Accessories and control – iCORE
Control panels and electric expansion valves for OCU‑CR and OCU‑CRC units
Control panel (Panel-C) with electric expansion valves (EEV) included.
Panel-C includes MPXPRO control, stator, probes, etc.
KIT-CO2-PANEL-C-03: EEV size E2V03CWAC0
KIT-CO2-PANEL-C-05: EEV size E2V05CWAC0
KIT-CO2-PANEL-C-09: EEV size E2V09CWAC0
KIT-CO2-PANEL-C-11: EEV size E2V11CWAC0
KIT-CO2-PANEL-C-14: EEV size E2V14CWAC0
KIT-CO2-PANEL-C-18: EEV size E2V18CWAC0
KIT-CO2-PANEL-C-24: EEV size E2V24CWAC0
KIT-CO2-PANEL-C-30: EEV size E3V30CWM00
Find out more
Cold room management via condensing unit interface - Options 1-2-3 + Cold room display. Available for OCU‑CRC units
OPTION 1
Room board for EEV control connection box*.
* Room board for 1×EEV control allows to connect Carel, Danfoss and Saginomiya EEV.
CZ-CO2-EEV-BOX
OPTION 2
Room board for EEV control connection kit*.
* Room board for 1×EEV control allows to connect Carel, Danfoss and Saginomiya EEV. KIT includes sensors.
CZ-CO2-EEV-KIT
OPTION 3
Room board for EEV control connection kit, with sensors and EEV.
CZ-CO2-EEV-KIT-03: EEV size E2V03CWAC0
CZ-CO2-EEV-KIT-05: EEV size E2V05CWAC0
CZ-CO2-EEV-KIT-09: EEV size E2V09CWAC0
CZ-CO2-EEV-KIT-11: EEV size E2V11CWAC0
CZ-CO2-EEV-KIT-14: EEV size E2V14CWAC0
CZ-CO2-EEV-KIT-18: EEV size E2V18CWAC0
CZ-CO2-EEV-KIT-24: EEV size E2V24CWAC0
CZ-CO2-EEV-KIT-30: EEV size E2V30CWAC0
CZ-CO2-DISPLAY
Wall‑mounted LED display. To be combined with options 1-2-3.
CO₂ service checker. Available for OCU‑CR units
External CO₂ receivers. Available for OCU‑CRC units
CZ-CO2-R24L80-H
External CO2 receiver, 24 L 80 bar, Housed (up to 8 kg additional refrigerant volume). Delivered with proper insulation.
CZ-CO2-R24L90-H
External CO2 receiver, 24 L 90 bar, Housed (up to 8 kg additional refrigerant volume). Delivered with proper insulation.
CZ-CO2-R24L80-E
External CO2 receiver, 24 L 80 bar, non-housed (up to 8 kg additional refrigerant volume). Delivered with proper insulation.
CZ-CO2-R24L90-E
External CO2 receiver, 24 L 90 bar, non-housed (up to 8 kg additional refrigerant volume). Delivered with proper insulation.
Accessories (model-specific compatibility - see individual descriptions)
SPK-TU125
Service adaptor for vacuum and service (HP and LP port). Available for OCU‑CR units*.
* 2 pcs. are recommended for OCU‑CR2000VF8A.
CZ-CO2LBROL500
Lubrication oil PZ-68S (0,5L) for OCU‑CR and OCU‑CRC units*.
* You can find the PZ-68S oil “Safety Sheet” in the SAFETY section of our pipe selection software, available on our PRO Club platform.
PAW-CO2-PRV60
Pressure release valve (PRV) ⅜” (9,52) NPT x G ½” (12,70) Pset= 60,0 bar (PRV for suction line all units*)
PAW-CO2-PRV80
Pressure release valve (PRV) ⅜” (9,52) NPT x G ½” (12,70) Pset= 80,0bar (PRV for suction line all units* or PRV for liquid receiver for OCU‑CR400VF8(A), OCU‑CR1000VF8(A) and OCU‑CR2000VF8A).
* For OCU‑CRC units a suction PRV is available also as customization option.
PAW-CO2-PRV120
Pressure release valve (PRV) ⅜” (9,52) NPT x G ½” (12,70) Pset= 120,0bar (PRV for liquid receiver, for OCU‑CR200VF5A).
PAW-SGT-GLASS-1/4
Sight glass, 130bar, ¼” (6,35) ODS. For OCU‑CR and OCU‑CRC units.
PAW-SGT-GLASS-3/8
Sight glass, 130bar, ⅜” (9,52) ODS. For OCU‑CR and OCU‑CRC units.
PAW-SGT-GLASS-1/2
Sight glass, 130bar, ½” (12,70) ODS. For OCU‑CR and OCU‑CRC units.
PAW-SGT-GLASS-5/8
Sight glass, 130bar, ⅝” (15,88) - 16mm ODS. For OCU‑CR and OCU‑CRC units.
PAW-SGT-GLASS-3/4
Sight glass, 130bar, ¾” (19,05) ODS. For OCU‑CR and OCU‑CRC units.
PAW-CO2-CHANGE-O
Changeover valve, ⅜” (9,52) NPT x ⅜” (9,52) NPT. For OCU‑CR and OCU‑CRC units.
PAW-CO2-RACORD-3/8
Racord ⅜” (9,52) NPT x ⅜” (9,52) ODS (for K65 pipe connection). For OCU‑CR and OCU‑CRC units.
PAW-CO2-RACORD-1/2
Racord ⅜” (9,52) NPT x ½” (12,70) ODS (for K65 pipe connection). For OCU‑CR and OCU‑CRC units.
PAW-CO2-RACORD-5/8
Racord ⅜” (9,52) NPT x ⅝” (15,88) ODS (for K65 pipe connection). For OCU‑CR and OCU‑CRC units.
PAW-CO2-RACORD-3/4
Racord, ⅜” (9,52) NPT x ¾” (19,05) ODS (for K65 pipe connection). For OCU‑CR and OCU‑CRC units.
Spare parts for service and maintenance (model-specific compatibility - see individual descriptions)
80203514142000
S-006T suction filter, ¾” (19,05) (outer Ø welding) for OCU‑CR400VF8(A) and OCU‑CRC060A08*.
* Sample image – actual product appearance may vary.
80203514139000 (1)
S-008T1 suction filter, ¾" (19,05) (outer Ø welding) for OCU‑CR1000VF8(A), OCU‑CR2000VF8A, OCU‑CRC150A08 and SCU-CRC150A08.
80203513180000 (2)
D-155T filter dryer, ⅝" (15,88) (in Ø welding) (type CO-085-S) for OCU‑CR1000VF8(A) and OCU‑CR2000VF8A.
80203513187000 (3)
DCY-P8 165 S filter dryer, ⅝" (16,10) (in Ø welding) for OCU‑CR1000VF8(A) and OCU‑CR2000VF8A.
80203513179000 (4)
D-152T filter dryer, ¼" (6,35) (in Ø welding) (type CO-082-S) for OCU‑CR200VF5A and OCU‑CR400VF8(A).
80203513190000
DCY‑P8 093S filter dryer, 3/8” (9,60) (in Ø welding) for OCU‑CR400VF8(A).
80203513186000 (5)
DCY-P12 092 S filter dryer, ¼" (6,40) (in Ø welding) for OCU‑CR200VF5A.
Compatibility relationship: (2) and (3) are compatible; (4) and (5) are compatible; (2) and (4) until end of stock.