3-Pipe ECOi EX MF4 Series - R32

3-Pipe ECOi EX MF4 Series · R32

Extreme efficiency, quality, compact.


* Panasonic’s internal research. 12HP model with 80m piping installation.

Technische Daten

Alles anzeigen
3-Pipe ECOi EX MF4 Series - R32 Dreiphasig
8 HP 10 HP
External static pressure Pa 80 80
EER (1) W/W 3,4 3,5
Input power cooling kW 6,43 7,92
Input power heating W 5,70 7,49
Current in cooling (1p 220V / 3p 380) A 11,2 13,4
Current in cooling (1p 230V / 3p 400) A 10,7 12,7
Current in cooling (1p 240V / 3p 415) A 10,3 12,2
Current in heating (1p 220V / 3p 380) A 10,1 12,7
Current in heating (1p 230V / 3p 400) A 9,57 12,1
Current in heating (1p 240V / 3p 415) A 9,23 11,6
SCOP (5) 4,32 4,35
Air flow m³/h 196 205
Spannungsversorgung (Hz) Hz 50 50
Starting current A 1,00 1,00
Piping diameter (Liquid) (2) Inch (mm) 3/8 (9,52) / 1/2 (12,70) 3/8 (9,52) / 1/2 (12,70)
Piping diameter (Balance) (2) Inch (mm) 1/4 (6,35) 1/4 (6,35)
Piping diameter (Gas) (2) Inch (mm) 5/8 (15,88) / 3/4 (19,05) 5/8 (15,88) / 3/4 (19,05)
Maximum allowable indoor / outdoor capacity ratio (3) % 50 ~ 150 50 ~ 150
Vorgefüllte Kältemittellänge (R32) / CO2 - Äquivalent kg / T 8,10 / 5,47 8,80 / 5,94
Außentemperatur - Grenzwerte Kühlen (min.) °C -10 -10
Nennkühlleistung kW 22,4 28,0
Nennheizleistung kW 25,0 31,5
Net weight kg 217 218
Außengerät U-8MF4E8 U-10MF4E8
Außentemperatur - Grenzwerte Kühlen (max.) °C +52 +52
Außentemperatur - Grenzwerte Heizen (min.) °C -20 -20
Außentemperatur - Grenzwerte Heizen (max.) °C +18 +18
COP (1) W/W 4,3 4,2
Dimension (Height) mm 1,660 1,660
Dimension (Width) mm 880 880
Dimension (Depth) mm 765 765
Spannungsversorgung (V) V 380 - 400 - 415 380 - 400 - 415
Spannungsversorgung (ph) Dreiphasig Dreiphasig

1) EER and COP calculation is based in accordance to EN 14511.
2) Piping diameter under 100m for ultimate indoor unit / over 100m for ultimate indoor unit (if the longest piping equivalent length exceeds 100m, increase the sizes of the main tubes by 1 rank for gas tubes and liquid tubes).
3) If the following conditions are satisfied, the effective range is above 130% and below 200%: A. Obey the limited number of connectable indoor units. B. The lower limit of operating range for heating outdoor temperature is limited to -10°C WB (standard -25°C WB). C. Simultaneous operation is limited to less than 130% of connectable indoor units.
4) SEER / SCOP and ηs,c / ηs,h are in accordance with ErP test data for U2 type 4 way 90x90 cassette indoor units.
5) SEER / SCOP is calculated based on the seasonal space cooling / heating efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.