PACi NX serija Elite adaptivna kanalska jedinica s inverterom + - R32

Asortiman kanalskih jedinica dizajna PF3

2 mogućnosti za ugradnju (horizontalno/vertikalno) sa visokim eksternim statičkim pritiskom od 150 Pa omogućava fleksibilnu instalaciju.

* Prema internoj anketi kompanije Panasonic, performanse nanoe™ X vazduha mogu se očekivati čak i kod kanala dugih 10 m.

Sledeća generacija komercijalnih klima-uređaja je stigla

Nova adaptivna kanalska jedinica PF3

Sledeća generacija komercijalnih klima-uređaja je stigla

Specifikacije

Pogledaj sve
PACi NX serija Elite adaptivna kanalska jedinica s inverterom + - R32
12.5 kW
Kit KIT-125PF3ZH48
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 12,1
Cooling capacity (Min) kW 3,2
Cooling capacity (Max) kW 13,6
EER (Nominal) (1) W/W 3,53
EER (Min) (1) W/W 3,00
EER (Max) (1) W/W 5,00
SEER/ηsc (2) % 281,0%
Pdesign (cooling) kW 12,1
Input power cooling (Nominal) kW 3,43
Input power cooling (Min) kW 0,64
Input power cooling (Max) kW 4,54
Annual energy consumption cooling (3) kWh/a
Heating capacity (Nominal) kW 13,5
Heating capacity (Min) kW 3,2
Heating capacity (Max) kW 15,4
COP (Nominal) (1) W/W 3,46
COP (Min) (1) W/W 3,06
COP (Max) (1) W/W 5,16
SCOP/ηsc (2) % 165,0%
Pdesign at -10°C kW 9,3
Input power heating (Nominal) kW 3,90
Input power heating (Min) kW 0,62
Input power heating (Max) kW 5,04
Annual energy consumption heating (3) kWh/a
Indoor unit S-1014PF3E
External static pressure (Nominal) (4) Pa 50
External static pressure (Min) (4) Pa 10
External static pressure (Max) (4) Pa 150
Moisture removal volume L/h 34,0
Indoor air flow (Hi) m³/min 29,0
Indoor air flow (Med) m³/min 23,0
Indoor air flow (Lo) m³/min 4,1
Indoor sound pressure (Hi) (5) dB(A) 35
Indoor sound pressure (Med) (5) dB(A) 31
Indoor sound pressure (Lo) (5) dB(A) 27
Indoor sound power (Hi) dB(A) 58
Indoor sound power (Med) dB(A) 54
Indoor sound power (Lo) dB(A) 50
Indoor dimension (Height) mm 250
Indoor dimension (Width) mm 1.400
Indoor dimension (Depth) mm 730
Indoor net weight kg 39
nanoe X Generator Mark 2
Outdoor unit U-125PZH4E8
Outdoor power source V 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 5,65
Current in cooling (1p 230V / 3p 400) A 5,40
Current in cooling (1p 240V / 3p 415) A 5,20
Current in heating (1p 220V / 3p 380) A 6,50
Current in heating (1p 230V / 3p 400) A 6,20
Current in heating (1p 240V / 3p 415) A 5,95
Outdoor air flow (Cool) m³/min 86,0
Outdoor air flow (Heat) m³/min 78,0
Outdoor sound pressure (Cool -Hi) dB(A) 55
Outdoor sound pressure (Heat -Hi) dB(A) 55
Outdoor sound power (Cool -Hi) dB(A) 73
Outdoor sound power (Heat -Hi) dB(A) 73
Outdoor dimension (Height) mm 996
Outdoor dimension (Width) mm 980
Outdoor dimension (Depth) mm 370
Outdoor net weight kg 84
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 100
Elevation difference (in/out) (8) m 15 / 30
Pipe length for additional gas m 30
Additional gas amount g/m 40
Refrigerant (R32) / CO2 Eq. kg / T 3,00 / 2,03
Operating range (Cool - Min) °C -20 (9)
Operating range (Cool - Max) °C +52
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C +24

1) Izračunavanje vrednosti EER i COP je zasnovano na standardu EN14511.
2) Za modele ispod 12 kW, SEER i SCOP se proračunavaju na osnovu vrednosti EU/626/2011. Za modele iznad 12 kW, ηsc/ηsh vrednosti se izračunavaju na osnovu standarda EN 14825.
3) Fabričko podešavanje.
4) Srednje podešavanja spoljašnjeg statičkog pritiska u fabrici.
5) Zvučni pritisak jedinica prikazuje vrednost izmerenu za položaj 1,5 m ispod jedinice. Zvučni pritisak se meri u skladu sa specifikacijom Eurovent 6/C/006-97.
6) Povežite priključnu cev za tečnost (Ø6,35 – Ø9,52) na strani sa cevima za tečnost kod unutrašnje jedinice
7) Povežite priključnu cev za gas (Ø12,70 – Ø15,88) na strani sa cevima za gas kod unutrašnje jedinice. 8) Spoljašnja jedinica postavljena je na nižem položaju / spoljašnja jedinica postavljena je na višem položaju.
9) Dužina cevi do 30 m.
* Preporučena snaga osigurača za unutrašnju ugradnju iznosi 3 A.

** Navedene vrednosti važe u slučaju standardne instalacije (horizontalna instalacija u plafonu, ulaz vazduha sa zadnje strane) i kada je nanoe™ X ISKLJUČEN.

Dodatni proizvodi