Hydraulic Split All in One 185L DHW tank L Series 1 phase · R290

Aquarea High Performance Hydraulic Split All in One 185l DHW tank L Series

A revolution in design, efficiency, connectivity and sustainability.
Aquarea L Generation is engineered with industry leading R290 natural refrigerant with GWP 0,02. It is the perfect solution for renovations, where a high water outlet temperature is required or homes looking for avant-garde heat pump with natural refrigerant.
Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.
A premium white, faithful to the Aquarea spirit underlined by the seamlessly integrated controller which provides a sleek black band across the unit. The All in One model maintains its compactness with its encroachment of only 599 x 602mm, comparable to a household appliance.
The outdoor units, with an Anthracite Grey colour which will dress the entire range, have been completely redesigned with an innovative design that will find its place in all spaces.

Further comfort and peace of mind with Aquarea

Technische Daten

Alles anzeigen
Hydraulic Split All in One 185L DHW tank L Series 1 phase · R290 Einphasig
5 kW 7 kW 9 kW
Kit 3kW electric heater WH-WDG05LE5 + WH-ADC0509L3E5 WH-WDG07LE5 + WH-ADC0509L3E5 WH-WDG09LE5 + WH-ADC0509L3E5
Kit 6kW electric heater WH-WDG05LE5 + WH-ADC0509L6E5 WH-WDG07LE5 + WH-ADC0509L6E5 WH-WDG09LE5 + WH-ADC0509L6E5
Heizleistung (A +7°C, W 35°C) kW 5 7 9
COP (A +7°C, W 35°C) 5,05 4,93 4,55
Heizleistung (A +7°C, W 55°C) kW 5 7 8,9
COP (A +7°C, W 55°C) 3,07 2,98 3,03
Heizleistung (A +2°C, W 35°C) kW 5 6,85 7
COP (A +2°C, W 35°C) 3,52 3,43 3,41
Heizleistung (A +2°C, W 55°C) kW 5 6,25 7
COP (A +2°C, W 55°C) 2,34 2,34 2,41
Heizleistung (A -7°C, W 35°C) kW 5 5,8 7
COP (A -7°C, W 35°C) 3,01 3,01 2,8
Heating capacity (A -7°C, W 55°C) kW 5 5,8 7
COP (A -7°C, W 55°C) 2,12 2,12 2,13
Kühlleistung (A 35°C, W 7°C) kW 5 7 8,2
EER (A 35°C, W 7°C) 3,23 3,03 2,82
Kühlleistung (A 35°C, W 18°C) kW 5 7 9
EER (A 35°C, W 18°C) 5 4,73 4,19
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 5,06 / 3,63 4,96 / 3,62 4,84 / 3,67
Mittleres Klima. Raumheizungs-Energieeffizienz (W 35°C / W 55°C) ηs % 200 / 142 195 / 142 190 / 144
Mittleres Klima. Raumheizungs-Energieeffizienzklasse (W 35°C / W 55°C) (1) A+++ to D A+++ / A++ A+++ / A++ A+++ / A++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,00 / 4,27 6,31 / 4,52 6,44 / 4,50
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 237 / 168 249 / 178 255 / 177
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++ A+++ / A+++ A+++ / A+++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,25 / 3,28 4,25 / 3,29 4,31 / 3,33
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 167 / 128 167 / 129 170 / 130
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A++ A++ / A++ A++ / A++
Indoor unit 3kW electric heater WH-ADC0509L3E5 WH-ADC0509L3E5 WH-ADC0509L3E5
Indoor unit 6kW electric heater WH-ADC0509L6E5 WH-ADC0509L6E5 WH-ADC0509L6E5
Indoor sound pressure (Heat) dB(A) 28 28 28
Indoor sound pressure (Cool) dB(A) 28 28 28
Abmessung (H) mm 1 642 1 642 1 642
Abmessung (B) mm 599 599 599
Abmessung (T) mm 602 602 602
Nettogewicht kg 93 (3 kW) / 94 (6 kW) 93 (3 kW) / 94 (6 kW) 93 (3 kW) / 94 (6 kW)
