K Generation 1 phase · R32

Aquarea High Performance Bi-bloc K Generation Single phase

A revolution in design, efficiency, connectivity and sustainability.
Aquarea K Generation is a ground breaking low-energy system for heating, cooling and domestic hot water production that delivers outstanding performance. This model is ideal for new installations and well-insulated homes.
Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.
A premium white, faithful to the Aquarea spirit underlined by the seamlessly integrated controller which provides a sleek black band across the unit.
The outdoor units, with an Anthracite Grey colour which will dress the entire range, have been completely redesigned with an innovative design that will find its place in all spaces.

Imate Aquarea?

Specifikacije

Pogledaj sve
K Generation 1 phase · R32 JEDNOFAZNO
3 kW 5 kW 7 kW 9 kW 12 kW
Kit 3kW electric heater KIT-WC03K3E5 KIT-VC05K3E5 KIT-VC07K3E5 KIT-VC09K3E5
Kit 6kW electric heater KIT-WC03K6E5 KIT-VC05K6E5 KIT-VC07K6E5 KIT-VC09K6E5 KIT-WC12K6E5*
Heating capacity (A +7°C, W 35°C) kW 3,2 5 7 9 12,10
COP (A +7°C, W 35°C) 5,33 5,1 4,86 4,55 4,78
Heating capacity (A +7°C, W 55°C) kW 3,2 5 7 8,9 12,00
COP (A +7°C, W 55°C) 2,81 3,03 2,92 2,93 2,96
Heating capacity (A +2°C, W 35°C) kW 3,2 5 6,85 7 11,50
COP (A +2°C, W 35°C) 3,64 3,57 3,43 3,4 3,44
Heating capacity (A +2°C, W 55°C) kW 3,2 5 6,25 6,3 9,20
COP (A +2°C, W 55°C) 2,19 2,29 2,23 2,18 2,25
Heating capacity (A -7°C, W 35°C) kW 3,3 5 5,75 6,25 10,10
COP (A -7°C, W 35°C) 2,8 2,79 2,95 2,84 2,74
Heating capacity (A -7°C, W 55°C) kW 3,2 5 5,35 5,9 8,40
COP (A -7°C, W 55°C) 1,79 1,89 1,98 1,93 1,97
Cooling capacity (A 35°C, W 7°C) kW 3,2 5 6,7 8,2 10,70
EER (A 35°C, W 7°C) 3,52 3,05 3,03 2,72 2,68
Cooling capacity (A 35°C, W 18°C) kW 3,2 5 6,7 9 10,70
EER (A 35°C, W 18°C) 4,71 4,9 4,72 4,18 3,92
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 5,07 / 3,47 5,12 / 3,63 4,90 / 3,62 4,44 / 3,41 4,58 / 3,33
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 200 / 136 202 / 142 193 / 142 175 / 133 180 / 130
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++ A++/A++ A++/A++ A++/A++ A+++ / A++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,20 / 4,20 6,00 / 4,20 5,75 / 4,07 5,75 / 4,07 6,47 / 4,34
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 245 / 165 237 / 165 227 / 160 227 / 160 256 / 171
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,00 / 2,83 4,08 / 2,95 4,18 / 2,98 4,18 / 2,98 4,31 / 3,26
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 157 / 110 160 / 115 164 / 116 164 / 116 169 / 127
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A+ A++ / A+ A++ / A+ A++ / A+ A++ / A++
Indoor unit 3kW electric heater WH-SDC0309K3E5 VH-SDC0309K3E5 VH-SDC0309K3E5 VH-SDC0309K3E5
Indoor unit 6kW electric heater WH-SDC0309K6E5 VH-SDC0309K6E5 VH-SDC0309K6E5 VH-SDC0309K6E5 WH-SDC12K6E5
Indoor sound pressure (Heat) dB(A) 28 28 30 30 33
Indoor sound pressure (Cool) dB(A) 28 28 30 31 33
Indoor dimension (Height) mm 892 892 892 892 892
Indoor dimension (Width) mm 500 500 500 500 500
Indoor dimension (Depth) mm 348 348 348 348 348
Indoor net weight kg 40 (3kW) / 41 (6kW) 40 (3kV) / 41 (6kV) 40 (3kV) / 41 (6kV) 40 (3kV) / 41 (6kV) 41
Water pipe connector Inch R 1¼ R 1¼ R 1¼ R 1¼ R 1¼
A class pump (Number of speeds) Variable speed Promenljiva brzina Promenljiva brzina Promenljiva brzina Variable speed
Heating water flow (∆T=5 K. 35°C) L/min 9,2 14,3 20,1 25,8 34,4
Outdoor unit WH-UDZ03KE5 VH-UDZ05KE5 VH-UDZ07KE5 VH-UDZ09KE5 WH-UDZ12KE5
Outdoor sound power (Heat) (2) dB(A) 55 55 56 56 65
Outdoor dimension (Height) mm 622 795 795 795 1.340
Outdoor dimension (Width) mm 824 875 875 875 900
Outdoor dimension (Depth) mm 298 380 380 380 320
Outdoor net weight kg 37 55 55 55 88
Refrigerant (R32) / CO2 Eq. kg / T 0,9 / 0,608 1,3 / 0,878 1,3 / 0,878 1,3 / 0,878 1,6 / 1,080
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 1/2 (12,7)
Pipe length range m 3 ~ 25 3 ~ 40 (3 ~ 50) (3) 3 ~ 40 (3 ~ 50) (3) 3 ~ 40 (3 ~ 50) (3) 3 ~ 30
Elevation difference (in/out) m 20 30 30 30 20
Pipe length for additional gas m 10 10 10 10 10
Additional gas amount g/m 20 25 25 25 30
Operation range - Outdoor ambient (Heat) °C -20 ~ +35 -25 ~ +35 -25 ~ +35 -25 ~ +35 -25 ~ +35
Operation range - Outdoor ambient (Cool) °C +10 ~ +43 +10 ~ +43 +10 ~ +43 +10 ~ +43 +10 ~ +43
Electrical information 3kW — 6kW 3kV — 6kV 3kV — 6kV 3kV — 6kV 6kW
Electric backup heater kW 3,00 — 6,00 3,00 — 6,00 3,00 — 6,00 3,00 — 6,00 6,00
Recommended fuse A 16 / 16 — 16 / 30 16 / 16 — 16 / 30 25 / 16 — 25 / 30 25 / 16 — 25 / 30 30 / 30
Recommended minimum cable size, supply 1 (5) mm² 3x1,5 — 3x1,5 3k1,5 — 3k1,5 3k2,5 — 3k2,5 3k2,5 — 3k2,5 3x4,0
Recommended minimum cable size, supply 2 (5) mm² 3x1,5 — 3x4,0 3k1,5 — 3k4,0 3k1,5 — 3k4,0 3k1,5 — 3k4,0 3x4,0
(1) Scale from A+++ to D.
(2) Sound power in accordance to 811/2013, 813/2013 and EN12102-1:2017 at +7°C.
(3) Operation range down to -25°C in heating with 3 ~ 40m pipe length range, operation range down to -15°C in heating with 3 ~ 50m pipe length range.
(4) Check local regulations.
* EER and COP calculation is based in accordance to EN14511.
** This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.
*** Available Autumn 23.

Dodatni proizvodi