Modelle
Aquarea High Performance All in One 185L DHW tank K Series 1 phase · R32
A revolution in design, efficiency, connectivity and sustainability.Aquarea K Series is a ground breaking low-energy system for heating, cooling and domestic hot water production that delivers outstanding performance. This model is ideal for new installations and well-insulated homes.
Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.
A premium white, faithful to the Aquarea spirit underlined by the seamlessly integrated controller which provides a sleek black band across the unit. The All in One model maintains its compactness with its encroachment of only 598 x 600mm, comparable to a household appliance.
The outdoor units, with an Anthracite Grey colour which will dress the entire range, have been completely redesigned with an innovative design that will find its place in all spaces.
- COP bis zu 5,33
- A+++ für Heizung bei 35°C und A+ für Warmwasser
- Wasserpumpe "A" mit variabler Drehzahl
- Warmwasserspeicher aus Edelstahl mit U-Vacua™-Isolierplatte
- COP für Warmwasser bis zu 3,50
- Eingebauter magnetischer Wasserfilter
- Betrieb ohne Heizungsunterstützung bei -25°C
- 60°C warmes Wasser auch bei -10°C Außentemperatur
- Optimierte Benutzeroberfläche und verbesserte Funktionen
- Optionale Aquarea Smart und Service Cloud und Integration in BMS-Projekte
Further comfort and peace of mind with Aquarea
Technische Daten
| All in One 185L DHW tank K Series 1 phase · R32 | Einphasig | |||
|---|---|---|---|---|
| 12 kW | 16 kW | |||
| Heizleistung (A +7°C, W 35°C) | kW | 12,10 | 16,00 | |
| COP (A +7°C, W 35°C) | 4,78 | 4,31 | ||
| Heizleistung (A +2°C, W 35°C) | kW | 11,50 | 13,00 | |
| COP (A +2°C, W 35°C) | 3,44 | 3,18 | ||
| Heizleistung (A -7°C, W 35°C) | kW | 10,10 | 11,70 | |
| COP (A -7°C, W 35°C) | 2,74 | 2,61 | ||
| Kühlleistung (A 35°C, W 7°C) | kW | 10,70 | 12,20 | |
| EER (A 35°C, W 7°C) | 2,68 | 2,68 | ||
| Leitungslänge (min. / max.) | m | 3 ~ 30 (3 ~ 50) (5) | 3 ~ 30 (3 ~ 50) 5) | |
| Abmessung (H) | mm | 1.642 | 1 .642 | |
| Nettogewicht | kg | 101 (6 kW) | 101 (6 kW) | |
| Abmessung (H) | mm | 1.340 | 1. 340 | |
| Nettogewicht | kg | 88 | 88 | |
| Indoor sound pressure (Heat) | dB(A) | 33 | 33 | |
| Vorgefüllte Kältemittellänge (R32) / CO2 - Äquivalent | kg / T | 1,6 / 1.080 | 1,6 / 1.080 | |
| Abmessung (B) | mm | 599 | 599 | |
| Abmessung (T) | mm | 602 | 602 | |
| Flüssigkeitsleitung | Inch (mm) | 1/4 (6,35) | 1/4 (6,35) | |
| Sauggasleitung | Inch (mm) | 1/2 (12,7) | 5/8 (15,88) | |
| Pipe length for additional gas | m | 10 | 10 | |
| Additional gas amount | g/m | 30 | 30 | |
| Außengerät | WH-UDZ12KE5 | WH-UDZ16KE5 | ||
| Heizleistung (A +7°C, W 55°C) | kW | 12,00 | 14,70 | |
| COP (A +7°C, W 55°C) | 2,96 | 2,72 | ||
| Heizleistung (A +2°C, W 55°C) | kW | 9,20 | 10,00 | |
| COP (A +2°C, W 55°C) | 2,25 | 2,24 | ||
| Heating capacity (A -7°C, W 55°C) | kW | 8,40 | 9,10 | |
| COP (A -7°C, W 55°C) | 1,97 | 1,85 | ||
| Kühlleistung (A 35°C, W 18°C) | kW | 10,70 | 13,00 | |
| EER (A 35°C, W 18°C) | 3,92 | 3,80 | ||
| Mittleres Klima. Raumheizungs-Energieeffizienz (W 35°C / W 55°C) | ηs % | 180 / 130 | 176 / 133 | |
| Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 4,58 / 3,33 | 4,46 / 3,40 | |
| Mittleres Klima. Raumheizungs-Energieeffizienzklasse (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A++ | A+++ / A++ | |
| Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 256 / 171 | 245 / 169 | |
| Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 6,47 / 4,34 | 6,20 / 4,30 | |
| Heating warm climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A+++ | A+++ / A+++ | |
| Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 169 / 127 | 168 / 121 | |
| Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 4,31 / 3,26 | 4,28 / 3,10 | |
| Heating cold climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A++ / A++ | A++ / A+ | |
| Indoor sound pressure (Cool) | dB(A) | 33 | 33 | |
| Water pipe connector | Inch | R 11⁄4 | R11⁄4 | |
| Hocheffizienzpumpe (Drehzahlstufen) | Variable Geschwindigkeit | Variable Geschwindigkeit | ||
| Warmwasservolumenstrom (∆T=5 K. 35°C) | L/min | 34,4 | 45,8 | |
| Speichervolumen | L | 185 | 185 | |
| Max. Brauchwarmwassertemperatur | °C | 65 | 65 | |
| Material der Speicherinnenseite | Edelstahl | Edelstahl | ||
| Lastprofil gem. EN16147 | L | L | ||
| DHW tank ERP average climate efficiency rating (2) | A+ to F | A+ | A+ | |
| DHW tank ERP warm climate efficiency rating (2) | A+ to F | A | A | |
| DHW tank ERP cold climate efficiency rating (2) | A+ to F | A | A | |
| Warmwasserbereitungs-Energieeffizienz | ηwh % | 100 | 100 | |
| Warmwasserbereitungs-Energieeffizienz η | ηwh % | 116 | 116 | |
| Kaltwasserbereitungs-Energieeffizienz η | ηwh % | 80 | 80 | |
| Outdoor dimension (Width) | mm | 900 | 900 | |
| Outdoor dimension (Depth) | mm | 320 | 320 | |
| Höhenunterschied IG/AG | m | 20 (30) (5) | 20 (30) 5) | |
| Operation range - Outdoor ambient (Heat) | °C | -25 ~ +35 | -25 ~ +35 | |
| Operation range - Outdoor ambient (Cool) | °C | +10 ~ +43 | +10 ~ +43 | |
| DHW tank ERP average climate COPdHW | COPdHW | 2,50 | 2,50 | |
| DHW tank ERP warm climate COPdHW | COPdHW | 2,90 | 2,90 | |
| DHW tank ERP cold climate COPdHW | COPdHW | 2,00 | 2,00 | |
| Outdoor sound power (Heat) (3) | dB(A) | 65 | 65 | |
| Kit 6kW electric heater | KIT-ADC12K6E5 | KIT-ADC16K6E5 | ||
| Indoor unit 6kW electric heater | WH-ADC0912K6E5 | WH-ADC16K6E5 | ||
| Electrical information | 6 kW | 6 kW | ||
| Electric backup heater | kW | 6,00 | 6,00 | |
| Recommended fuse | A | 30 / 30 | 30 / 30 | |
(2) Skala von A+ bis F.
(3) Schallleistung in Übereinstimmung mit 811/2013, 813/2013 und EN12102-1:2017 bei +7°C.
(4) Betriebsbereich bis zu -25°C bei Heizung mit 3 ~ 40m Rohrlänge, Betriebsbereich bis zu -15°C bei Heizung mit 3 ~ 50m Rohrlänge.
(5) Prüfen Sie die örtlichen Vorschriften.
* Die Berechnung von EER und COP basiert auf der Norm EN14511.
** Dieses Produkt entspricht der europäischen Wasserqualitätsrichtlinie 98/83/EG, geändert durch 2015/1787/EU. Die Lebensdauer des Produkts wird nicht garantiert, wenn Grundwasser wie Quell- oder Brunnenwasser oder Leitungswasser mit Salz oder anderen Verunreinigungen verwendet wird oder wenn die Wasserqualität sauer ist. Die Wartungs- und Garantiekosten in diesen Fällen liegen in der Verantwortung des Kunden.