| Outdoor unit (Connected air to air indoor units) |
CU-4WZ90CBE5 (1 (S-71WF3E))
|
CU-4WZ90CBE5 (2 ~ 3)
|
| Indoor nominal capacity (Min ~ Max) |
kW |
– ~ 7,10 kW
|
3,20 ~ 11,00 kW
|
| Nennkühlleistung |
kW |
7,10
|
9,00
|
| Nennkühlleistung (min.) |
kW |
1,60
|
1,60
|
| Nennkühlleistung (max.) |
kW |
9,00
|
10,20
|
| Nenn-EER (1) |
W/W |
3,40
|
3,83
|
| Nenn-EER (1) (min.) |
W/W |
3,40
|
4,00
|
| Nenn-EER (1) (max.) |
W/W |
2,57
|
3,00
|
| SEER (2) |
5,60 A+
|
7,00 A++
|
| Auslegungslast Kühlen |
kW |
7,10
|
9,00
|
| Nennleistungsaufnahme Kühlen |
kW |
2,09
|
2,35
|
| Nennleistungsaufnahme Kühlen (min.) |
kW |
0,47
|
0,40
|
| Nennleistungsaufnahme Kühlen (max.) |
kW |
3,50
|
3,40
|
| Annual energy consumption cooling (3) |
kWh/a |
444
|
450
|
| Nennheizleistung |
kW |
7,10
|
9,50
|
| Nennheizleistung (min.) |
kW |
2,00
|
2,00
|
| Nennheizleistung (max.) |
kW |
10,20
|
12,00
|
| Nenn-COP (1) |
W/W |
3,90
|
4,30
|
| Nenn-COP (1) (min.) |
W/W |
4,65
|
5,56
|
| Nenn-COP (1) (max.) |
W/W |
3,00
|
3,64
|
| SCOP (2) |
3,90 A
|
4,60 A++
|
| Auslegungslast Heizen bei -10°C |
kW |
5,80
|
6,50
|
| Nennleistungsaufnahme Heizen |
kW |
1,82
|
2,21
|
| Nennleistungsaufnahme Heizen (min.) |
kW |
0,43
|
0,36
|
| Nennleistungsaufnahme Heizen (max.) |
kW |
3,40
|
3,30
|
| Annual energy consumption heating (3) |
kWh/a |
2.082
|
1,978
|
| Current cooling |
A |
10,1
|
11,2
|
| Current heating |
A |
8,7
|
10,6
|
| Stromversorgung |
V |
230
|
230
|
| Outdoor sound pressure (Cool - air to air) (4) |
dB(A) |
49
|
53
|
| Outdoor sound pressure (Heat - air to air) (4) |
dB(A) |
49
|
55
|
| Outdoor sound power (Cool - air to air) (4) |
dB(A) |
68
|
69
|
| Outdoor sound power (Heat - air to air) (4) |
db(A) |
67
|
70
|
| Abmessung (H) |
mm |
999
|
999
|
| Outdoor dimension (Width) |
mm |
940
|
940
|
| Outdoor dimension (Depth) |
mm |
340
|
340
|
| Nettogewicht |
kg |
83
|
83
|
| Pipe diameter (Liquid) |
Inch (mm) |
1/4 (6,35)
|
1/4 (6,35)
|
| Pipe diameter (Gas) |
Inch (mm) |
3/8 (9,52)
|
3/8 (9,52)
|
| Maximum Total Piping Length |
70
|
80
|
| Pipe length range to one unit |
m |
3 ~ 35
|
3 ~ 25
|
| Höhenunterschied IG/AG |
m |
30
|
20
|
| Pipe length for additional gas |
m |
30
|
30
|
| Additional gas amount |
g/m |
25
|
25
|
| Vorgefüllte Kältemittellänge (R32) / CO2 - Äquivalent |
kg / T |
2,58 / 1,74
|
2,58 / 1,74
|
| Operating range (Heat - air to air) |
°C |
-15 ~ +24
|
-25 ~ +24
|
| Operating range (Cool - air to air) |
°C |
-10 ~ +46
|
-10 ~ +46
|
| Operating range (Heat - air to water) |
°C |
-15 ~ +35
|
-25 ~ +35
|
| Operating range (Heat recovery - floor / DHW) |
°C |
+10 ~ +35 / +10 ~ +46
|
+10 ~ +35 / +10 ~ +46
|