PACi Standard Low Static Pressure Hide Away • R410A
6.0kW
KIT-60PNY1E5C (S-60PN1E5B + U-60PEY2E5)
The depth of only 250mm provides greater installation flexibility and the unit can be used in more applications. Ideal for sites with narrow ceiling voids.
- Automatic learning function for the required static pressure on site during commissioning (a standard wired remote controller is required. S-60/71/100/125/140PN1E5B models only)
- Compact indoor units without loosing static pressure (only 250 mm high)
- 50 Pa static pressure
- Easy maintenance and service via external electrical box
- 3 speed centrifugal fan through wired or Infrared remote controller
- DC FAN for better efficiency and control
- Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB. The external device can be controlled by the remote control of the Panasonic indoor unit
Широка гама от продукти за търговски обекти,
офиси или жилищни сгради
Системи въздух-въздух за търговски обекти
Широка гама от продукти за търговски обекти,
офиси или жилищни сгради
Системи въздух-въздух за търговски обекти
Спецификации
| PACi Standard Low Static Pressure Hide Away • R410A | |||
|---|---|---|---|
| 6.0 kW | |||
| EER (номинален) (1) | W/W | 3,21 (5,00 - 2,78) A | |
| COP (номинален) (1) | W/W | 3,73 (5,14 - 3,78) A | |
| EER (номинален) (1) | W/W | 3,21 (5,00 - 2,78) A | |
| Мощност на отопление при -7 °C (2) | kW | — | |
| Мощност на отопление при -15 °C (2) | kW | — | |
| COP (номинален) (1) | W/W | 3,73 (5,14 - 3,78) A | |
| Външно статично налягане (Номинално) (5) | Pa | 25 | |
| Външно статично налягане (Мин.) (5) | Pa | 10 | |
| Външно статично налягане (Макс.) (5) | Pa | 80 | |
| Звуково налягане на вътрешното тяло (В) (6) | dB(A) | 43 | |
| Звуково налягане на вътрешното тяло (Ср.) (6) | dB(A) | 41 | |
| Звуково налягане на вътрешното тяло (Н) (6) | dB(A) | 36 | |
| Денивелация (вътр./външно) (7) | m | 30 | |
| Хладилен агент (R410A)/CO2 екв. | kg / T | 1,95 / 4,0716 | |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) Heating capacity is calculated including defrost factor correction.
(5) Medium external static pressure setting from factory.
(6) The sound pressure of the units shows the value measured of the position 1,5 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(7) Add 100 mm for piping port.
(8) When installing the outdoor unit at a higher position than the indoor unit.
* Recommended fuse for the indoor 3 A.