PACi Elite Ceiling • R32
10.0kW
KIT-100PT2ZH8 (S-100PT2E5B + U-100PZH2E8)
Ceiling mounted units provides large and wide air distribution which is good for big rooms. The height and depth of all capacities are the same for unified appearance in mixed installations.
- Wide air distribution for large rooms
- Horizontal air flow reaches maximum 9,5 m
- Fresh air connection available on the unit
- Slim design with 235 m height fits narrow space
- Silent operation
- Datanavi simple support tool App with remote controller (CZ-RTC5B)
- Twin, Triple and Double-twin split options
- Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB. The external device can be controlled by the remote control of the Panasonic indoor unit
Specifikacije
| PACi Elite Ceiling • R32 | |||
|---|---|---|---|
| 10.0 kW | |||
| Komplet | KIT-100PT2ZH8 | ||
| Daljinski upravljac | CZ-RTC5B | ||
| Kapacitet hlađenja (nominalno) | kW | 10,0 | |
| Kapacitet hlađenja (min) | kW | 3,1 | |
| Kapacitet hlađenja (maks.) | kW | 12,5 | |
| EER (nominalno) (1) | W/W | 4,05 | |
| SEER (2) | 6,9 A++ | ||
| Pdesign (hlađenje) | kW | 10,0 | |
| Hlađenje- ulazna električna snaga (nominalno) | kW | 2,47 | |
| Godišnja potrošnja energije hlađenje (3) | kWh/a | 507 | |
| Godišnja potrošnja energije hlađenje (3) | kWh/a | 507 | |
| Kapacitet grejanja (nominalno) | kW | 11,2 | |
| Kapacitet zagrevanja (min.) | kW | 3,1 | |
| Kapacitet zagrevanja (maks.) | kW | 14,0 | |
| COP (nominalno) (1) | W/W | 4,31 | |
| OP (2) | 4,6 A++ | ||
| Rute u -10°C | kW | 8,0 | |
| Ulazna energija grejanja (nominalno) | kW | 2,60 | |
| Godišnja potrošnja energije grejanje (3) | kWh/a | 2435 | |
| Unutrašnje jedinice | S-100PT2E5B | ||
| Protok vazduha u zatvorenom prostoru (Hi) | m³/min | 30,0 | |
| Protok vazduha u zatvorenom prostoru (Med) | m³/min | 25,0 | |
| Protok vazduha u zatvorenom prostoru (Lo) | m³/min | 23,0 | |
| Unutrašnja zvučni pritisak (Med) (4) | dB(A) | 37 | |
| Zvučni pritisak u zatvorenom prostoru (Lo) (4) | dB(A) | 35 | |
| Unutrašnja jedinica-dimenzije (visina) | mm | 235 | |
| Unutrašnja jedinica (širina) | mm | 1590 | |
| Dimenzije u zatvorenom prostoru (dubina) | mm | 690 | |
| Unutrašnja jedinica-neto težina | kg | 40 | |
| Spoljna jedinica | U-100PZH2E8 | ||
| Spoljnia jedinica- izvor napajanja | V | 380 - 400 - 415 | |
| Struja- hlađenje (1p 220V / 3p 380) | A | 3,85 | |
| Struja -hlađenje (1p 230V / 3p 400) | A | 3,65 | |
| Struja -hlađenje (1p 240V / 3p 415) | A | 3,55 | |
| Struja- grejanje (1p 220V / 3p 380) | A | 4,05 | |
| Struja- grejanje (1p 230V / 3p 400) | A | 3,85 | |
| Struja- grejanje (1p 240V / 3p 415) | A | 3,75 | |
| Protok vazduha na otvorenom (hlađenje) | m³/min | 118 | |
| Spoljna jedinica protok vazduha (grejanje) | m³/min | 108 | |
| Spoljna zvučni pritisak (hladno -Hi) | dB(A) | 52 | |
| Spoljna zvučni pritisak (toplo - Hi) | dB(A) | 52 | |
| Spoljna zvučna snaga (hladno- Hi) | dB(A) | 69 | |
| Spoljna zvučna snaga (toplo - Hi) | dB(A) | 69 | |
| Spoljna jedinica- dimenzija (visina) | mm | 1416 | |
| Spoljna j. dimenzija (širina) | mm | 940 | |
| Spoljna j. dimenzija (dubina) | mm | 340 | |
| Spoljna jedinica-neto težina | kg | 99 | |
| Prečnik cevi (tečno) | Inch (mm) | 3/8 (9,52) | |
| Prečnik cevi (gas) | Inch (mm) | 5/8 (15,88) | |
| Opseg dužine cevi | m | 5 ~ 85 | |
| Razlika u visini (ulaz/izlaz) (5) | m | 30 | |
| Dužina cevi za dodatni gas | m | 30 | |
| Dodatna količina gasa | g/m | 45 | |
| Rashladno sredstvo (R32) / CO2 Eq. | kg / T | 3,05 / 2,059 | |
| Opseg rada (hladno – Min) | °C | -20 (6) | |
| Opseg rada (hlađenje – maks.) | °C | 46 | |
| Opseg rada (grejanje – min) | °C | -20 | |
| Opseg rada (grejanje – maks.) | °C | 24 | |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the units shows the value measured of the position 1 m in front of the main body and 1 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(5) When installing the outdoor unit at a higher position than the indoor unit.
(6) For models 100 ~ 140PZH2E5(8), it is possible to operate the lowest -20 °C in the computer rooms with the piping length of 30 m or less.
* Recommended fuse for the indoor 3 A.