Water pipe connector Inch 101 (3 kW) / — (6 kW) 101 (3 kW) / — (6 kW) 101 (3 kW) / — (6 kW)
Water pipe connector (room) Inch 11⁄4 11⁄4 11⁄4
Water pipe connector (shower) Inch 3⁄4 3⁄4 3⁄4
Hocheffizienzpumpe (Drehzahlstufen) Variable Geschwindigkeit Variable Geschwindigkeit Variable Geschwindigkeit
Hocheffizienzpumpe (Leistungsaufnahme min.) W 30 30 30
Hocheffizienzpumpe (Leistungsaufnahme max.) W 145 145 145
Warmwasservolumenstrom (∆T=5 K. 35°C) L/min 14,3 (3 kW) / 25,8 (6 kW) 14,3 (3 kW) / 25,8 (6 kW) 14,3 (3 kW) / 25,8 (6 kW)
Speichervolumen L 185 185 185
Max. Brauchwarmwassertemperatur °C 65 65 65
Material der Speicherinnenseite Edelstahl Edelstahl Edelstahl
Lastprofil gem. EN16147 L L L
DHW tank ERP average climate efficiency rating (2) A+ to F A+ A+ A+
DHW tank ERP warm climate efficiency rating (2) A+ to F A+ A+ A+
DHW tank ERP cold climate efficiency rating (2) A+ to F A A A
Warmwasserbereitungs-Energieeffizienz ηwh % 148 148 148
DHW tank ERP average climate COPdHW COPdHW 3,61 3,61 3,61
Warmwasserbereitungs-Energieeffizienz η ηwh % 160 160 160
DHW tank ERP warm climate COPdHW COPdHW 4 4 4
Kaltwasserbereitungs-Energieeffizienz η ηwh % 112 112 112
DHW tank ERP cold climate COPdHW COPdHW 2,8 2,8 2,8
Außengerät WH-WDG05LE5 WH-WDG07LE5 WH-WDG09LE5
Outdoor sound power (Heat) (3) dB(A) 52 53 54
Abmessung (H) mm 996 996 996
Outdoor dimension (Width) mm 980 980 980
Outdoor dimension (Depth) mm 430 430 430
Nettogewicht kg 98 98 97
Refrigerant (R290) / CO2 Eq. kg / T 0,96 / 0,00002 0,96 / 0,00002 1,00 / 0,00002
Water pipe connector (indoor units) Inch 1 1 1
Water pipe connector (outdoor units) Inch 1 1 1
Pipe length range standard m 5 5 5
Pipe length range maximum m 30 30 30
Höhenunterschied IG/AG m 10 10 10
Operation range - Outdoor ambient (Heat) °C -25 ~ +35 -25 ~ +35 -25 ~ +35
Operation range - Outdoor ambient (Cool) °C +10 ~ +43 +10 ~ +43 +10 ~ +43
Wasseraustrittstemperatur (Heizen) °C 20 ~ 75 20 ~ 75 20 ~ 75
Wasseraustrittstemperatur (Kühlen) °C 5 ~ 20 5 ~ 20 5 ~ 20
Electrical information 3kW – 6kW 3kW – 6kW 3kW – 6kW
Electric backup heater (3kW — 6kW) kW 3,00 – 6,00 3,00 – 6,00 3,00 – 6,00
Recommended RCD, supply 1 (3kW — 6kW) A 25 – 25 25 – 25 25 – 25
Recommended RCD, supply 2 (3kW — 6kW) A 16 – 30 16 – 30 16 – 30
Recommended minimum cable size, supply 1 (3kW — 6kW) (4) mm² 3x2,5 — 3x2,5 3x2,5 — 3x2,5 3x2,5 — 3x2,5
Recommended minimum cable size, supply 2 (3kW — 6kW) (4) mm² 3x1,5 — 3x4,0 3x1,5 — 3x4,0 3x1,5 — 3x4,0
(1) Skala von A+++ bis D.
(2) Skala von A+ bis F.
(3) Der Schallleistungspegel wird gemäß EN12102 unter den Bedingungen der EN14825 (Teillast) gemessen.
(4) Prüfen Sie die örtlichen Vorschriften.
* Die Berechnung von EER und COP basiert auf der Norm EN14511.
** Dieses Produkt entspricht der europäischen Wasserqualitätsrichtlinie 98/83/EG, geändert durch 2015/1787/EU. Die Lebensdauer des Produkts wird nicht garantiert, wenn Grundwasser wie Quell- oder Brunnenwasser oder Leitungswasser mit Salz oder anderen Verunreinigungen verwendet wird oder in Gebieten mit saurer Wasserqualität. Die Wartungs- und Garantiekosten in diesen Fällen liegen in der Verantwortung des Kunden.

Zubehör