³/min | 21,0 | 22,0 | 36,0 | 37,0 | 38,0 | 36,0 | 37,0 | 38,0 | |
| Przepływ powietrza jednostki wew. (Med) | m³/min | 16,0 | 16,0 | 26,0 | 27,0 | 29,0 | 26,0 | 27,0 | 29,0 | |
| Przepływ powietrza jednostki wew. (Lo) | m³/min | 13,0 | 13,0 | 18,0 | 19,0 | 20,0 | 18,0 | 19,0 | 20,0 | |
| Pojemność usuwania wilgoci | L/h | 1,7 | 2,5 | 2,7 | 4,8 | 6,0 | 2,7 | 4,8 | 6,0 | |
| Ciśnienie akustyczne jednostki wew. (Med) (4) | dB(A) | 31 | 31 | 38 | 39 | 40 | 38 | 39 | 40 | |
| Ciśnienie akustyczne jednostki wew. (Lo) (4) | dB(A) | 28 | 28 | 32 | 33 | 34 | 32 | 33 | 34 | |
| Moc akustyczna jednostki wew. (Hi) | dB(A) | 51 | 52 | 60 | 61 | 62 | 60 | 61 | 62 | |
| Moc akustyczna jednostki wew. (Med) | dB(A) | 46 | 46 | 53 | 54 | 55 | 53 | 54 | 55 | |
| Moc akustyczna jednostki wew. (Lo) | dB(A) | 43 | 43 | 47 | 48 | 49 | 47 | 48 | 49 | |
| Wymiary jednostki wewnętrznej (wysokość) | mm | 256 | 256 | 319 | 319 | 319 | 319 | 319 | 319 | |
| Wymiary jednostki wew. (szerokość) | mm | 840 | 840 | 840 | 840 | 840 | 840 | 840 | 840 | |
| Wymiary jednostki wew. (głębokość) | mm | 840 | 840 | 840 | 840 | 840 | 840 | 840 | 840 | |
| Wymiary panelu (Wysokość) | mm | 33,5 | 33,5 | 33,5 | 33,5 | 33,5 | 33,5 | 33,5 | 33,5 | |
| Wymiary panelu (Głębokość) | mm | 950 | 950 | 950 | 950 | 950 | 950 | 950 | 950 | |
| Ciężar netto jednostki wewnętrznej | kg | 20 | 20 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Ciężar netto panelu | kg | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |
| Generator nanoe X | Mark 1 | Mark 1 | Mark 1 | Mark 1 | Mark 1 | Mark 1 | Mark 1 | Mark 1 | ||
| Jednostka zewnętrzna | U-60PZ2E5 | U-71PZ2E5 | U-100PZ2E5 | U-125PZ2E5 | U-140PZ2E5 | U-100PZ2E8 | U-125PZ2E8 | U-140PZ2E8 | ||
| Zewnętrzne źródło zasilania | V | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | |
| Prąd w trybie chłodzenia (1p 220V / 3p 380) | A | 7,40 | 9,95 | 12,10 | 16,30 | 20,40 | 4,10 | 5,45 | 6,85 | |
| Prąd w trybie chłodzenia (1p 230V / 3p 400) | A | 7,05 | 9,50 | 11,50 | 15,60 | 19,50 | 3,90 | 5,20 | 6,50 | |
| Prąd w trybie chłodzenia (1p 240V / 3p 415) | A | 6,75 | 9,10 | 11,10 | 15,00 | 18,70 | 3,75 | 5,00 | 6,25 | |
| Prąd w trybie ogrzewania (1p 220V / 3p 380) | A | 6,25 | 8,05 | 9,25 | 13,10 | 15,60 | 3,15 | 4,40 | 5,25 | |
| Prąd w trybie ogrzewania (1p 230V / 3p 400) | A | 5,95 | 7,70 | 8,85 | 12,60 | 15,00 | 3,00 | 4,15 | 4,95 | |
| Prąd w trybie ogrzewania (1p 240V / 3p 415) | A | 5,70 | 7,35 | 8,50 | 12,00 | 14,30 | 2,90 | 4,00 | 4,80 | |
| Przepływ powietrza jednostki zew. (Chłodzenie) | m³/min | 40 | 50 | 76 | 86 | 89 | 76 | 86 | 89 | |
| Przepływ powietrza jednostki zew. (Ogrzewanie) | m³/min | 45 | 45 | 70 | 78 | 83 | 70 | 78 | 83 | |
| Ciśnienie akustyczne jednostki zew. (Cool -Hi) | dB(A) | 46 | 49 | 52 | 55 | 56 | 52 | 55 | 56 | |
| Ciśnienie akustyczne jednostki zew. (Heat -Hi) | dB(A) | 48 | 49 | 52 | 55 | 56 | 52 | 55 | 56 | |
| Ciśnienie akustyczne jednostki zew. (Cool -Hi) | dB(A) | 65 | 69 | 70 | 73 | 74 | 70 | 73 | 74 | |
| Ciśnienie akustyczne jednostki zew. (Heat -Hi) | dB(A) | 68 | 69 | 70 | 73 | 74 | 70 | 73 | 74 | |
| Wymiary jednostki zewnętrznej (wysokość) | mm | 695 | 695 | 996 | 996 | 996 | 996 | 996 | 996 | |
| Wymiary jednostki zew. (Szerokość) | mm | 875 | 875 | 980 | 980 | 980 | 980 | 980 | 980 | |
| Wymiary jednostki zew. (Głębokość) | mm | 320 | 320 | 370 | 370 | 370 | 370 | 370 | 370 | |
| Ciężar netto jednostki zewnętrznej | kg | 44 | 44 | 90 | 94 | 94 | 90 | 94 | 94 | |
| Średnica rury (ciecz) | Inch (mm) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | |
| Średnica rury (LPG) | Inch (mm) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | |
| Zakres długości orurowania | m | 3 ~ 40 | 3 ~ 40 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | |
| Różnica wysokości (wew./zew.) (5) | m | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
| Długość rury dla dodatkowego gazu | m | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
| Dodatkowy gaz chłodniczy | g/m | 35 | 35 | 45 | 45 | 45 | 45 | 45 | 45 | |
| Czynnik chłodniczy (R32) / CO2 Eq. | kg / T | 1,45 / 0,979 | 1,45 / 0,979 | 2,60 / 1,755 | 2,98 / 2,0115 | 2,98 / 2,0115 | 2,60 / 1,755 | 2,98 / 2,0115 | 2,98 / 2,0115 | |
| Zakres roboczy (min.-maks.) | °C | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | |
| Zakres roboczy (chłodzenie - Max) | °C | 43 | 43 | 43 | 43 | 43 | 43 | 43 | 43 | |
| Zakres roboczy (ogrzewanie - Min) | °C | -15 | -15 | -15 | -15 | -15 | -15 | -15 | -15 | |
| Zakres roboczy (ogrzewanie - Max) | °C | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the units shows the value measured of the position 1,5 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(5) When installing the outdoor unit at a higher position than the indoor unit.
* Recommended fuse for the indoor 3 A.